Simple determination of aflatoxins in rice by ultra-high performance liquid chromatography coupled to chemical post-column derivatization and fluorescence detection

被引:51
|
作者
Fernando Huertas-Perez, Jose [1 ]
Arroyo-Manzanares, Natalia [1 ]
Hitzler, Dominik [1 ]
German Castro-Guerrero, Francisco [1 ]
Gamiz-Gracia, Laura [1 ]
Garcia-Campana, Ana M. [1 ]
机构
[1] Univ Granada, Fac Sci, Dept Analyt Chem, Campus Fuentenueva S-N, E-18071 Granada, Spain
关键词
Aflatoxins; Fluorescence detection; Liquid chromatography; Post-column derivatization; Rice; IMMUNOAFFINITY COLUMN CLEANUP; CATTLE FEED; METHODOLOGY; MYCOTOXINS; B-1; WORLDWIDE; CHEESE; MILK; M-1;
D O I
10.1016/j.foodchem.2017.10.041
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A fast and simple analytical method was developed and characterized for the determination of aflatoxins (B-1, B-2, G(1) and G(2)) in rice. The procedure is based on a simple solid-liquid extraction without further clean-up, and analysis by ultra-high performance liquid chromatography coupled with fluorescence detection. Fluorescence emission of aflatoxins B-1 and G(1) was enhanced by post-column chemical derivatization using pyridinium bromide perbromide. The analytical method was satisfactorily characterized in white and brown rice. Under optimum conditions, external calibration in solvent could be used for quantification purposes and limits of quantification were below the maximum contents established by the European Union regulation for these contaminants/commodity group combination (0.07-0.14 mu g/kg for white rice and 0.20-0.28 mu g/kg for brown rice). Recovery studies carried out at three different concentration levels (0.5, 2 and 5 mu g/kg) showed values in the range of 84.5-105.3%, and RSDs= 5%.
引用
收藏
页码:189 / 195
页数:7
相关论文
共 50 条
  • [21] Simultaneous determination of furathiocarb and metabolites in biological tissues high-performance liquid chromatography and post-column derivatization
    Liu, KH
    Byoun, JY
    Sung, HJ
    Lee, HK
    Kim, K
    Lee, HS
    Kim, JH
    CHROMATOGRAPHIA, 2001, 53 (11-12) : 687 - 690
  • [22] Simultaneous determination of furathiocarb and metabolites in biological tissues by high-performance liquid chromatography and post-column derivatization
    K. H. Liu
    J. Y. Byoun
    H. J. Sung
    H. K. Lee
    K. Kim
    H. S. Lee
    J. H. Kim
    Chromatographia, 2001, 53 : 687 - 690
  • [23] Geometrically deformed tubes as efficient vessels for post-column derivatization in high-performance liquid chromatography
    Neue, Uwe Dieter
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2010, 49 (07) : 662 - 671
  • [24] Luminescent determination of quinolones in milk samples by liquid chromatography/post-column derivatization with terbium oxide nanoparticles
    Yanez-Jacome, G. S.
    Aguilar-Caballos, M. P.
    Gomez-Hens, A.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1405 : 126 - 132
  • [25] Liquid chromatography on an amide stationary phase with post-column derivatization and fluorimetric detection for the determination of streptomycin and dihydrostreptomycin in foods
    Vinas, Pilar
    Balsalobre, Nuria
    Hernandez-Cordoba, Manuel
    TALANTA, 2007, 72 (02) : 808 - 812
  • [26] A comprehensive review of liquid chromatography hyphenated to post-column photoinduced fluorescence detection system for determination of analytes
    Muhammad, Nadeem
    Hussian, Irshad
    Ali, Amjad
    Hussain, Tajamal
    Intisar, Azeem
    Ul Haq, Iftikhar
    Subhani, Qamar
    Hedar, Mateen
    Zhong, Jia-Lun
    Asif, Muhammad
    Guo, Dandan
    Hairong, Cui
    Zhu, Yan
    ARABIAN JOURNAL OF CHEMISTRY, 2022, 15 (09)
  • [27] Immunoaffinity column clean-up and liquid chromatography with post-column derivatization for analysis of aflatoxins in traditional Chinese medicine
    Yang, MH
    Chen, JM
    Zhang, XH
    CHROMATOGRAPHIA, 2005, 62 (9-10) : 499 - 504
  • [28] High performance liquid chromatography of disaccharides on a porous graphitic carbon column applying post-column derivatization with benzamidine
    Koimur, M
    Lu, B
    Westerlund, D
    CHROMATOGRAPHIA, 1996, 43 (5-6) : 254 - 260
  • [29] Determination of Aflatoxins in Red Pepper and Kimchi by Ultra-High-Performance Liquid Chromatography with Fluorescence Detection
    Kim, Su-Ji
    Cheon, Seon-Hwa
    Kim, Sung Hyun
    Seo, Hye-Young
    ANALYTICAL LETTERS, 2020, 53 (07) : 1087 - 1096
  • [30] Immunoaffinity Column Clean-Up and Liquid Chromatography with Post-Column Derivatization for Analysis of Aflatoxins in Traditional Chinese Medicine
    Mei-Hua Yang
    Jian-Min Chen
    Xue-Hui Zhang
    Chromatographia, 2005, 62 : 499 - 504