摘要
Clinical cases show that zirconia restoration could happen fracture by accident under overloading after using a period of time. The purpose of this study is to research mechanical behavior and predict lifetime of dental zirconia ceramics under cyclic normal contact loading with experiments. Cyclic normal contact loading test and three point bending test are carried on specimens made of two brands of dental zirconia ceramic to obtain flexure strength and damage degree after different number of loading cycles. By means of damage mechanics model, damage degree under different number of contact loading cycles are calculated according to flexure strength, and verified by SEM photographs of cross section morphology of zirconia ceramics specimen phenomenologically. Relation curve of damage degree and number of cycles is fitted by polynomial fitting, then the number of loading cycles can be concluded when the specimen is complete damage. Strength degradation of two brands dental zirconia ceramics are researched in vitro, and prediction method of contact fatigue lifetime is established.
引用
收藏
页码:S129 / S137
页数:9
相关论文
共 35 条
[1]   Fatigue and Fracture Resistance of Zirconia Crowns Prepared with Different Finish Line Designs [J].
Aboushelib, Moustafa N. .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (01) :22-27
[2]   Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs) [J].
Beuer, Florian ;
Edelhoff, Daniel ;
Gernet, Wolfgang ;
Sorensen, John A. .
CLINICAL ORAL INVESTIGATIONS, 2009, 13 (04) :445-451
[3]   Fatigue and subcritical crack growth in ZrO2-bioglass ceramics [J].
Bicalho, L. A. ;
Baptista, C. A. R. P. ;
Souza, R. C. ;
Santos, C. ;
Strecker, K. ;
Barboza, M. J. R. .
CERAMICS INTERNATIONAL, 2013, 39 (03) :2405-2414
[4]   Five-year clinical evaluation of zirconia-based bridges in patients in UK general dental practices [J].
Burke, F. J. T. ;
Crisp, R. J. ;
Cowan, A. J. ;
Lamb, J. ;
Thompson, O. ;
Tulloch, N. .
JOURNAL OF DENTISTRY, 2013, 41 (11) :992-999
[5]   Hertzian cone crack propagation on polycrystalline materials:: Role of R-curve and residual stresses [J].
Ceseracciu, L. ;
Anglada, M. ;
Jimenez-Pique, E. .
ACTA MATERIALIA, 2008, 56 (02) :265-273
[6]   A Novel Computer-Aided Method to Fabricate a Custom One-Piece Glass Fiber Dowel-and-Core Based on Digitized Impression and Crown Preparation Data [J].
Chen, Zhiyu ;
Li, Ya ;
Deng, Xuliang ;
Wang, Xinzhi .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (04) :276-283
[7]   Current ceramic materials and systems with clinical recommendations: A systematic review [J].
Conrad, Heather J. ;
Seong, Wook-Jin ;
Pesun, Gor J. .
JOURNAL OF PROSTHETIC DENTISTRY, 2007, 98 (05) :389-404
[8]   Stress distribution and failure mode of dental ceramic structures under Hertzian indentation [J].
Dong, XD ;
Darvell, BW .
DENTAL MATERIALS, 2003, 19 (06) :542-551
[9]   FATIGUE IN CERAMICS [J].
EVANS, AG .
INTERNATIONAL JOURNAL OF FRACTURE, 1980, 16 (06) :485-498
[10]   Sphere contact fatigue of a coarse-grained Al2O3 ceramic [J].
Fett, T. ;
Ernst, E. ;
Rizzi, G. ;
Munz, D. ;
Badenheim, D. ;
Oberacker, R. .
FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES, 2006, 29 (11) :876-886