Enhanced radiation hardness and signal recovery in thin diamond detectors

被引:13
作者
Skukan, N. [1 ]
Sudic, I. [1 ]
Pomorski, M. [2 ]
Kada, W. [3 ]
Jaksic, M. [1 ]
机构
[1] Rudjer Boskovic Inst, Div Expt Phys, Zagreb 10000, Croatia
[2] CEA, LIST, Diamond Sensors Lab, F-91191 Gif Sur Yvette, France
[3] Gunma Univ, Fac Sci & Technol, Div Elect & Informat, Kiryu, Gunma 3768515, Japan
关键词
11;
D O I
10.1063/1.5081136
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Using the advantage of the high spatial resolution of the Ruder Boskovic Institute (RBI) ion microprobe, small areas of a thin membrane single crystal chemical vapor deposition (scCVD) diamond detector were intentionally damaged with a high-intensity 26-MeV oxygen ion beam at various fluences, producing up to similar to 10(18) vacancies/cm(3). The response of the detector was tested with the ion beam-induced charge technique (IBIC) using a 2-MeV proton beam as a probe. The signal amplitudes decreased down to approximately 50% of the original value at low electric fields (<10 V/mu m) inside the detector. However, the increase of electric field to values of similar to 100 V/mu m completely recovers the signal amplitude. The results presented herein can facilitate the development of true radiation hard particle detectors. (C) 2019 Author(s).
引用
收藏
页数:3
相关论文
共 11 条
  • [1] [Anonymous], THESIS
  • [2] A review of ion beam induced charge microscopy
    Breese, M. B. H.
    Vittone, E.
    Vizkelethy, G.
    Sellin, P. J.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 264 (02) : 345 - 360
  • [3] Radiation hardness study of Silicon Detectors for the CMS High Granularity Calorimeter (HGCAL)
    Curras, E.
    Mannelli, M.
    Moll, M.
    Nourbakhsh, S.
    Steinbrueck, G.
    Vila, I.
    [J]. JOURNAL OF INSTRUMENTATION, 2017, 12
  • [4] Radiation hardness of diamond and silicon sensors compared
    de Boer, Wim
    Bol, Johannes
    Furgeril, Alex
    Mueller, Steffen
    Sander, Christian
    Berdermann, Eleni
    Pomorski, Michal
    Huhtinen, Mika
    [J]. PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2007, 204 (09): : 3004 - 3010
  • [5] Ultrahigh Fluence Radiation Monitoring Technology for the Future Circular Collider at CERN
    Gorine, Georgi
    Pezzullo, Giuseppe
    Mandic, Igor
    Jazbec, Anze
    Snoj, Luka
    Capeans, Mar
    Moll, Michael
    Bouvet, Didier
    Ravotti, Federico
    Sallese, Jean-Michel
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (08) : 1583 - 1590
  • [6] An ultra-thin diamond membrane as a transmission particle detector and vacuum window for external microbeams
    Grilj, V.
    Skukan, N.
    Pomorski, M.
    Kada, W.
    Iwamoto, N.
    Kamiya, T.
    Ohshima, T.
    Jaksic, M.
    [J]. APPLIED PHYSICS LETTERS, 2013, 103 (24)
  • [7] New capabilities of the Zagreb ion microbeam system
    Jaksic, M.
    Radovic, I. Bogdanovc
    Bogovac, M.
    Desnica, V.
    Fazinic, S.
    Karlusic, M.
    Medunic, Z.
    Muto, H.
    Pastuovic, Z.
    Siketic, Z.
    Skukan, N.
    Tadic, T.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 260 (01) : 114 - 118
  • [8] Pomorski M., PHYS STATUS SOLIDI, V203, P3152
  • [9] Super-thin single crystal diamond membrane radiation detectors
    Pomorski, Michal
    Caylar, Benoit
    Bergonzo, Philippe
    [J]. APPLIED PHYSICS LETTERS, 2013, 103 (11)
  • [10] Charge multiplication effect in thin diamond films
    Skukan, N.
    Grilj, V.
    Sudic, I.
    Pomorski, M.
    Kada, W.
    Makino, T.
    Kambayashi, Y.
    Andoh, Y.
    Onoda, S.
    Sato, S.
    Ohshima, T.
    Kamiya, T.
    Jaksic, M.
    [J]. APPLIED PHYSICS LETTERS, 2016, 109 (04)