5-methyltetrahydrofolic acid and folic acid measured in plasma with liquid chromatography tandem mass spectrometry: applications to folate absorption and metabolism

被引:65
|
作者
Kok, RM
Smith, DEC
Dainty, JR
van den Akker, JT
Finglas, PM
Smulders, YM
Jakobs, C
de Meer, K [1 ]
机构
[1] Vrije Univ Amsterdam, Ctr Med, Dept Clin Chem, NL-1007 MB Amsterdam, Netherlands
[2] Food Res Inst, Norwich, Norfolk, England
[3] Vrije Univ Amsterdam, Ctr Med, Dept Internal Med, NL-1007 MB Amsterdam, Netherlands
关键词
folate; liquid chromatography tandem mass spectrometry; bioavailability;
D O I
10.1016/j.ab.2003.12.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We describe a liquid chromatography (LC) tandem mass spectrometry (MS-MS) method for the determination of 5-methyltetrahydrofolic acid (5-methylTHF) and folic acid concentrations and enrichments in human plasma. It was used to study absorption and initial metabolism in five volunteers with two simultaneously administered oral test doses ([C-13(6)]folic acid in capsules and [H-2(2)]folic acid in a drink). [C-13(5)]5-methylTHF and [H-2(4)]folic acid were used as internal standards. Plasma samples (2 ml) were purified using folate binding protein affinity columns, followed by a concentration step. After LC separation, folates were detected using positive electrospray ionization MS-MS under multiple reaction monitoring conditions. Calibrations were linear for 5-methylTHF over the range 1.2 x 10(-11) (=limit of detection) to 3.2 x 10(-7) mol/L and for folic acid over the range 5 x 10(-10) (=limit of detection) to 4.5 x 10(-8) mol/L. For 5-methylTHF concentration in plasma, intraassay coefficient of variation was within 8.6% (and for unlabeled 5-methylTHF it was within 2.8%) and interassay coefficient of variation was within 9.0%. For folic acid concentrations these coefficient of variations were within 7.5% and within 6.5%, respectively. The [C-13(6)] and [H-2(2)] isotopomers of folic acid and 5-methylTHF were measured in the plasma of each volunteer for 8 It. After accounting for the time delay due to capsule opening, the modeling results showed no significant differences in absorption time, first pass effect, and elimination rate in the folic acid test doses in capsule or drink. We conclude that LC-MS-MS offers increased sensitivity for quantification of plasma concentrations and enrichments of 5-methylTHF and folic, acid and is applicable to stable-isotope studies in humans. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:129 / 138
页数:10
相关论文
共 50 条
  • [21] Role of folate receptor and reduced folate carrier in the transport of 5-methyltetrahydrofolic acid in human ovarian carcinoma cells
    Corona, G
    Giannini, F
    Fabris, M
    Toffoli, G
    Boiocchi, M
    INTERNATIONAL JOURNAL OF CANCER, 1998, 75 (01) : 125 - 133
  • [22] EFFECTS OF ACUTE ETHANOL ON URINARY-EXCRETION OF 5-METHYLTETRAHYDROFOLIC ACID AND FOLATE DERIVATIVES IN THE RAT
    EISENGA, BH
    COLLINS, TD
    MCMARTIN, KE
    JOURNAL OF NUTRITION, 1989, 119 (10): : 1498 - 1505
  • [23] Simultaneous determination of folic acid photolysis products and oxidized guanine derivatives in plasma by liquid chromatography-tandem mass spectrometry
    Li, Juan
    Hu, Wenchao
    Liu, Mengxue
    Tian, Yingqi
    He, Manni
    Liu, Hongmin
    JOURNAL OF SEPARATION SCIENCE, 2024, 47 (07)
  • [24] Quantitative determination of folic acid in multivitamin/multielement tablets using liquid chromatography/tandem mass spectrometry
    Nelson, Bryant C.
    Sharpless, Katherine E.
    Sander, Lane C.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1135 (02) : 203 - 211
  • [25] Determination of misoprostol acid in human plasma by liquid chromatography coupled to tandem mass spectrometry
    Zou, Yu
    Chen, Xiaoyan
    Song, Bo
    Zhong, Dafang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 122 - 127
  • [26] Determination of arotinoid acid in human plasma by liquid chromatography-tandem mass spectrometry
    Deng, Pan
    Chen, Xiaoyan
    Tang, Yunbiao
    Wang, Yongqing
    Zhang, Hongwen
    Zhong, Dafang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (27): : 2983 - 2988
  • [27] Quantitative determination of perfluorooctanoic acid in serum and plasma by liquid chromatography tandem mass spectrometry
    Flaherty, JM
    Connolly, PD
    Decker, ER
    Kennedy, SM
    Ellefson, ME
    Reagen, WK
    Szostek, B
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 819 (02): : 329 - 338
  • [28] A validated method to quantify folic acid in wheat flour samples using liquid chromatography - Tandem mass spectrometry
    Martins-Junior, Helio A.
    Wang, Alexandre Y.
    Alabourda, Janete
    Pires, Maria A. E.
    Vega, Oscar B.
    Lebre, Daniel T.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2008, 19 (05) : 971 - 977
  • [29] Determination of Talniflumate and Niflumic Acid in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry
    Wonku Kang
    Kibum Kim
    Analytical Sciences, 2009, 25 : 571 - 574
  • [30] Quantitation of γ-aminobutyric acid in equine plasma by hydrophilic interaction liquid chromatography with tandem mass spectrometry
    Yi, Rong
    Zhao, Sarah
    Kong, Noel
    Zhang, Julia
    Loganathan, Devan
    Merette, Sandrine
    Morrissey, Barbara
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (16) : 3239 - 3247