Stereotactic CT-Guided Percutaneous Microwave Ablation of Liver Tumors With the Use of High-Frequency Jet Ventilation: An Accuracy and Procedural Safety Study

被引:71
|
作者
Engstrand, Jennie [1 ]
Toporek, Grzegorz [2 ]
Harbut, Piotr [1 ]
Jonas, Eduard [1 ]
Nilsson, Henrik [1 ]
Freedman, Jacob [1 ]
机构
[1] Danderyd Hosp AB, Danderyd Hosp, Dept Clin Sci, Karolinska Inst, SE-18288 Stockholm, Sweden
[2] Univ Bern, ARTORG Ctr Biomed Engn Res, Bern, Switzerland
关键词
accuracy; interventional radiology; liver; microwave ablation; stereotaxy; RADIOFREQUENCY ABLATION; HEPATIC-TUMORS; HEPATOCELLULAR-CARCINOMA; NAVIGATION SYSTEM; THERMAL ABLATION; GUIDANCE; PHANTOM; BIOPSY; THERMOABLATION; FEASIBILITY;
D O I
10.2214/AJR.15.15803
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of the present study is to evaluate the accuracy and safety of antenna placement performed with the use of a CT-guided stereotactic navigation system for percutaneous ablation of liver tumors and to assess the safety of high-frequency jet ventilation for target motion control. MATERIALS AND METHODS. Twenty consecutive patients with malignant liver lesions for which surgical resection was contraindicated or that were not readily visible on ultrasound or not accessible by ultrasound guidance were included in the study. Patients were treated with percutaneous microwave ablation performed using a CT-guided stereotactic navigation system. High-frequency jet ventilation was used to reduce liver motion during all interventions. The accuracy of antenna placement, the number of needle readjustments required, overall safety, and the radiation doses were assessed. RESULTS. Microwave ablation was completed for 20 patients (28 lesions). Performance data could be evaluated for 17 patients with 25 lesions (mean [+/- SD] lesion diameter, 14.9 +/- 5.9 mm; mean lesion location depth, 87.5 +/- 27.3 mm). The antennae were placed with a mean lateral error of 4.0 +/- 2.5 mm, a depth error of 3.4 +/- 3.2 mm, and a total error of 5.8 +/- 3.2 mm in relation to the intended target. The median number of antenna readjustments required was zero (range, 0-1 adjustment). No major complications were related to either the procedure or the use of high-frequency jet ventilation. The mean total patient radiation dose was 957.5 +/- 556.5 mGy x cm, but medical personnel were not exposed to irradiation. CONCLUSION. Percutaneous microwave ablation performed with CT-guided stereotactic navigation provides sufficient accuracy and requires almost no repositioning of the -needle. Therefore, it is technically feasible and applicable for safe treatments.
引用
收藏
页码:193 / 200
页数:8
相关论文
共 38 条
  • [31] Unresectable Colorectal Liver Metastases: Percutaneous Ablation Using CT-Guided High-Dose-Rate Brachytherapy (CT-HDBRT)
    Collettini, F.
    Lutter, A.
    Schnapauff, D.
    Hildebrandt, B.
    Puhl, G.
    Denecke, T.
    Wust, P.
    Gebauer, B.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (06): : 606 - 612
  • [32] High-frequency jet ventilation for minimizing breathing-related liver motion during percutaneous radiofrequency ablation of multiple hepatic tumours
    Biro, P.
    Spahn, D. R.
    Pfammatter, T.
    BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (05) : 650 - 653
  • [33] Major complications of high-energy microwave ablation for percutaneous CT-guided treatment of lung malignancies: Single-centre experience after 4 years
    Splatt, Alexander M.
    Steinke, Karin
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2015, 59 (05) : 609 - 616
  • [34] The use of Esketamine in CT-guided percutaneous liver tumor ablation reduces the consumption of remifentanil: a randomized, controlled, double-blind trial
    Su, Yanbing
    Zhang, Jianxing
    Wang, Huanwei
    Gu, Yangkui
    Ouyang, Handong
    Huang, Wan
    ANNALS OF TRANSLATIONAL MEDICINE, 2022, 10 (12)
  • [35] The safety and feasibility of three-dimensional visualization planning system for CT-guided microwave ablation of stage I NSCLC (diameter ≤2.5 cm): A pilot study
    Hu, Yanting
    Xue, Guoliang
    Liang, Xinyu
    Wu, Jing
    Zhang, Peng
    Wang, Nan
    Li, Zhichao
    Cao, Pikun
    Wang, Gang
    Cai, Hongchao
    Wei, Zhigang
    Ye, Xin
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2023, 19 (01) : 64 - 70
  • [36] Safety and efficacy of CT-guided percutaneous microwave ablation for stage I non-small cell lung cancer in patients with comorbid idiopathic pulmonary fibrosis
    Peng, JinZhao
    Bie, ZhiXin
    Li, YuanMing
    Guo, RunQi
    Li, XiaoGuang
    EUROPEAN RADIOLOGY, 2024, 34 (07) : 4708 - 4715
  • [37] CT-guided 125I brachytherapy for hepatocellular carcinoma in high-risk locations after transarterial chemoembolization combined with microwave ablation: a propensity score-matched study
    Chen, Zixiong
    Fu, Xiaobo
    Qiu, Zhenkang
    Mu, Maoyuan
    Jiang, Weiwei
    Wang, Guisong
    Zhong, Zhihui
    Qi, Han
    Gao, Fei
    RADIOLOGY AND ONCOLOGY, 2023, 57 (01) : 127 - 139
  • [38] Ultrasound-guided percutaneous high-frequency irreversible electroporation in porcine livers using four electrode needles: A feasibility and safety study
    Li, Chang-Tian
    Zhao, Guo-Dong
    Zou, Wen-Bo
    Zhang, Zhen-Hua
    Zhao, Yi
    Liu, Rong
    CANCER MEDICINE, 2024, 13 (05):