Analysis of benzalkonium chloride and its homologs: HPLC versus HPCE

被引:46
作者
Prince, SJ
McLaury, HJ
Allen, LV
McLaury, P
机构
[1] SW Oklahoma State, Sch Pharm, Weatherford, OK 73096 USA
[2] Parke Davis Pharmaceut, Morris Plains, NJ 07950 USA
[3] Univ Oklahoma, Coll Pharm, Oklahoma City, OK 73117 USA
[4] Novartis Pharmaceut Corp, E Hanover, NJ 07936 USA
关键词
benzalkonium chloride; high performance liquid chromatography; high performance capillary electrophoresis;
D O I
10.1016/S0731-7085(98)00187-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Benzalkonium chloride (BAK) is a mixture of alkyllaenzyldimethylammonium chloride homologs with n-C12H25, n-C14H29, and n-C16H33 comprising a major portion of the alkyl groups present. An analytical method for BAK must differentiate and quantitate the homologs in the BAK mixture. Reversed-phase high performance liquid chromatography (HPLC) separates compounds based on their affinity for a nonpolar column, which is a direct correlation to the compounds' polarity. High performance capillary electrophoresis (HPCE), however, separates compounds in an electric field according to their charge and size. The BAK homologs are suitable for separation by either of these methods because their polarity and sizes differ significantly. The HPLC method employed a mobile phase of 60% acetonitrile and 40% 0.1 M sodium acetate buffer pH 5 pumped at 1.0 mi min(-1), a 4.6 x 250 mm cyano column with 5 mu m packing, and UV detection at 254 nm. The HPCE method utilized a run buffer of 30% acetonitrile and 70% 0.05 M sodium phosphate pH 3.06, a 50 mu m x 20 cm open silica capillary, 7.5 kV electric field and UV detection at 214 nm. Both HPLC and HPCE demonstrated good linearity in the range of 0.025 to 0.8 mg ml(-1) with r(2) values of approximately 0.99. The HPLC method produced good separation of the homolog peaks with a total analysis time of 25 min. HPCE run time was less than 5 min and demonstrated good separation of the three homologs. The HPLC method, however, was superior to HPCE in the areas of sensitivity and precision. The HPLC has been extensively used in the routine quantitation and qualitation of benzalkonium chloride concentrations in various products; however, long analysis times make this method inefficient. The HPCE method produced comparable results to the HPLC method but with much shorter analysis times. An HPCE analysis method, as presented here, may prove to be a much more useful and efficient method for the analysis of benzalkonium chloride and its homologs. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:877 / 882
页数:6
相关论文
共 15 条
[1]   Validated capillary electrophoretic method for the quantitative analysis of histamine acid phosphate and/or benzalkonium chloride [J].
Altria, KD ;
Elgey, J ;
Howells, JS .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 686 (01) :111-117
[2]   DIRECT DETERMINATION OF BENZALKONIUM CHLORIDE IN OPHTHALMIC SYSTEMS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
AMBRUS, G ;
TAKAHASHI, LT ;
MARTY, PA .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1987, 76 (02) :174-176
[3]   DETERMINATION OF DEMECARIUM BROMIDE AND RELATED-COMPOUNDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
COHN, LJ ;
GREELY, VJ ;
TIBBETTS, DL .
JOURNAL OF CHROMATOGRAPHY, 1985, 321 (02) :401-405
[4]   DETERMINATION OF BENZALKONIUM CHLORIDE IN EYE CARE PRODUCTS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND SOLID-PHASE EXTRACTION OR ONLINE COLUMN SWITCHING [J].
ELROD, L ;
GOLICH, TG ;
MORLEY, JA .
JOURNAL OF CHROMATOGRAPHY, 1992, 625 (02) :362-367
[5]  
EUERBY MR, 1985, J CLIN HOSP PHARM, V10, P73
[6]   DETERMINATION OF BENZALKONIUM CHLORIDE IN OPHTHALMIC SOLUTIONS CONTAINING TYLOXAPOL BY SOLID-PHASE EXTRACTION AND REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
FAN, TY ;
WALL, GM .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1993, 82 (11) :1172-1174
[7]   DETERMINATION OF BENZALKONIUM CHLORIDE IN AQUEOUS OPHTHALMIC PREPARATIONS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GOMEZGOMAR, A ;
GONZALEZAUBERT, MM ;
GARCESTORRENTS, J ;
COSTASEGARRA, J .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1990, 8 (8-12) :871-876
[8]  
Hecht G, 1995, REMINGTON SCI PRACTI, P1563
[9]  
HEIGER DN, 1992, HIGH PERFORMANCE CAP, P32
[10]   DETERMINATION OF BENZALKONIUM CHLORIDE IN THE PRESENCE OF INTERFERING ALKALOIDS AND POLYMERIC SUBSTRATES BY REVERSE-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
MARSH, DF ;
TAKAHASHI, LT .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1983, 72 (05) :521-525