Kinematic calibration of a five-bar planar parallel robot using all working modes

被引:72
作者
Joubair, Ahmed [1 ]
Slamani, Mohamed [1 ]
Bonev, Ilian A. [1 ]
机构
[1] Ecole Technol Super, Montreal, PQ, Canada
基金
加拿大创新基金会;
关键词
Robot calibration; Parallel robot; Five-bar mechanism; Accuracy;
D O I
10.1016/j.rcim.2012.10.002
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We present a simple low-cost calibration procedure that improves the planar positioning accuracy of a double-arm SCARA robot to levels difficult or impossible to achieve using an equivalent serial robot. Measurements are based on the use of five custom designed magnetic tooling balls fixed to the periphery of a detachable working plate. Three of these tooling balls define the world reference frame of the robot, and the positions of the centers of all balls are measured on a CMM. A special magnetic cup end-effector is used. Measurements are taken by manually positioning the end-effector over each of the tooling balls, with each of the maximum of four possible robot configurations. Each of these measurements is repeatable to within +/- 0.015 mm. The robot calibration model includes all 12 kinematic parameters, and the calibration method used is based on the linearization of the direct kinematics model in each calibration configuration. The optimal number and location of the tooling balls is obtained by studying the observability index. Finally, an experimental validation at 14 additional tooling balls shows that the maximum position error with respect to the world frame is reduced to 0.080 mm within the entire robot's workspace of 600 mm x 600 mm. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:15 / 25
页数:11
相关论文
共 30 条
[1]   AUTONOMOUS CALIBRATION OF SINGLE-LOOP CLOSED KINEMATIC CHAINS FORMED BY MANIPULATORS WITH PASSIVE END-POINT CONSTRAINTS [J].
BENNETT, DJ ;
HOLLERBACH, JM .
IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION, 1991, 7 (05) :597-606
[2]   EXPERIMENTAL-STUDY OF OBSERVABILITY OF PARAMETER ERRORS IN ROBOT CALIBRATION [J].
BORM, JH ;
MENQ, CH .
PROCEEDINGS - 1989 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOL 1-3, 1989, :587-592
[3]   DETERMINATION OF OPTIMAL MEASUREMENT CONFIGURATIONS FOR ROBOT CALIBRATION BASED ON OBSERVABILITY MEASURE [J].
BORM, JH ;
MENQ, CH .
INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 1991, 10 (01) :51-63
[4]   Are parallel robots more accurate than serial robots? [J].
Briot, Sebastien ;
Bonev, Ilian A. .
TRANSACTIONS OF THE CANADIAN SOCIETY FOR MECHANICAL ENGINEERING, 2007, 31 (04) :445-455
[5]  
Campos L., 2010, P ASME 2010 INT DES
[6]   Choosing measurement poses for robot calibration with the local convergence method and tabu search [J].
Daney, D ;
Papegay, Y ;
Madeline, B .
INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2005, 24 (06) :501-518
[7]  
Ding Q, 2005, P INT C MECH AUT NIA
[8]   SIGNIFICANCE OF OBSERVATION STRATEGY ON THE DESIGN OF ROBOT CALIBRATION EXPERIMENTS [J].
DRIELS, MR ;
PATHRE, US .
JOURNAL OF ROBOTIC SYSTEMS, 1990, 7 (02) :197-223
[9]  
Durango S, 2010, P ICINCO 2010 7 INT
[10]   A SINGLE-POINT CALIBRATION TECHNIQUE FOR A 6-DEGREE-OF-FREEDOM ARTICULATED ARM [J].
EDWARDS, CA ;
GALLOWAY, RL .
INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 1994, 13 (03) :189-198