High-Resolution Maps of Magnetization Transfer with Inherent Correction for RF Inhomogeneity and T1 Relaxation Obtained from 3D FLASH MRI

被引:248
作者
Helms, Gunther [1 ]
Dathe, Henning [2 ]
Kallenberg, Kai [1 ,3 ]
Dechent, Peter [1 ]
机构
[1] Univ Med Gottingen, MR Forsch Neurol & Psychiat, D-37075 Gottingen, Germany
[2] AG Biomech, Abt Kieferorthopad, Gottingen, Germany
[3] Univ Med Gottingen, Abt Neuroradiol, Gottingen, Germany
关键词
magnetization transfer; relaxation; saturation; human brain; multiple sclerosis;
D O I
10.1002/mrm.21732
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
empirical equation for the magnetization transfer (MT) FLASH signal is derived by analogy to dual-excitation FLASH introducing a novel semiquantitative parameter for MT, the per centage saturation imposed by one MT pulse during TR. This parameter is obtained by a linear transformation of the inverse signal, using two reference experiments of proton density and T, weighting. The influence of sequence parameters on the MT saturation was studied. An 8.5-min protocol for brain imaging a 3 T was based on nonselective sagittal 3D-FLASH at 1.25 mm isotropic resolution using partial acquisition techniques (TRITE alpha = 25ms/4.9ms/5 degrees or 11 ms/4.9ms/15 degrees for the T-1 reference). 12.8 ms Gaussian MT pulse was applied 2.2 kHz off-resonance with 540 degrees flip angle. The MT saturation maps showed an excel lent contrast in the brain due to clearly separated distributiom for white and gray matter and cerebrospinal fluid. Within the limits of the approximation (excitation <15 degrees, TR/T-1 << 1) the MT term depends mainly on TR, the energy and offset of the MT pulse, but hardly on excitation and T, relaxation. It is inherently compensated for inhomogeneities of receive and transmit RF fields. The MT saturation appeared to be a sensitive parameter to depict MS lesions and alterations of normal-appearing white matter. Magn Reson Med 60:1396-1407, 2008. (C) 2008 Wiley Liss, Inc.
引用
收藏
页码:1396 / 1407
页数:12
相关论文
共 20 条
[1]   Optimisation of the 3D MDEFT sequence for anatomical brain imaging: Technical implications at 1.5 and 3 T [J].
Deichmann, R ;
Schwarzbauer, C ;
Turner, R .
NEUROIMAGE, 2004, 21 (02) :757-767
[2]  
EDZES HT, 1978, J MAGN RESON, V31, P207, DOI 10.1016/0022-2364(78)90185-3
[3]   Understanding pulsed magnetization transfer [J].
Graham, SJ ;
Henkelman, RM .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (05) :903-912
[4]   Simultaneous measurement of saturation and relaxation in human brain by repetitive magnetization transfer pulses [J].
Helms, G ;
Piringer, A .
NMR IN BIOMEDICINE, 2005, 18 (01) :44-50
[5]   Quantitative magnetization transfer by trains of radio frequency pulses in human brain: extension of a free evolution model to continuous-wave-like conditions [J].
Helms, G ;
Piringer, A .
MAGNETIC RESONANCE IMAGING, 2005, 23 (06) :723-731
[6]   Pulsed saturation of the standard two-pool model for magnetization transfer. Part I: The steady state [J].
Helms, G ;
Hagberg, GE .
CONCEPTS IN MAGNETIC RESONANCE PART A, 2004, 21A (01) :37-49
[7]   Magnetization transfer of water T2 relaxation components in human brain:: implications for T2-based segmentation of spectroscopic volumes [J].
Helms, G ;
Piringer, A .
MAGNETIC RESONANCE IMAGING, 2001, 19 (06) :803-811
[8]   Rapid radiofrequency field mapping in vivo using single-shot STEAM MRI [J].
Helms, Gunther ;
Finsterbusch, Jurgen ;
Weiskopf, Nikolaus ;
Dechent, Peter .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) :739-743
[9]   Quantitative FLASH MRI at 3T using a rational approximation of the Ernst equation [J].
Helms, Gunther ;
Dathe, Henning ;
Dechent, Peter .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (03) :667-672
[10]   Interaction of exchange and differential relaxation in the saturation recovery behavior of the binary spin-bath model for magnetization transfer [J].
Helms, Gunther .
CONCEPTS IN MAGNETIC RESONANCE PART A, 2006, 28A (04) :291-298