Short-term safety and efficacy of a novel high tibial osteotomy system: a case controlled study

被引:30
作者
Getgood, Alan [1 ]
Collins, Brett [1 ]
Slynarski, Konrad [2 ]
Kurowska, Emilia [2 ]
Parker, David [3 ]
Engebretsen, Lars [4 ]
MacDonald, Peter B. [5 ]
Litchfield, Robert [1 ]
机构
[1] Univ Western Ontario, Ctr 3M, Fowler Kennedy Sport Med Clin, London, ON, Canada
[2] Sports Med Ctr CMS, Warsaw, Poland
[3] Sydney Orthopaed Res Inst, Sydney, NSW, Australia
[4] Univ Oslo, Dept Orthopaed Surg, Oslo, Norway
[5] Univ Manitoba, Sect Orthopaed, Pan Am Clin, Winnipeg, MB, Canada
关键词
iBalance; High tibial osteotomy; Open wedge; MEDIAL COMPARTMENT ARTHRITIS; PUDDU PLATE; CLOSING-WEDGE; GONARTHROSIS; STABILITY; FIXATION; TOMOFIX; 2-YEAR; KNEE;
D O I
10.1007/s00167-011-1709-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To evaluate the safety and efficacy of the novel iBalance Medial Opening Wedge High Tibial Osteotomy (HTO) system in executing lower limb realignment in patients with symptomatic varus gonarthrosis. A multicentre case series of iBalance medial opening wedge HTO was compared to an historic case-matched control series of HTO's performed using another implant. Subjects were prospectively observed at 3, 6 and 12 months after surgery. Primary endpoints included the reporting of adverse events, weight-bearing status without pain and radiographic evidence of bony union. Secondary endpoints included maintenance of osteotomy correction angle, patient reported outcome (KOOS and SF-36) and gait analysis. Thirty-two consecutive patients were included in the iBalance group (mean age 49.7, 30-67; M:F, 20:12), paired with 32 control subjects (49.8, 35-66; 21:11). Three patients (9.4%) in the iBalance group experienced a complication requiring intervention versus one patient (3.1%) in the control group. No statistically significant differences were seen between groups in terms of time to weight bearing, radiographic union, implant stability or patient reported outcome. Gait analysis revealed a statistically significant reduction in knee external adduction moment (P < 0.001). The iBalance medial opening wedge HTO system has been shown to be a safe, novel implant for use in proximal tibial osteotomy. This study shows that the iBalance medial opening wedge HTO system has an equivalent short-term safety and efficacy profile to the 2nd generation Puddu system.
引用
收藏
页码:260 / 269
页数:10
相关论文
共 23 条
[1]   Results of high tibial osteotomy: review of the literature [J].
Amendola, Annunziato ;
Bonasia, Davide Edoardo .
INTERNATIONAL ORTHOPAEDICS, 2010, 34 (02) :155-160
[2]   High tibial osteotomy with Puddu plate for the treatment of varus gonarthrosis [J].
Asik, Mehmet ;
Sen, Cengiz ;
Kilic, Bulent ;
Goksan, S. Bora ;
Ciftci, Feyyaz ;
Taser, Omer F. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (10) :948-954
[3]   Comparative Testing by Cyclic Loading of Rotator Cuff Suture Anchors Containing Multiple High-Strength Sutures [J].
Barber, F. Alan ;
Hapa, Onur ;
Bynum, James A. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (09) :S134-S141
[4]   Medial Opening Wedge High Tibial Osteotomy: A Prospective Cohort Study of Gait, Radiographic, and Patient-Reported Outcomes [J].
Birmingham, Trevor B. ;
Giffin, J. Robert ;
Chesworth, Bert M. ;
Bryant, Dianne M. ;
Litchfield, Robert B. ;
Willits, Kevin ;
Jenkyn, Thomas R. ;
Fowler, Peter J. .
ARTHRITIS & RHEUMATISM-ARTHRITIS CARE & RESEARCH, 2009, 61 (05) :648-657
[5]   Early full weight bearing is safe in open-wedge high tibial osteotomy [J].
Brinkman, Justus-Martijn ;
Luites, Joan W. H. ;
Wymenga, Ate B. ;
van Heerwaarden, Ronald J. .
ACTA ORTHOPAEDICA, 2010, 81 (02) :193-198
[6]   Osteotomy for medial compartment arthritis of the knee using a closing wedge or an opening wedge controlled by a Puddu plate - A one-year randomised, controlled study [J].
Brouwer, R. W. ;
Bierma-Zeinstra, S. M. A. ;
van Raaij, T. M. ;
Verhaar, J. A. N. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (11) :1454-1459
[7]   Efficacy of anterior cervical fusion: Comparison of titanium cages, polyetheretherketone (PEEK) cages and autogenous bone grafts [J].
Chou, Yu-Cheng ;
Chen, Der-Cherng ;
Hsieh, Wanhua Annie ;
Chen, Wu-Fu ;
Yen, Pao-Sheng ;
Harnod, Tomor ;
Chiou, Tsung-Lang ;
Chang, Yuh-Lin ;
Su, Chain-Fa ;
Lin, Shinn-Zong ;
Chen, Shin-Yuan .
JOURNAL OF CLINICAL NEUROSCIENCE, 2008, 15 (11) :1240-1245
[8]  
COVENTRY MB, 1979, ORTHOP CLIN N AM, V10, P191
[9]  
DUGDALE TW, 1992, CLIN ORTHOP RELAT R, P248
[10]  
Hunt MA, 2006, CAN J SURG, V49, P401