Management of Occluded Metal Stents in Malignant Biliary Obstruction: Similar Outcomes with Second Metal Stents Compared to Plastic Stents

被引:28
作者
Shah, Tilak [1 ,2 ]
Desai, Svetang [1 ,2 ]
Haque, Mahfuzul [1 ,2 ]
Dakik, Hassan [1 ,2 ]
Fisher, Deborah [1 ,2 ]
机构
[1] Duke Univ, Med Ctr, Div Gastroenterol, Box 3913, Durham, NC 27710 USA
[2] Durham VA Med Ctr, Durham, NC USA
关键词
Endoscopic retrograde cholangiopancreatography; Stents; Obstructive jaundice; Extrahepatic cholestasis; Neoplasms; ENDOSCOPIC MANAGEMENT; DIAMOND STENTS; BILE-DUCT; PALLIATION; METAANALYSIS; TRIAL;
D O I
10.1007/s10620-012-2272-7
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Covered or uncovered self expandable metallic stents (SEMS) placed in patients with malignant biliary obstruction can occlude in 19-40 %, but optimal management is unclear. We sought to summarize current evidence regarding management of occluded SEMS in patients with malignant biliary obstruction. Two investigators independently searched Pubmed, Embase, and Web of Science using pre-defined search criteria, and reviewed bibliographies of included studies. Data were independently abstracted by two investigators, and analyzed using RevMan. We compared strategies of second SEMS versus plastic stents with respect to the following outcomes: rate of second stent re-occlusion, duration of second stent patency, and survival. Ten retrospective studies met inclusion criteria for the systematic review. Management options described were placement of an uncovered SEMS (n = 125), covered SEMS (n = 106), plastic stent (n = 135), percutaneous biliary drain (n = 7), mechanical cleaning (n = 18), or microwave coagulation (n = 7). Relative risk of re-occlusion was not significantly different in patients with second SEMS compared to plastic stents (RR 1.24, 95 % CI 0.92, 1.67, I-2 = 0, p 0.16). Duration of second stent patency was not significantly different between patients who received second SEMS versus plastic stents (weighted mean difference 0.46, 95 % CI -0.30, 1.23, I-2 = 83 %). Survival was not significantly different among patients who received plastic stents versus SEMS (weighted mean difference -1.13, 95 % CI -2.33, 0.07, I-2 86 %, p = 0.07). Among patients with malignant biliary obstruction and occluded SEMS, available evidence suggests a strategy of placing a plastic stent may be as effective as second SEMS. Limitations of these findings were that all studies were retrospective and heterogeneity between studies was detected for two of the outcomes.
引用
收藏
页码:2765 / 2773
页数:9
相关论文
共 22 条
  • [1] Effectiveness of the ultraflex diamond stent for the palliation of malignant biliary obstruction
    Ahmad, J
    Siqueira, E
    Martin, J
    Slivka, A
    [J]. ENDOSCOPY, 2002, 34 (10) : 793 - 796
  • [2] Comparison of outcomes among secondary covered metallic, uncovered metallic, and plastic biliary stents in treating occluded primary metallic stents in malignant distal biliary obstruction
    Cho, Jae Hee
    Jeon, Tae Joo
    Park, Jeong Youp
    Kim, Hee Man
    Kim, Yoon Jae
    Park, Seung Woo
    Chung, Jae Bock
    Song, Si Young
    Bang, Seungmin
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2011, 25 (02): : 475 - 482
  • [3] RANDOMIZED TRIAL OF SELF-EXPANDING METAL STENTS VERSUS POLYETHYLENE STENTS FOR DISTAL MALIGNANT BILIARY OBSTRUCTION
    DAVIDS, PHP
    GROEN, AK
    RAUWS, EAJ
    TYTGAT, GNJ
    HUIBREGTSE, K
    [J]. LANCET, 1992, 340 (8834-5) : 1488 - 1492
  • [4] METAANALYSIS IN CLINICAL-TRIALS
    DERSIMONIAN, R
    LAIRD, N
    [J]. CONTROLLED CLINICAL TRIALS, 1986, 7 (03): : 177 - 188
  • [5] Dumonceau JM, 2000, AM J GASTROENTEROL, V95, P670
  • [6] Diamond stents for palliation of malignant bile duct obstruction:: A prospective multicenter evaluation
    Ferlitsch, A
    Oesterreicher, C
    Dumonceau, JM
    Deviere, J
    Leban, T
    Born, P
    Rösch, T
    Suter, W
    Binek, J
    Meyenberger, C
    Müllner, M
    Schneider, B
    Schöfl, R
    [J]. ENDOSCOPY, 2001, 33 (08) : 645 - 650
  • [7] Gargouri Dalila, 2010, Tunis Med, V88, P462
  • [8] Estimating the mean and variance from the median, range, and the size of a sample
    Hozo S.P.
    Djulbegovic B.
    Hozo I.
    [J]. BMC Medical Research Methodology, 5 (1)
  • [9] Plastic or metal stents for malignant stricture of the common bile duct? Results of a randomized prospective study
    Kaassis, M
    Boyer, J
    Dumas, R
    Ponchon, T
    Coumaros, D
    Delcenserie, R
    Canard, JM
    Fritsch, J
    Rey, JF
    Burtin, P
    [J]. GASTROINTESTINAL ENDOSCOPY, 2003, 57 (02) : 178 - 182
  • [10] Endoscopic management of occluded biliary uncovered metal stents: multicenter experience
    Katsinelos, Panagiotis
    Beltsis, Athanasios
    Chatzimavroudis, Grigoris
    Paikos, Dimitris
    Paroutoglou, George
    Kapetanos, Dimitris
    Terzoudis, Sotiris
    Lazaraki, Georgia
    Pilpilidis, Ioannis
    Fasoulas, Kostas
    Atmatzidis, Stefanos
    Zavos, Christos
    Kountouras, Jannis
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2011, 17 (01) : 98 - 104