The optimised CO-rebreathing method: a new tool to determine total haemoglobin mass routinely

被引:363
作者
Schmidt, W [1 ]
Prommer, N [1 ]
机构
[1] Univ Bayreuth, Dept Sports Med & Sports Physiol, D-95440 Bayreuth, Germany
关键词
carbonmonoxide; carboxyhaemoglobin; mixing time; myoglobin; HbCO half-time;
D O I
10.1007/s00421-005-0050-3
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
A routine method to determine total haemoglobin mass (tHb) in clinical practice and sports medicine is non-existent. Radioactive tracers or other dilution procedures like the common CO-rebreathing method (Proc(com)) are impractical, the latter in particular because of the relatively long time of respiration. According to the multicompartment model of Bruce and Bruce (J Appl Physiol 95:1235-1247, 2003) the respiration time can be considerably reduced by inhaling a CO-bolus instead of the commonly used gas mixture. The aim of this study was to evaluate this theoretical concept in practice. The kinetics of the HbCO formation were compared in arterialised blood sampled from an hyperaemic earlobe after inhaling a CO-bolus (Proc(new)) for 2 min and a CO-O-2 mixture (Proc(com)) for similar to 10 min. The reliability of Proc(new) was checked in three consecutive tests, and phlebotomy was used to determine the validity. VO2max was determined with and without previous application of Proc(new) and the half-time of HbCO was registered also in arterialised blood after resting quietly and after the VO2max test. Proc(new) yielded virtual identical tHb values compared to Proc(com) when HbCO determined 5 min after starting CO-rebreathing was used for calculation. The typical error of Proc(new) was 1.7%, corresponding to a limit of agreement (95%) of 3.3%. The loss of 95 g (19) haemoglobin was detected with an accuracy of 9 g (12). After application of Proc(new) VO2max was reduced by 3.0% (3.7) (P=0.022) and half-time was lowered from 132 min (77) to 89 min (23) after the VO2max test. Inhaling a CO-bolus markedly simplifies the CO-rebreathing method without reducing validity and reliability and can be used for routine determination of tHb for various indications.
引用
收藏
页码:486 / 495
页数:10
相关论文
共 43 条
[1]  
Arnold HR, 1921, AM J PHYSIOL, V56, P313, DOI 10.1152/ajplegacy.1921.56.2.313
[2]   Live high, train low does not change the total haemoglobin mass of male endurance athletes sleeping at a simulated altitude of 3000 m for 23 nights [J].
Ashenden, MJ ;
Gore, CJ ;
Dobson, GP ;
Hahn, AG .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1999, 80 (05) :479-484
[3]   Blood volume measurement - The next intraoperative monitor? [J].
Barker, SJ .
ANESTHESIOLOGY, 1998, 89 (06) :1310-1312
[4]  
Barnett K, 1998, BRIT J BIOMED SCI, V55, P123
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Hemoglobin mass and peak oxygen uptake in untrained and trained residents of moderate altitude [J].
Böning, D ;
Rojas, J ;
Serrato, M ;
Ulloa, C ;
Coy, L ;
Mora, M ;
Gomez, J ;
Hütler, M .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2001, 22 (08) :572-578
[7]   A multicompartment model of carboxyhemoglobin and carboxymyoglobin responses to inhalation of carbon monoxide [J].
Bruce, EN ;
Bruce, MC .
JOURNAL OF APPLIED PHYSIOLOGY, 2003, 95 (03) :1235-1247
[8]   DETERMINATION OF HEMOGLOBIN MASS AND BLOOD-VOLUME WITH CO - EVALUATION AND APPLICATION OF A METHOD [J].
BURGE, CM ;
SKINNER, SL .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 79 (02) :623-631
[9]  
Douglas CG, 1912, J PHYSIOL-LONDON, V44, P275
[10]   METABOLISM OF THE HEMIN CHROMOPROTEINS [J].
DRABKIN, DL .
PHYSIOLOGICAL REVIEWS, 1951, 31 (04) :345-431