A Physiological Information Extraction Method Based on Wearable PPG Sensors with Motion Artifact Removal

被引:11
作者
Lin, Wei-Jheng [1 ]
Ma, Hsi-Pin [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Elect Engn, Hsinchu, Taiwan
来源
2016 IEEE INTERNATIONAL CONFERENCE ON COMMUNICATIONS (ICC) | 2016年
关键词
PPG; motion artifact; discrete wavelet transform; support vector machine; Kalman filter; PULSE OXIMETRY; PHOTOPLETHYSMOGRAPHY; REDUCTION;
D O I
10.1109/ICC.2016.7511485
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a method to extract physiological information from Photoplethysmography (PPG) signal with motion artifact detection and removal is proposed. First, PPG data recorded from wearable sensors are pre-processed by discrete wavelet transform to remove unwanted noise and extract AC/DC component. Then, the characteristic points such as peaks and troughs are identified for feature extraction and physiological information extraction. To detect the motion artifact periods, we use support vector machine (SVM) for classification. The detection performance was verified by PPG signals from 11 different healthy subjects. The proposed method operates in 7 seconds with accuracy of 94.4%, sensitivity of 90.35%, and specificity of 99.36%. The motion artifact removal is accomplished by Kalman filter to track the SpO(2) and heart rate (HR) extracted from motion artifact-corrupted periods. The parameters of Kalman filter are determined by the detection results. In the case of waving hand left-right, the average mean absolute bias of artifact-corrupted SpO(2) and HR are 1.34% and 7.29 bpm, respectively. After applying the algorithm, the bias becomes 0.8% and 4.29 bpm. In the case of waving hand up and down, the errors of SpO(2) and HR reduce from 1.31% to 0.82% and 13.97 bpm to 6.87 bpm.
引用
收藏
页数:6
相关论文
共 14 条
[1]   MAXIMAL PERFUSION OF SKELETAL-MUSCLE IN MAN [J].
ANDERSEN, P ;
SALTIN, B .
JOURNAL OF PHYSIOLOGY-LONDON, 1985, 366 (SEP) :233-249
[2]  
Asada HH, 2004, P ANN INT IEEE EMBS, V26, P2157
[3]   How does the plethysmogram derived from the pulse oximeter relate to arterial blood pressure in coronary artery bypass graft patients? [J].
Awad, AA ;
Ghobashy, MAM ;
Stout, RG ;
Silverman, DG ;
Shelley, KH .
ANESTHESIA AND ANALGESIA, 2001, 93 (06) :1466-1471
[4]   COMPUTERIZED PHOTOPLETHYSMOGRAPHY OF THE FINGER [J].
BLANC, VF ;
HAIG, M ;
TROLI, M ;
SAUVE, B .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1993, 40 (03) :271-278
[5]  
Chong J. W., 2014, ANN BIOMED ENG, P1
[6]   DE-NOISING BY SOFT-THRESHOLDING [J].
DONOHO, DL .
IEEE TRANSACTIONS ON INFORMATION THEORY, 1995, 41 (03) :613-627
[7]   Motion artifact reduction in photoplethysmography using independent component analysis [J].
Kim, BS ;
Yoo, SK .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (03) :566-568
[8]   Two-Stage Approach for Detection and Reduction of Motion Artifacts in Photoplethysmographic Data [J].
Krishnan, Rajet ;
Natarajan, Balasubramaniam ;
Warren, Steve .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (08) :1867-1876
[9]   The pNNx files: re-examining a widely used heart rate variability measure [J].
Mietus, JE ;
Peng, CK ;
Henry, I ;
Goldsmith, RL ;
Goldberger, AL .
HEART, 2002, 88 (04) :378-380
[10]   PULSE OXIMETRY - TECHNICAL ASPECTS OF MACHINE-DESIGN [J].
POLOGE, JA .
INTERNATIONAL ANESTHESIOLOGY CLINICS, 1987, 25 (03) :137-153