Effect of display monitor devices on intra-oral radiographic caries diagnosis

被引:11
作者
Araki, Kazuyuki [1 ]
Fujikura, Mamiko [1 ]
Sano, Tsukasa [1 ]
机构
[1] Showa Univ, Sch Dent, Dept Oral Diagnost Sci, Div Radiol,Ohta Ku, Tokyo 1458515, Japan
关键词
Digital radiography; Receiver operating characteristic curve analysis; Dental caries; Monitor; Diagnostic accuracy; DIGITAL RADIOGRAPHS; PERFORMANCE; SYSTEM; IPAD; ROC;
D O I
10.1007/s00784-015-1401-z
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives Recent developments in digital computer technology have enabled radiological diagnosis to be performed using a monitor screen. In medical radiography, the importance of monitors has been shown in many diseases. Digital imaging and communication in medicine (DICOM)-compatible monitors are widely used. However, the effect of monitors on the diagnosis of oral disease has not yet been clarified and remains controversial. The aims of this study are to compare the caries diagnostic ability between DICOM monitors and other monitors and to examine if monitor capability affects the diagnosis. Materials and methods One hundred proximal surfaces of 50 extracted human upper premolar teeth were used as specimens. Intra-oral radiographs of all specimens were taken digitally. Three types of monitors were compared in terms of caries diagnostic ability: a DICOM standard-compatible monitor, a standardized personal computer (PC) monitor, and a tablet PC. Six oral radiologists diagnosed each radiograph independently. Areas under the receiver operating characteristic (ROC) curve were generated and compared. Results Area under the ROC curve (AUC) of the DICOM monitor, PC monitor, and tablet PC was 0.68147, 0.67002, and 0.60189, respectively. There was no significant difference between the DICOM monitor and the PC monitor, but the tablet PC showed significantly lower accuracy. There were no significant differences among the monitors for dentin caries (p > 0.05). Conclusions DICOM-compatible monitors and PC monitors have similar capabilities, but tablet PCs showed lower diagnostic accuracy, especially for superficial caries.
引用
收藏
页码:1875 / 1879
页数:5
相关论文
共 14 条
[1]   TB or Not TB: Interreader and Intrareader Variability in Screening Diagnosis on an iPad versus a Traditional Display [J].
Abboud, Samir ;
Weiss, Frederick ;
Siegel, Eliot ;
Jeudy, Jean .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2013, 10 (01) :42-44
[2]   Influence of display quality on radiologists' performance in the detection of lung nodules on radiographs [J].
Buls, N. ;
Shabana, W. ;
Verbeek, P. ;
Pevenage, P. ;
De Mey, J. .
BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (957) :738-743
[3]  
Espelid I, 2003, Eur J Paediatr Dent, V4, P40
[4]   Effect of monitors on approximal caries detection in digital radiographs-standard versus precalibrated DICOM part 14 displays: An in vitro study [J].
Hellen-Halme, Kristina ;
Nilsson, Mats ;
Petersson, Arne .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (05) :716-720
[5]   Recent developments in the Dorfman-Berbaum-Metz procedure for multireader ROC study analysis [J].
Hillis, Stephen L. ;
Berbaum, Kevin S. ;
Metz, Charles E. .
ACADEMIC RADIOLOGY, 2008, 15 (05) :647-661
[6]   Detection of Artificial Occlusal Caries in a Phosphor Imaging Plate System with Two Types of LCD Monitors Versus Three Different Films [J].
Ilguy, Mehmet ;
Dincer, Semanur ;
Ilguy, Dilhan ;
Bayirli, Zuenduez .
JOURNAL OF DIGITAL IMAGING, 2009, 22 (03) :242-249
[7]   Effect of monitor display on detection of approximal caries lesions in digital radiographs [J].
Isidor, S. ;
Faaborg-Andersen, M. ;
Hintze, H. ;
Kirkevang, L-L ;
Frydenberg, M. ;
Haiter-Neto, F. ;
Wenzel, A. .
DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (08) :537-541
[8]   Diagnostic performance in differentiation of breast lesion on digital mammograms: comparison among hard-copy film, 3-megapixel LCD monitor, and 5-megapixel LCD monitor [J].
Kamitani, Takeshi ;
Yabuuchi, Hidetake ;
Matsuo, Yoshio ;
Setoguchi, Taro ;
Sakai, Shuji ;
Okafuji, Takashi ;
Sunami, Shunya ;
Hatakenaka, Masamitsu ;
Ishii, Nobuhide ;
Kubo, Makoto ;
Tokunaga, Eriko ;
Yamamoto, Hidetaka ;
Honda, Hiroshi .
CLINICAL IMAGING, 2011, 35 (05) :341-345
[9]   Use of a human visual system model to predict observer performance with CRT vs LCD display of images [J].
Krupinski, EA ;
Johnson, J ;
Roehrig, H ;
Nafziger, J ;
Fan, JH ;
Lubin, J .
JOURNAL OF DIGITAL IMAGING, 2004, 17 (04) :258-263
[10]   ROC analysis for diagnostic accuracy of fracture by using different monitors [J].
Liang, Zhigang ;
Li, Kuncheng ;
Yang, Xiaolin ;
Du, Xiangying ;
Liu, Jiabin ;
Zhao, Xin ;
Qi, Xiangdong .
JOURNAL OF DIGITAL IMAGING, 2006, 19 (03) :276-278