Optimized dose regimen for whole-body FDG-PET imaging

被引:84
作者
de Groot, Eleonore H. [1 ]
Post, Nieky [2 ]
Boellaard, Ronald [3 ]
Wagenaar, Nils R. L. [2 ]
Willemsen, Antoon T. M. [1 ]
van Dalen, Jorn A. [2 ,4 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, NL-9700 RB Groningen, Netherlands
[2] Ziekenhuisgroep Twente, Dept Nucl Med, NL-7550 AM Hengelo, Netherlands
[3] Vrije Univ Amsterdam, Med Ctr, Dept Radiol & Nucl Med, NL-1081 HV Amsterdam, Netherlands
[4] Isala Klin, Dept Med Phys, NL-8011 JW Zwolle, Netherlands
关键词
Positron-emission tomography; Image quality; Weight dependency; Signal-to-noise ratio; Dose; SCAN DURATION; OVERWEIGHT; PROTOCOLS;
D O I
10.1186/2191-219X-3-63
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The European Association of Nuclear Medicine procedure guidelines for whole-body fluorodeoxyglucose positron-emission tomography (FDG-PET) scanning prescribe a dose proportional to the patient's body mass. However, clinical practice shows degraded image quality in obese patients indicating that using an FDG dose proportional to body mass does not overcome size-related degradation of the image quality. The aim of this study was to optimize the administered FDG dose as a function of the patient's body mass or a different patient-dependent parameter, providing whole-body FDG-PET images of a more constant quality. Methods: Using a linear relation between administered dose and body mass, FDG-PET imaging was performed on two PET/computed tomography scanners (Biograph TruePoint and Biograph mCT, Siemens). Image quality was assessed by the signal-to-noise ratio (SNR) in the liver in 102 patients with a body mass of 46 to 130 kg. Moreover, the best correlating patient-dependent parameter was derived, and an optimized FDG dose regimen was determined. This optimized dose regimen was validated on the Biograph TruePoint system in 42 new patients. Furthermore, this relation was verified by a simulation study, in which patients with different body masses were simulated with cylindrical phantoms. Results: As expected, both PET systems showed a significant decrease in SNR with increasing patient's body mass when using a linear dosage. When image quality was fitted to the patient-dependent parameters, the fit with the patient's body mass had the highest R-2. The optimized dose regimen was found to be A(new) = c/t x m(2), where m is the body mass, t is the acquisition time per bed position and c is a constant (depending on scanner type). Using this relation, SNR no longer varied with the patient's body mass. This quadratic relation between dose and body mass was confirmed by the simulation study. Conclusion: A quadratic relation between FDG dose and the patient's body mass is recommended. Both simulations and clinical observations confirm that image quality remains constant across patients when this quadratic dose regimen is used.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 18 条
[1]   Improved Dose Regimen in Pediatric PET [J].
Accorsi, Roberto ;
Karp, Joel S. ;
Surti, Suleman .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (02) :293-300
[2]   Variations in Clinical PET/CT Operations: Results of an International Survey of Active PET/CT Users [J].
Beyer, Thomas ;
Czernin, Johannes ;
Freudenberg, Lutz S. .
JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (02) :303-310
[3]   FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0 [J].
Boellaard, Ronald ;
O'Doherty, Mike J. ;
Weber, Wolfgang A. ;
Mottaghy, Felix M. ;
Lonsdale, Markus N. ;
Stroobants, Sigrid G. ;
Oyen, Wim J. G. ;
Kotzerke, Joerg ;
Hoekstra, Otto S. ;
Pruim, Jan ;
Marsden, Paul K. ;
Tatsch, Klaus ;
Hoekstra, Corneline J. ;
Visser, Eric P. ;
Arends, Bertjan ;
Verzijlbergen, Fred J. ;
Zijlstra, Josee M. ;
Comans, Emile F. I. ;
Lammertsma, Adriaan A. ;
Paans, Anne M. ;
Willemsen, Antoon T. ;
Beyer, Thomas ;
Bockisch, Andreas ;
Schaefer-Prokop, Cornelia ;
Delbeke, Dominique ;
Baum, Richard P. ;
Chiti, Arturo ;
Krause, Bernd J. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (01) :181-200
[4]   The Netherlands protocol for standardisation and quantification of FDG whole body PET studies in multi-centre trials [J].
Boellaard, Ronald ;
Oyen, Wim J. G. ;
Hoekstra, Corneline J. ;
Hoekstra, Otto S. ;
Visser, Eric P. ;
Willemsen, Antoon T. ;
Arends, Bertjan ;
Verzijlbergen, Fred J. ;
Zijlstra, Josee ;
Paans, Anne M. ;
Comans, Emile F. I. ;
Pruim, Jan .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (12) :2320-2333
[5]   Focus on time-of-flight PET: the benefits of improved time resolution [J].
Conti, Maurizio .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (06) :1147-1157
[6]   State of the art and challenges of time-of-flight PET [J].
Conti, Maurizio .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2009, 25 (01) :1-11
[7]   Improvement in Lesion Detection with Whole-Body Oncologic Time-of-Flight PET [J].
El Fakhri, Georges ;
Surti, Suleman ;
Trott, Cathryn M. ;
Scheuermann, Joshua ;
Karp, Joel S. .
JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (03) :347-353
[8]   Optimal dose of 18F-FDG required for whole-body PET using an LSO PET camera [J].
Everaert, H ;
Vanhove, C ;
Lahoutte, T ;
Muylle, K ;
Caveliers, V ;
Bossuyt, A ;
Franken, PR .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (12) :1615-1619
[9]   Variations in PET/CT Methodology for Oncologic Imaging at US Academic Medical Centers: An Imaging Response Assessment Team Survey [J].
Graham, Michael M. ;
Badawi, Ramsey D. ;
Wahl, Richard L. .
JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (02) :311-317
[10]   SHOULD CLEARANCE BE NORMALIZED TO BODY-SURFACE OR TO LEAN BODY-MASS [J].
HALLYNCK, TH ;
SOEP, HH ;
THOMIS, JA ;
BOELAERT, J ;
DANEELS, R ;
DETTLI, L .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1981, 11 (05) :523-526