Detection of extremely low concentration waterborne pathogen using a multiplexing self-referencing SERS microfluidic biosensor

被引:71
作者
Wang, Chao [1 ]
Madiyar, Foram [2 ]
Yu, Chenxu [1 ]
Li, Jun [2 ]
机构
[1] Iowa State Univ, Agr & Biosyst Engn Dept, Ames, IA 50011 USA
[2] Kansas State Univ, Chem Dept, Manhattan, KS 66506 USA
关键词
LABEL-FREE SERS; RAMAN-SPECTROSCOPY; BACTERIA; DIELECTROPHORESIS; IDENTIFICATION; COLI;
D O I
10.1186/s13036-017-0051-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: It is challenging to achieve ultrasensitive and selective detection of waterborne pathogens at extremely low levels (i.e., single cell/mL) using conventional methods. Even with molecular methods such as ELISA or PCR, multi-enrichment steps are needed which are labor and cost intensive. In this study, we incorporated nano-dielectrophoretic microfluidic device with Surface enhanced Raman scattering (SERS) technique to build a novel portable biosensor for easy detection and characterization of Escherichia coli O157:H7 at high sensitivity level (single cell/mL). Results: A multiplexing dual recognition SERS scheme was developed to achieve one-step target detection without the need to separate target-bound probes from unbound ones. With three different SERS-tagged molecular probes targeting different epitopes of the same pathogen being deployed simultaneously, detection of pathogen targets was achieved at single cell level with sub-species specificity that has not been reported before in single-step pathogen detection. Conclusion: The self-referencing protocol implements with a Nano-dielectrophoretic microfluidic device potentially can become an easy-to-use, field-deployable spectroscopic sensor for onsite detection of pathogenic microorganisms.
引用
收藏
页数:11
相关论文
共 37 条
[1]   Biosensors for Whole-Cell Bacterial Detection [J].
Ahmed, Asif ;
Rushworth, Jo V. ;
Hirst, Natalie A. ;
Millner, Paul A. .
CLINICAL MICROBIOLOGY REVIEWS, 2014, 27 (03) :631-646
[2]   Chemically immobilized T4-bacteriophage for specific Escherichia coli detection using surface plasmon resonance [J].
Arya, Sunil K. ;
Singh, Amit ;
Naidoo, Ravendra ;
Wu, Peng ;
McDermott, Mark T. ;
Evoy, S. .
ANALYST, 2011, 136 (03) :486-492
[3]   Rapid (<5 min) Identification of Pathogen in Human Blood by Electrokinetic Concentration and Surface-Enhanced Raman Spectroscopy [J].
Cheng, I-Fang ;
Chang, Hsien-Chang ;
Chen, Tzu-Ying ;
Hu, Chenming ;
Yang, Fu-Liang .
SCIENTIFIC REPORTS, 2013, 3
[4]   A dielectrophoretic chip with a roughened metal surface for on-chip surface-enhanced Raman scattering analysis of bacteria [J].
Cheng, I-Fang ;
Lin, Chi-Chang ;
Lin, Dong-Yi ;
Chang, Hsien- .
BIOMICROFLUIDICS, 2010, 4 (03)
[5]   Rapid and Sensitive in Situ SERS Detection Using Dielectrophoresis [J].
Cherukulappurath, Sudhir ;
Lee, Si Hoon ;
Campos, Antonio ;
Haynes, Christy L. ;
Oh, Sang-Hyun .
CHEMISTRY OF MATERIALS, 2014, 26 (07) :2445-2452
[6]   The development of surface-enhanced Raman scattering as a detection modality for portable in vitro diagnostics: progress and challenges [J].
Driscoll, Ashley J. ;
Harpster, Mark H. ;
Johnson, Patrick A. .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2013, 15 (47) :20415-20433
[7]   Recent developments and future directions in SERS for bioanalysis [J].
Harper, Mhairi M. ;
McKeating, Kristy S. ;
Faulds, Karen .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2013, 15 (15) :5312-5328
[8]   Discrimination of bacteria using surface-enhanced Raman spectroscopy [J].
Jarvis, RM ;
Goodacre, R .
ANALYTICAL CHEMISTRY, 2004, 76 (01) :40-47
[9]  
JOHNSON JL, 1995, J FOOD PROTECT, V58, P597, DOI 10.4315/0362-028X-58.6.597
[10]   On-chip separation of Lactobacillus bacteria from yeasts using dielectrophoresis [J].
Khoshmanesh, Khashayar ;
Baratchi, Sara ;
Tovar-Lopez, Francisco J. ;
Nahavandi, Saeid ;
Wlodkowic, Donald ;
Mitchell, Arnan ;
Kalantar-zadeh, Kourosh .
MICROFLUIDICS AND NANOFLUIDICS, 2012, 12 (1-4) :597-606