Oesophageal electrocardiography in healthy horses

被引:2
作者
Verheyen, T. [1 ]
Decloedt, A. [1 ]
De Clercq, D. [1 ]
Sys, S. [1 ]
Van Loon, G. [1 ]
机构
[1] Univ Ghent, Fac Vet Med, Dept Large Anim Internal Med, Merelbeke, Belgium
关键词
horse; cardiology; electrodes; unipolar; ATRIAL-FIBRILLATION; ELECTRODE; ECG; CATHETER; LEADS; WAVE;
D O I
10.1111/j.2042-3306.2011.00526.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Reasons for performing study: In human medicine, oesophageal electrocardiography (ECG) is a well-established technique that magnifies P waves with respect to the QRS complex. Objectives: To investigate the feasibility of oesophageal ECG recording in horses and its ability to produce larger P waves compared with base-apex and unipolar recordings. Methods: Bipolar and unipolar ECG were performed using oesophageal and surface electrodes. Oesophageal ECG was obtained from 6 different recording configurations at different oesophageal depths. Amplitudes of P, Q, R, S and T waves were measured from 3 different cardiac cycles for each recording configuration and depth. Results: Oesophageal ECG was feasible in all horses. For all oesophageal recording configurations, significantly larger P waves were recorded from a depth that equalled height of the withers + 10 cm (HW+10) than from any other depth. P/QRS(magn), the ratio between the P wave and QRS complex magnitudes, was largest for intraoesophageal recordings with an interelectrode distance of 10 cm, at HW+10, where it was significantly larger than base-apex and unipolar recordings. Base-apex recording resulted in significantly smaller P waves than all other recording configurations and significantly smaller P/QRS(magn) ratios than all other recording configurations except one combined oesophageal-surface recording (E/S-low). Conclusions: Oesophageal ECG recording is feasible in horses and effective in magnifying P wave amplitude. Potential relevance: The procedure is promising for diagnosis of supraventricular tachydysrhythmias and might be used in electrophysiological studies and for cardiac pacing.
引用
收藏
页码:640 / 645
页数:6
相关论文
共 27 条
[1]  
ARZBAECHER R, 1978, MED INSTRUM, V12, P277
[2]   Comparison of the amplitude of the P-wave from intracardiac electrocardiogram obtained by means of a central venous catheter filled with saline solution to that obtained via esophageal electrocardiogram [J].
Benzadon, Mariano Noel ;
Ortega, Daniel Felipe ;
Thierer, Jorge Mario ;
Spampinato Torcivia, Ricardo Adolfo ;
Aldunate, Leandro ;
Alves de Lima, Alberto Enrique ;
Navia, Daniel ;
Dorsa, Alberto ;
Rossi, Adriana ;
Trivi, Marcelo .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (07) :978-981
[3]   INVIVO VALIDATION OF THE ORIGIN OF THE ESOPHAGEAL ELECTROCARDIOGRAM [J].
BINKLEY, PF ;
BUSH, CA ;
FLEISHMAN, BL ;
LEIER, CV .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (04) :813-818
[4]   THE PRINCIPLES OF ESOPHAGEAL ELECTROCARDIOGRAPHY [J].
BRODY, DA ;
COPELAND, GD .
AMERICAN HEART JOURNAL, 1959, 57 (01) :3-18
[5]   Cardiac arrhythmias in clinically healthy showjumping horses [J].
Buhl, R. ;
Meldgaard, C. ;
Barbesgaard, L. .
EQUINE VETERINARY JOURNAL, 2010, 42 :196-201
[6]  
COPELAND GD, 1959, AM HEART J, V57, P862
[7]   Atrial and Ventricular Electrical and Contractile Remodeling and Reverse Remodeling Owing to Short-Term Pacing-Induced Atrial Fibrillation in Horses [J].
De Clercq, D. ;
van Loon, G. ;
Tavernier, R. ;
Duchateau, L. ;
Deprez, Piet .
JOURNAL OF VETERINARY INTERNAL MEDICINE, 2008, 22 (06) :1353-1359
[8]   ESOPHAGEAL PACING - A DIAGNOSTIC AND THERAPEUTIC TOOL [J].
GALLAGHER, JJ ;
SMITH, WM ;
KERR, CR ;
COOK, JKL ;
REITER, M ;
STERBA, R ;
HARTE, M .
CIRCULATION, 1982, 65 (02) :336-341
[9]   ATRIAL ACTIVATION PATHS AND P-WAVES IN HORSES [J].
HAMLIN, RL ;
SMETZER, DL ;
SENTA, T ;
SMITH, CR .
AMERICAN JOURNAL OF PHYSIOLOGY, 1970, 219 (02) :306-&
[10]   SIMPLIFIED ESOPHAGEAL ELECTROCARDIOGRAPHY USING BIPOLAR RECORDING LEADS [J].
HAMMILL, SC ;
PRITCHETT, ELC .
ANNALS OF INTERNAL MEDICINE, 1981, 95 (01) :14-18