Toward the Guidance of Transbronchial Biopsy Identifying Pulmonary Nodules With Optical Coherence Tomography

被引:38
作者
Hariri, Lida P. [1 ,4 ,6 ]
Mino-Kenudson, Mari [1 ,6 ]
Applegate, Matthew B. [2 ,3 ,4 ]
Mark, Eugene J. [1 ,6 ]
Tearney, Guillermo J. [1 ,4 ,6 ,7 ]
Lanuti, Michael [5 ,6 ]
Channick, Colleen L. [2 ,3 ,6 ]
Chee, Alex [2 ,3 ,4 ]
Suter, Melissa J. [2 ,3 ,4 ,6 ]
机构
[1] Massachusetts Gen Hosp, Dept Pathol, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Dept Pulm, Boston, MA 02114 USA
[3] Massachusetts Gen Hosp, Crit Care Unit, Boston, MA 02114 USA
[4] Massachusetts Gen Hosp, Wellman Ctr Photomed, Boston, MA 02114 USA
[5] Massachusetts Gen Hosp, Dept Thorac Surg, Boston, MA 02114 USA
[6] Harvard Univ, Sch Med, Boston, MA USA
[7] Harvard Mit Div Hlth Sci & Technol, Boston, MA USA
关键词
GUIDELINES 2ND EDITION; LUNG-CANCER; IN-VIVO; BARRETTS-ESOPHAGUS; BRONCHIAL LESIONS; NEEDLE; DIAGNOSIS; BRONCHOSCOPY; MICROSCOPY; METAANALYSIS;
D O I
10.1378/chest.13-0534
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Solitary pulmonary nodules (SPNs) frequently require transbronchial needle aspiration (TBNA) or biopsy to determine malignant potential, but have variable diagnostic yields. Confirming needle placement within SPNs during TBNA could significantly increase diagnostic yield. Optical coherence tomography (OCT) provides nondestructive, high-resolution, microstructural imaging with potential to distinguish SPN from parenchyma. We have developed needle-based OCT probes compatible with TBNA. Before OCT can play any significant role in guiding clinical TBNA, OCT interpretation criteria for differentiating SPN from lung parenchyma must be developed and validated. Methods: OCT of SPN and parenchyma was performed on 111 ex vivo resection specimens. OCT criteria for parenchyma and SPN were developed and validated in a blinded assessment. Six blinded readers (two pulmonologists, two pathologists, and two OCT experts) were trained on imaging criteria in a 15-min training session prior to interpreting the validation data set. Results: OCT of lung parenchyma displayed evenly spaced signal-void alveolar spaces, signal-intense backreflections at tissue-air interfaces, or both. SPNs lacked both of these imaging features. Independent validation of OCT criteria by the six blinded readers demonstrated sensitivity and specificity of 95.4% and 98.2%, respectively. Conclusions: We have developed and validated OCT criteria for lung parenchyma and SPN with sensitivity and specificity. 95% in this ex vivo study. We anticipate that OCT could be a useful complementary imaging modality to confirm needle placement during TBNA to potentially increase diagnostic yield.
引用
收藏
页码:1261 / 1268
页数:8
相关论文
共 47 条
[1]   Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening [J].
Aberle, Denise R. ;
Adams, Amanda M. ;
Berg, Christine D. ;
Black, William C. ;
Clapp, Jonathan D. ;
Fagerstrom, Richard M. ;
Gareen, Ilana F. ;
Gatsonis, Constantine ;
Marcus, Pamela M. ;
Sicks, JoRean D. .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (05) :395-409
[2]   Cellular resolution ex vivo imaging of gastrointestinal tissues with optical coherence microscopy [J].
Aguirre, Aaron D. ;
Chen, Yu ;
Bryan, Bradley ;
Mashimo, Hiroshi ;
Huang, Qin ;
Connolly, James L. ;
Fujimoto, James G. .
JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (01)
[3]   Diagnostic yield of fiberoptic bronchoscopy in evaluating solitary pulmonary nodules [J].
Baaklini, WA ;
Reinoso, MA ;
Gorin, AB ;
Sharafkanch, A ;
Manian, P .
CHEST, 2000, 117 (04) :1049-1054
[4]   Intracoronary Optical Coherence Tomography: A Comprehensive Review Clinical and Research Applications [J].
Bezerra, Hiram G. ;
Costa, Marco A. ;
Guagliumi, Giulio ;
Rollins, Andrew M. ;
Simon, Daniel I. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (11) :1035-1046
[5]   High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography [J].
Bouma, BE ;
Tearney, GJ ;
Compton, CC ;
Nishioka, NS .
GASTROINTESTINAL ENDOSCOPY, 2000, 51 (04) :467-474
[6]   Optical coherence tomography for optical biopsy - Properties and demonstration of vascular pathology [J].
Brezinski, ME ;
Tearney, GJ ;
Bouma, BE ;
Izatt, JA ;
Hee, MR ;
Swanson, EA ;
Southern, JF ;
Fujimoto, JG .
CIRCULATION, 1996, 93 (06) :1206-1213
[7]  
Cense B, 2006, Bull Soc Belge Ophtalmol, P123
[8]   Ultrahigh resolution optical coherence tomography of Barrett's esophagus: preliminary descriptive clinical study correlating images with histology [J].
Chen, Y. ;
Aguirre, A. D. ;
Hsiung, P.-L. ;
Desai, S. ;
Herz, P. R. ;
Pedrosa, M. ;
Huang, Q. ;
Figueiredo, M. ;
Huang, S.-W. ;
Koski, A. ;
Schmitt, J. M. ;
Fujimoto, J. G. ;
Mashimo, H. .
ENDOSCOPY, 2007, 39 (07) :599-605
[9]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[10]   New Insights Into the Coronary Artery Bifurcation Hypothesis-Generating Concepts Utilizing 3-Dimensional Optical Frequency Domain Imaging [J].
Farooq, Vasim ;
Serruys, Patrick W. ;
Heo, Jung Ho ;
Gogas, Bill D. ;
Okamura, Takayuki ;
Gomez-Lara, Josep ;
Brugaletta, Salvatore ;
Garcia-Garcia, Hector M. ;
van Geuns, Robert Jan .
JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (08) :921-931