Tissue Visualization Using X-Ray Dark-Field Imaging towards Pathological Goal

被引:1
作者
Ando, Masami [1 ]
Chikaura, Yoshinori [2 ]
Endo, Tokiko [3 ]
Gupta, Rajiv [4 ]
Huo, Qingkai [1 ]
Hyodo, Kazuyuki [5 ]
Ichihara, Shu [3 ]
Mori, Kensaku [6 ]
Nakao, Yuki [1 ]
Ohura, Norihiko [7 ]
Sunaguchi, Naoki [5 ]
Sugiyama, Hiroshi [5 ]
Suzuki, Yoshifumi [8 ]
Wu, Yanlin [9 ]
Yuasa, Tetsuya [10 ]
Zhang Xiaowei
机构
[1] Tokyo Univ Sci, Yamasaki 2461, Noda, Chiba 2788510, Japan
[2] Kyushu Univ, Res Ctr Synchrotron Light Applicat, Kasuga, Fukuoka 8168580, Japan
[3] Nagoya Med Ctr, Dept Adv Diag, Naka Ku, Nagoya, Aichi 4600001, Japan
[4] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 01778 USA
[5] KEK, Photon Factory, Ibaraki 3050801, Japan
[6] Nagoya Univ, Grd Sch Informat Sci, Nagoya, Aichi 4648603, Japan
[7] Kyorin Univ, Sch Med, Dept Plast Surg, Mitaka, Tokyo 1810001, Japan
[8] Kyushu Inst Technol, Grd Sch Engn, Kitakyushu, Fukuoka 8048550, Japan
[9] Grd Univ Sci, Sch Accelerator Sci, Tsukuba, Ibaraki 3050801, Japan
[10] Yamagata Univ, Fac Engn, Yonezawa, Yamagata 9928510, Japan
来源
11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012) | 2013年 / 425卷
关键词
COMPUTED-TOMOGRAPHY; PHASE-CONTRAST; RECONSTRUCTION;
D O I
10.1088/1742-6596/425/19/192006
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In XDFI (x-ray dark-field imaging) LAA (Laue-case angle analyzer) simultaneously provides two x-ray images; one corresponds to a FD forward diffracted beam and a separate D diffracted beam. When this is applied to biomedical specimens x-ray images are very high contrast and very high spatial resolution. We constructed XDFI system at the vertical wiggler beamline BL-14C in KEK Photon Factory and performed imaging experiment of breast tissues and an excised human femoral artery. In this paper, we discuss a tissue visualization and pathological goal using 2D, 3D-CT and 2.5D image (tomosynthesis) with XDFI.
引用
收藏
页数:4
相关论文
共 15 条
[1]   DESIGN OF BEAMLINE 14 FOR THE PF VERTICAL WIGGLER AND ITS OPERATION [J].
ANDO, M ;
SATOW, Y ;
KAWATA, H ;
ISHIKAWA, T ;
SPIEKER, P ;
SUZUKI, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :144-148
[2]   Simple X-ray dark- and bright-field imaging using achromatic lane optics [J].
Ando, M ;
Maksimenko, A ;
Sugiyama, H ;
Pattanasiriwisawa, W ;
Hyodo, K ;
Uyama, C .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2002, 41 (9A-B) :L1016-L1018
[3]   Diffraction enhanced x-ray imaging [J].
Chapman, D ;
Thomlinson, W ;
Johnston, RE ;
Washburn, D ;
Pisano, E ;
Gmur, N ;
Zhong, Z ;
Menk, R ;
Arfelli, F ;
Sayers, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2015-2025
[4]  
CHAPMAN D, 1996, REV SCI INSTRUM, V67, P3360
[5]   Computed tomography of x-ray index of refraction using the diffraction enhanced imaging method [J].
Dilmanian, FA ;
Zhong, Z ;
Ren, B ;
Wu, XY ;
Chapman, LD ;
Orion, I ;
Thomlinson, WC .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (04) :933-946
[6]   Direct computed tomographic reconstruction for directional-derivative projections of computed tomography of diffraction enhanced imaging [J].
Huang, Zhi-Feng ;
Kang, Ke-Jun ;
Li, Zheng ;
Zhu, Pei-Ping ;
Yuan, Qing-Xi ;
Huang, Wan-Xia ;
Wang, Jun-Yue ;
Zhang, Di ;
Yu, Ai-Min .
APPLIED PHYSICS LETTERS, 2006, 89 (04)
[7]   X-RAY PLANE-WAVE TOPOGRAPHY OBSERVATION OF THE PHASE-CONTRAST FROM A NONCRYSTALLINE OBJECT [J].
INGAL, VN ;
BELIAEVSKAYA, EA .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1995, 28 (11) :2314-2317
[8]   Computed tomographic reconstruction based on x-ray refraction contrast [J].
Maksimenko, A ;
Ando, M ;
Hiroshi, S ;
Yuasa, T .
APPLIED PHYSICS LETTERS, 2005, 86 (12) :1-3
[9]   Demonstration of X-Ray Talbot interferometry [J].
Momose, A ;
Kawamoto, S ;
Koyama, I ;
Hamaishi, Y ;
Takai, K ;
Suzuki, Y .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2003, 42 (7B) :L866-L868
[10]  
Mori K, 1996, IEICE T INF SYST, VE79D, P809