Batch injection analysis with amperometric detection: application for simultaneous analysis using a single working electrode

被引:55
作者
Bezerra da Silva, Rodrigo Amorim [1 ]
Gimenes, Denise Tofanello [1 ]
Tormin, Thiago Faria [1 ]
Abarza Munoz, Rodrigo Alejandro [1 ]
Richter, Eduardo Mathias [1 ]
机构
[1] Univ Fed Uberlandia, Inst Quim, BR-38400902 Uberlandia, MG, Brazil
关键词
ANODIC-STRIPPING VOLTAMMETRY; TRACE-METALS; ANTIOXIDANTS; PARACETAMOL; DIPYRONE; SYSTEM;
D O I
10.1039/c1ay05395g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, we describe for the first time the association of batch injection analysis (BIA) with dual pulse amperometric (DPA) detection for simultaneous determination of multi-analytes using a single working electrode. The sequence of pulses is selected in such a way that the analytes are detected individually and independently at the same working unmodified electrode (using a correction factor). BIA provides fast response (high-throughput analysis), elevated precision, reduction of sample volumes and minimization of waste. To illustrate the potential of this method, BIA-DPA was applied for the simultaneous determination of biodiesel preservatives (tert-butylhydroquinone and butylated hydroxyanisole) and pharmaceutical compounds (paracetamol and caffeine or dipyrone and caffeine).
引用
收藏
页码:2804 / 2808
页数:5
相关论文
共 23 条
[1]   Anodic stripping voltammetry of trace metals by batch injection analysis [J].
Brett, CMA ;
Brett, AMO ;
Tugulea, L .
ANALYTICA CHIMICA ACTA, 1996, 322 (03) :151-157
[2]  
Brett CMA, 2000, J APPL TOXICOL, V20, P477, DOI 10.1002/1099-1263(200011/12)20:6<477::AID-JAT720>3.0.CO
[3]  
2-D
[4]   AMPEROMETRIC BATCH INJECTION-ANALYSIS - THEORETICAL ASPECTS OF CURRENT TRANSIENTS AND COMPARISON WITH WALL-JET ELECTRODES IN CONTINUOUS-FLOW [J].
BRETT, CMA ;
BRETT, AMO ;
MITOSERIU, LC .
ELECTROANALYSIS, 1995, 7 (03) :225-229
[5]   Flow injection analysis of doxycycline or chlortetracycline in pharmaceutical formulations with pulsed amperometric detection [J].
Charoenraks, T ;
Palaharn, S ;
Grudpan, K ;
Siangproh, W ;
Chailapakul, O .
TALANTA, 2004, 64 (05) :1247-1252
[6]   Fast mapping of gunshot residues by batch injection analysis with anodic stripping voltammetry of lead at the hanging mercury drop electrode [J].
De Donato, A ;
Gutz, IGR .
ELECTROANALYSIS, 2005, 17 (02) :105-112
[7]   MULTICOMPONENT BATCH-INJECTION ANALYSIS USING AN ARRAY OF ION-SELECTIVE ELECTRODES [J].
DIAMOND, D ;
LU, JM ;
CHEN, Q ;
WANG, J .
ANALYTICA CHIMICA ACTA, 1993, 281 (03) :629-635
[8]   Simple Flow Injection Amperometric System for Simultaneous Determination of Dipyrone and Paracetamol in Pharmaceutical Formulations [J].
dos Santos, Wallans T. P. ;
Gimenes, Denise T. ;
de Almeida, Edimar G. N. ;
Eiras, Sebastiao de P. ;
Albuquerque, Yaico D. T. ;
Richter, Eduardo M. .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2009, 20 (07) :1249-1255
[9]   Stripping Voltammetry of Trace Metals at Bismuth-Film Electrodes by Batch-Injection Analysis [J].
Economou, Anastasios ;
Voulgaropoulos, Anastasios .
ELECTROANALYSIS, 2010, 22 (13) :1468-1475
[10]   Internal standard in flow injection analysis with amperometric detection [J].
Gimenes, Denise Tofanello ;
Pio dos Santos, Wallans Torres ;
Abarza Munoz, Rodrigo Alejandro ;
Richter, Eduardo Mathias .
ELECTROCHEMISTRY COMMUNICATIONS, 2010, 12 (02) :216-218