Comparison of two- and three-dimensional transthoracic echocardiography for measurement of aortic annulus diameter in children

被引:14
作者
Martin, Romain [1 ]
Hascoet, Sebastien [1 ]
Dulac, Yves [1 ]
Peyre, Marianne [1 ]
Mejean, Simon [1 ]
Hadeed, Khaled [1 ]
Cazavet, Alexandre [1 ]
Leobon, Bertrand [1 ]
Acar, Philippe [1 ]
机构
[1] Toulouse Univ Hosp, Childrens Hosp, Paediat Cardiol Unit, F-31059 Toulouse 9, France
关键词
Aortic valve; Three-dimensional echocardiography; Children; Aortic annulus; Two-dimensional echocardiography; CONGENITAL HEART-DISEASE; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; VALVE IMPLANTATION; 3D ECHOCARDIOGRAPHY; COMPUTED-TOMOGRAPHY; STENOSIS; VALVULOPLASTY; ROOT; RECOMMENDATIONS; ACCURACY;
D O I
10.1016/j.acvd.2013.06.049
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Accurate evaluation of aortic root geometry is necessary in congenital aortic valve lesions in children, to guide surgical or angiographical intervention. Aim. To compare aortic annulus diameters measured by two- and three-dimensional transthoracic echocardiography (2D- and 3D-TTE), to determine the feasibility and reproducibility of 3D imaging and assess the dynamic changes during the cardiac cycle. Methods. Thirty children without heart disease were prospectively included. Two orthogonal aortic annulus diameters were measured offline using multiplanar reconstruction in diastole and in systole and were compared with the measurement of the aortic annulus diameter by 2D-TTE. Results. Mean age was 11 +/- 3.6 years. Feasibility of 3D imaging was 100%. The coefficients of intra- and interobserver variability were 3.5% and 6%, respectively. The 2D mean diameter was significantly smaller than the 3D maximum diameter in systole (1.94 vs. 2.01 mm; p=0.005).2D and 3D measurements were well correlated (p <0.0001). The maximum and minimum diameters in 3D were significantly different both in systole and in diastole (p <0.001) underlining an aortic annulus eccentricity. The mean aortic annulus diameters were not significantly different between systole and diastole, with important individual variability during the cardiac cycle. Conclusion. This study demonstrated the feasibility and reproducibility of 3D-TIE for the assessment of the aortic annulus diameter in a normal paediatric population. Because of an underestimation of the maximum diameter by 2D-TTE and the asymmetry of the aortic annulus, 3D measurements could be important before percutaneous aortic valvuloplasty or surgical replacement. (C) 2013 Published by Elsevier Masson SAS.
引用
收藏
页码:492 / 500
页数:9
相关论文
共 26 条
[1]   Live 3D echocardiography with the pediatric matrix probe [J].
Acar, Philippe ;
Abadir, Sylvia ;
Paranon, Soizic ;
Latcu, Gabriel ;
Grosjean, Juliette ;
Dulac, Yves .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2007, 24 (07) :750-755
[2]   Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation [J].
Altiok, Ertunc ;
Koos, Ralf ;
Schroeder, Joerg ;
Brehmer, Kathrin ;
Hamada, Sandra ;
Becker, Michael ;
Mahnken, Andreas H. ;
Almalla, Mohammad ;
Dohmen, Guido ;
Autschbach, Ruediger ;
Marx, Nikolaus ;
Hoffmann, Rainer .
HEART, 2011, 97 (19) :1578-1584
[3]   Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization [J].
Bacher, K ;
Bogaert, E ;
Lapere, R ;
De Wolf, D ;
Thierens, H .
CIRCULATION, 2005, 111 (01) :83-89
[4]  
Black D, 2012, J INVASIVE CARDIOL, V24, P594
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Usefulness of three-dimensional transthoracic echocardiography for the classification of congenital bicuspid aortic valve in children [J].
Blaye-Felice, Marie-Adrienne Sadron ;
Seguela, Pierre-Emmanuel ;
Arnaudis, Brice ;
Dulac, Yves ;
Lepage, Benoit ;
Acar, Philippe .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (12) :1047-1052
[7]   Usefulness of Doppler echocardiography guidance during balloon aortic valvuloplasty for the treatment of congenital aortic stenosis [J].
Bourgault, Christine ;
Rodes-Cabau, Josep ;
Cote, Jean-Marc ;
Chetaille, Philippe ;
Delisle, George ;
Perron, Jean ;
Dugas, Marc-Andre ;
Leblanc, Marie-Helene ;
Houde, Christine .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 128 (01) :30-37
[8]   Surgical Valvuloplasty Versus Balloon Aortic Dilation for Congenital Aortic Stenosis: Are Evidence-Based Outcomes Relevant? [J].
Brown, John W. ;
Rodefeld, Mark D. ;
Ruzmetov, Mark ;
Eltayeb, Osama ;
Yurdakok, Okan ;
Turrentine, Mark W. .
ANNALS OF THORACIC SURGERY, 2012, 94 (01) :146-155
[9]   Assessment of valvular surfaces in children with a congenital bicuspid aortic valve: Preliminary three-dimensional echocardiographic study [J].
Cognet, Thomas ;
Seguela, Pierre-Emmanuel ;
Thomson, Emilie ;
Bouisset, Frederic ;
Lairez, Olivier ;
Hascoet, Sebastien ;
Carrie, Didier ;
Acar, Philippe .
ARCHIVES OF CARDIOVASCULAR DISEASES, 2013, 106 (05) :295-302
[10]   Aortic root dimension changes during systole and diastole: evaluation with ECG-gated multidetector row computed tomography [J].
de Heer, Linda M. ;
Budde, Ricardo P. J. ;
Mali, Willem P. Th. M. ;
de Vos, Alexander M. ;
van Herwerden, Lex A. ;
Kluin, Jolanda .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (08) :1195-1204