Comparison of Proteins in Whole Blood and Dried Blood Spot Samples by LC/MS/MS

被引:42
作者
Chambers, Andrew G. [1 ]
Percy, Andrew J. [1 ]
Hardie, Darryl B. [1 ]
Borchers, Christoph H. [1 ,2 ]
机构
[1] Univ Victoria, Genome British Columbia Prote Ctr, Victoria, BC V8Z 7X8, Canada
[2] Univ Victoria, Dept Biochem & Microbiol, Victoria, BC V8P 5C2, Canada
关键词
Dried blood spots; Bottom-up proteomics; Proteins; LC/MS/MS; TANDEM MASS-SPECTROMETRY; MULTIPLEXED QUANTITATION; PLASMA SPOTS; BIOMARKERS; PROTEOME; TECHNOLOGY; COLLECTION; EXTRACTION; ASSAYS;
D O I
10.1007/s13361-013-0678-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Dried blood spot (DBS) sampling methods are desirable for population-wide biomarker screening programs because of their ease of collection, transportation, and storage. Immunoassays are traditionally used to quantify endogenous proteins in these samples but require a separate assay for each protein. Recently, targeted mass spectrometry (MS) has been proposed for generating highly-multiplexed assays for biomarker proteins in DBS samples. In this work, we report the first comparison of proteins in whole blood and DBS samples using an untargeted MS approach. The average number of proteins identified in undepleted whole blood and DBS samples by liquid chromatography (LC)/MS/MS was 223 and 253, respectively. Protein identification repeatability was between 77 %-92 % within replicates and the majority of these repeated proteins (70 %) were observed in both sample formats. Proteins exclusively identified in the liquid or dried fluid spot format were unbiased based on their molecular weight, isoelectric point, aliphatic index, and grand average hydrophobicity. In addition, we extended this comparison to include proteins in matching plasma and serum samples with their dried fluid spot equivalents, dried plasma spot (DPS), and dried serum spot (DSS). This work begins to define the accessibility of endogenous proteins in dried fluid spot samples for analysis by MS and is useful in evaluating the scope of this new approach.
引用
收藏
页码:1338 / 1345
页数:8
相关论文
共 31 条
[1]   Use of Dried Plasma Spots in the Determination of Pharmacokinetics in Clinical Studies: Validation of a Quantitative Bioanalytical Method [J].
Barfield, Matthew ;
Wheller, Robert .
ANALYTICAL CHEMISTRY, 2011, 83 (01) :118-124
[2]   Newborn Screening for Sickle Cell Disease Using Tandem Mass Spectrometry [J].
Boemer, Francois ;
Ketelslegers, Olivier ;
Minon, Jean-Marc ;
Bours, Vincent ;
Schoos, Roland .
CLINICAL CHEMISTRY, 2008, 54 (12) :2036-2041
[3]   Dried blood spot sampling: practical considerations and recommendation for use with preclinical studies [J].
Burnett, Josephine E. C. .
BIOANALYSIS, 2011, 3 (10) :1099-1107
[4]   Use of tandem mass spectrometry for multianalyte screening of dried blood specimens from newborns [J].
Chace, DH ;
Kalas, TA ;
Naylor, EW .
CLINICAL CHEMISTRY, 2003, 49 (11) :1797-1817
[5]   Multiplexed Quantitation of Endogenous Proteins in Dried Blood Spots by Multiple Reaction Monitoring - Mass Spectrometry [J].
Chambers, Andrew G. ;
Percy, Andrew J. ;
Yang, Juncong ;
Camenzind, Alexander G. ;
Borchers, Christoph H. .
MOLECULAR & CELLULAR PROTEOMICS, 2013, 12 (03) :781-791
[6]   Quantification of hemoglobin A2 by tandem mass spectrometry [J].
Daniel, Yvonne A. ;
Turner, Charles ;
Haynes, Roberta M. ;
Hunt, Beverley J. ;
Dalton, Neil .
CLINICAL CHEMISTRY, 2007, 53 (08) :1448-1454
[7]   Tryptic Peptide Analysis of Ceruloplasmin in Dried Blood Spots Using Liquid Chromatography-Tandem Mass Spectrometry: Application to Newborn Screening [J].
Dewilde, Amy ;
Sadilkova, Katerina ;
Sadilek, Martin ;
Vasta, Valeria ;
Hahn, Si Houn .
CLINICAL CHEMISTRY, 2008, 54 (12) :1961-1968
[8]   MRM-based multiplexed quantitation of 67 putative cardiovascular disease biomarkers in human plasma [J].
Domanski, Dominik ;
Percy, Andrew J. ;
Yang, Juncong ;
Chambers, Andrew G. ;
Hill, John S. ;
Freue, Gabriela V. Cohen ;
Borchers, Christoph H. .
PROTEOMICS, 2012, 12 (08) :1222-1243
[9]   Dried Blood Spot Methods in Therapeutic Drug Monitoring: Methods, Assays, and Pitfalls [J].
Edelbroek, Peter M. ;
van der Heijden, Jacques ;
Stolk, Leo M. L. .
THERAPEUTIC DRUG MONITORING, 2009, 31 (03) :327-336
[10]   HbA1c measurements from dried blood spots: validation and patient satisfaction [J].
Fokkema, M. Rebecca ;
Bakker, Andries J. ;
de Boer, Fokje ;
Kooistra, Jeltsje ;
de Vries, Sifra ;
Wolthuis, Albert .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2009, 47 (10) :1259-1264