Highly Cross-Linked Polyethylene in Total Hip Arthroplasty for Osteonecrosis of the Femoral Head: A Minimum 5-Year Follow-Up Study

被引:16
作者
Min, Byung-Woo [1 ]
Lee, Kyung-Jae [1 ]
Song, Kwang-Soon [1 ]
Bae, Ki-Cheor [1 ]
Cho, Chul-Hyun [1 ]
机构
[1] Keimyung Univ, Dept Orthoped Surg, Sch Med, Taegu 700712, South Korea
关键词
osteonecrosis of the femoral head; total hip arthroplasty; highly cross-linked polyethylene; CLINICAL-PERFORMANCE; PATIENTS YOUNGER; RADIOGRAPHIC EVALUATION; PENETRATION RATES; ACETABULAR LINER; WEAR; COMPONENTS; METAL; OSTEOLYSIS; THA;
D O I
10.1016/j.arth.2012.07.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We evaluated 162 hips with osteonecrosis of the femoral head that had undergone THA using highly cross-linked polyethylene liner after a minimum follow-up of 5 years. Neither femoral nor acetabular components displayed radiographic evidence of mechanical loosening or osteolysis, and no components had been revised at the latest follow-up. The mean rate of linear liner wear was 0.038 mm/year. Univariate regression analysis did not demonstrate that age, gender, weight, activity level or cup inclination had any influence on penetration. While the long term effects of altered mechanical properties of highly cross-linked PE remain unknown, the clinical and radiographic results at a minimum of 5 years are promising for this high-risk population. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:526 / 530
页数:5
相关论文
共 45 条
[1]   Effectiveness of total hip arthroplasty in the management of hip osteonecrosis [J].
Babis, GC ;
Soucacos, PN .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2004, 35 (03) :359-+
[2]   Cementless total hip arthroplasty with alumina bearings in patients younger than fifty with femoral head osteonecrosis [J].
Baek, Seung-Hoon ;
Kim, Shin-Yoon .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (06) :1314-1320
[3]  
Baker DA, 1999, J BIOMED MATER RES, V46, P573, DOI 10.1002/(SICI)1097-4636(19990915)46:4<573::AID-JBM16>3.0.CO
[4]  
2-A
[5]  
Brinker M R, 1994, J Arthroplasty, V9, P457, DOI 10.1016/0883-5403(94)90091-4
[6]   Metal-on-metal hip arthroplasty does equally well in osteonecrosis and osteoarthritis [J].
Dastane, Manish R. ;
Long, William T. ;
Wan, Zhinian ;
Chao, Lisa ;
Dorr, Lawrence D. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (05) :1148-1153
[7]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[8]  
Devane PA, 1999, CLIN ORTHOP RELAT R, P59
[9]   Highly cross-linked polyethylene in cemented THA -: Randomized study of 61 hips [J].
Digas, G ;
Kärrholm, J ;
Thanner, J ;
Malchau, H ;
Herberts, P .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (417) :126-138
[10]  
Doorn PF, 1998, J BIOMED MATER RES, V42, P103, DOI 10.1002/(SICI)1097-4636(199810)42:1<103::AID-JBM13>3.0.CO