Comparison of Three Techniques in Measuring Progressive Addition Lenses

被引:24
作者
Huang, Ching-Yao [1 ]
Raasch, Thomas W. [2 ]
Yi, Allen Y. [3 ]
Sheedy, James E. [4 ]
Andre, Brett [4 ]
Bullimore, Mark A. [5 ]
机构
[1] Shu Zen Coll Med & Management, Dept Optometry, Taipei, Taiwan
[2] Ohio State Univ, Coll Optometry, Columbus, OH 43210 USA
[3] Ohio State Univ, Coll Engn, Columbus, OH 43210 USA
[4] Univ Pacific, Coll Optometry, Forest Grove, OR USA
[5] Univ Houston, Coll Optometry, Houston, TX USA
关键词
progressive addition lenses; Hartmann-Shack aberrometry; moire interferometry; surface profilometry; coordinate measuring machine; wavefront aberrations; POWER LENSES; SPECTACLE LENSES; VIEWING CONDITIONS; HARTMANN TEST; ABERRATIONS; DESIGN; OPTICS;
D O I
10.1097/OPX.0b013e31826ca26b
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To measure progressive addition lenses (PALs) by three techniques and to compare the differences across techniques. Methods. Five contemporary PALs (Varilux Comfort Enhanced, Varilux Physio Enhanced, Hoya Lifestyle, Shamir Autograph, and Zeiss individual) with plano distance power and a +2.00 diopters (D) add were evaluated under the condition of lateral displacement of the lens (no rotation and no tilt) using three methods. A Hartmann-Shack wavefront sensor (HSWFS) on a custom-built optical bench was used to capture and measure wavefront aberrations. A Rotlex Class Plus lens analyzer operating as a moire interferometer was used to measure spherical and cylindrical powers. A coordinate measuring machine (CMM) was used to measure front and back surfaces of PALs and converted to desired optical properties. The data were analyzed with MATLAB programs. Contour plots of spherical equivalent power, cylindrical power, and higher-order aberrations (HOAs) in all PALs were generated to compare their differences. Results. The differences in spherical equivalent and cylinder at distance, near, and progressive corridor areas among the HSWFS, Rotlex, and CMM methods were close to zero in all five PALs. The maximum differences are approximately 0.50 D and located below the near power zone and the edge areas of the lens when comparing the HSWFS and CMM with the Rotlex. HOAs measured both by the HSWFS and CMM were highest in the corridor area and the area surrounding the near zone in all PALs. The HOAs measured by the CMM were lower than those from the HSWFS by 0.02 to 0.04 mu m. Conclusions. The three measurement methods are comparable for measuring spherical and cylindrical power across PALs. The non-optical method, CMM, can be used to evaluate the optical properties of a PAL by measuring front and back surface height measurements, although its estimates of HOAs are lower than those from the HSWFS. (Optom Vis Sci 2012;89:1564-1573)
引用
收藏
页码:1564 / 1573
页数:10
相关论文
共 43 条
[1]  
Atchison DA., 1987, Clin Exp Optom, V70, P149, DOI DOI 10.1111/J.1444-0938.1987.TB04235.X
[2]  
Bavli R, 2010, MAFO OPHTHAL LABS IN, V7, P30
[3]  
Boroyan H J, 1995, J Am Optom Assoc, V66, P296
[4]   TRAPS IN DISPLAYING OPTICAL PERFORMANCES OF A PROGRESSIVE-ADDITION LENS [J].
BOURDONCLE, B ;
CHAUVEAU, JP ;
MERCIER, JL .
APPLIED OPTICS, 1992, 31 (19) :3586-3593
[5]   HARTMANN TEST MODIFICATION FOR MEASURING OPHTHALMIC PROGRESSIVE LENSES [J].
CASTELLINI, C ;
FRANCINI, F ;
TIRIBILLI, B .
APPLIED OPTICS, 1994, 33 (19) :4120-4124
[6]  
Cho M H, 1991, J Am Optom Assoc, V62, P449
[7]  
DIEPES H, 1988, AM J OPTOM PHYS OPT, V65, P571
[8]   Technical note: Apparatus for comparison of progressive addition spectacle lenses [J].
Fowler, C. W. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2006, 26 (05) :502-506
[9]   A COMPARISON OF 3 METHODS FOR THE MEASUREMENT OF PROGRESSIVE ADDITION LENSES [J].
FOWLER, CW ;
SULLIVAN, CM .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1989, 9 (01) :81-85
[10]  
FOWLER CW, 1990, OPHTHAL PHYSL OPT, V10, P86, DOI 10.1111/j.1475-1313.1990.tb01112.x