The use of Raman spectroscopy in the analysis of UHMWPE uni-condylar bearing systems after run on a force and displacement control knee simulators

被引:20
作者
Affatato, Saverio [1 ]
Modena, Enrico [2 ]
Carmignato, Simone [3 ]
Taddei, Paola [2 ]
机构
[1] Ist Ortoped Rizzoli, Lab Tecnol Med, I-40136 Bologna, Italy
[2] Univ Bologna, Dipartimento Biochim G Moruzzi, Sez Chim & Propedeut Biochim, Bologna, Italy
[3] Univ Padua, DTG, Padua, Italy
关键词
UKP; DC simulator; FC simulator; Knee retrievals; Raman spectroscopy; Coordinate measuring machine; CROSS-LINKED POLYETHYLENE; ACETABULAR CUPS; UNICOMPARTMENTAL KNEE; IN-VITRO; MICROPROBE SPECTROSCOPY; MOLECULAR-ORIENTATION; WEAR; PROSTHESES; COMPONENTS; FIBERS;
D O I
10.1016/j.wear.2012.10.002
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The complications associated with prosthetic failure and revision surgery still constitute the main clinical problem. The objective of wear evaluation is to determine the wear rate and its dependence on the test conditions. To obtain realistic results, a wear test can be performed to reproduce in vivo working conditions and compare the wear characteristics of various total knee prostheses designs. Two knee wear simulators with different input control mechanisms, displacement and force controlled, were used to assess the wear behavior of ultra-high molecular weight polyethylene uni-condylar knee prostheses. The differences in wear behavior were assessed using a state-of-art coordinate measuring machine; Raman spectroscopy was used to evaluate the possible crystallinity changes on the uni-condylar menisci induced by mechanical stress. These results were compared with available uni-condylar retrievals. Scratches were visible along the anterior-posterior direction emphasizing that the motion was constant during the movements under the displacement control simulation. On the contrary, different kinematics schemes were observed under the force controlled simulation. The structural Raman markers showed a good correlation with the coordinate measuring machine data, and in particular with the depth of the concavity formed upon in vitro testing or in vivo service. With regards to the in vitro tested components, the specimens tested under force controlled simulator, which underwent a higher volumetric loss, showed a higher increase of the amorphous content. At a molecular level, the wear mechanism did not appear significantly different for the three sets of specimens, with the exception of the amorphous content which, upon wear, increased in the in vitro tested components, while decreased in the retrievals. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:781 / 790
页数:10
相关论文
共 35 条
[1]   Unicompartmental knee prostheses:: in vitro wear assessment of the menisci tibial insert after two different fixation methods [J].
Affatato, S. ;
Spinelli, M. ;
Zavalloni, M. ;
Carmignato, S. ;
Lopomo, N. ;
Marcacci, M. ;
Viceconti, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (19) :5357-5369
[2]   Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions [J].
Affatato, S ;
Bersaglia, G ;
Rocchi, M ;
Taddei, P ;
Fagnano, C ;
Toni, A .
BIOMATERIALS, 2005, 26 (16) :3259-3267
[3]   Fluid absorption study in ultra-high molecular weight polyethylene( UHMWPE) sterilized and unsterilized acetabular cups [J].
Affatato, S ;
Vandelli, C ;
Bordini, B ;
Toni, A .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H1) :107-111
[4]   Wear and toughness of crosslinked polyethylene for total knee replacements: A study using a simulator and small-punch testing [J].
Akagi, Masao ;
Asano, Taiyo ;
Clarke, Ian C. ;
Niiyama, Norio ;
Kyomoto, Masayuki ;
Nakamura, Takashi ;
Hamanishi, Chiaki .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (10) :2021-2027
[5]   The unicompartmental knee - Design and technical considerations in minimizing wear [J].
Argenson, Jean-Noel A. ;
Parratte, Sebastien .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (452) :137-142
[6]   Investigation of wear of knee prostheses in a new displacement/force-controlled simulator [J].
Barnett, PI ;
McEwen, HMJ ;
Auger, DD ;
Stone, MH ;
Ingham, E ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H1) :51-61
[7]  
BLUNN GW, 1991, CLIN ORTHOP RELAT R, P253
[8]   In Vivo Kinematics and Kinetics of a Bi-Cruciate Substituting Total Knee Arthroplasty: A Combined Fluoroscopic and Gait Analysis Study [J].
Catani, Fabio ;
Ensini, Andrea ;
Belvedere, Claudio ;
Feliciangeli, Alessandro ;
Benedetti, Maria Grazia ;
Leardini, Alberto ;
Giannini, Sandro .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2009, 27 (12) :1569-1575
[9]   MOLECULAR-ORIENTATION OF HIGH-DENSITY POLYETHYLENE FIBERS CHARACTERIZED BY POLARIZED RAMAN-SPECTROSCOPY [J].
CITRA, MJ ;
CHASE, DB ;
IKEDA, RM ;
GARDNER, KH .
MACROMOLECULES, 1995, 28 (11) :4007-4012
[10]   Plasticity-induced damage layer is a precursor to wear in radiation-cross-linked UHMWPE acetabular components for total hip replacement [J].
Edidin, AA ;
Pruitt, L ;
Jewett, CW ;
Crane, DJ ;
Roberts, D ;
Kurtz, SM .
JOURNAL OF ARTHROPLASTY, 1999, 14 (05) :616-627