A CdTe detector for hyperspectral SPECT imaging

被引:22
|
作者
Scuffham, J. W. [1 ,2 ]
Wilson, M. D. [3 ]
Seller, P. [3 ]
Veale, M. C. [3 ]
Sellin, P. J. [2 ]
Jacques, S. D. M. [4 ]
Cernik, R. J. [4 ]
机构
[1] Royal Surrey Cty Hosp, Dept Nucl Med, Guildford, Surrey, England
[2] Univ Surrey, Dept Phys, Guildford GU2 5XH, Surrey, England
[3] Rutherford Appleton Lab, Sci & Technol Facil Council, Didcot, Oxon, England
[4] Univ Manchester, Sch Mat, Manchester, Lancs, England
来源
基金
英国工程与自然科学研究理事会; 美国国家卫生研究院;
关键词
Solid state detectors; Gamma camera; SPECT; PET PET/CT; coronary CT angiography; (CTA); Pixelated detectors and associated VLSI electronics; X-RAY; SYSTEM;
D O I
10.1088/1748-0221/7/08/P08027
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A Cadmium Telluride (CdTe) detector has been developed for multiple-radioisotope SPECT imaging. The 2 x 2 cm detector has 80 x 80 pixels on a 250 mu m pitch and a three-side buttable design so that it can be tiled into larger arrays. The detector is termed hyperspectral as it measures the energy of every photon that interacts in the CdTe to give fully spectroscopic information from 5-200 keV in each pixel. The detector has been tested for applications in multiple-radioisotope SPECT imaging using a 1mm diameter pinhole configuration and standard phantom test objects containing Tc-99m, I-123 and Ga-67. The detector has an average pixel energy resolution (FWHM) of 0.75% at the I-123 photopeak of 159 keV. We demonstrate the system's capability of resolving spatial features of 2 mm, although the spatial resolution of the detector is limited only by the pixel size and pinhole magnification factor. These characteristics are superior to alternative detectors currently in use in clinical SPECT systems. When imaging multiple radioisotopes simultaneously, we show that there is very little cross-talk between adjacent photopeaks, leading to superior image contrast. The detector is also capable of resolving fluorescence x-rays from the radioactive source, which could be used to improve image count statistics or derive information about the attenuation properties of the source. The performance presented here, and the ability to tile the detector modules to create a clinically useful field of view, makes this technology a strong candidate to be used in future solid-state SPECT cameras.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Development of a thick CdTe detector for BNCT-SPECT
    Murata, I.
    Mukai, T.
    Nakamura, S.
    Miyamarua, H.
    Kato, I.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (12) : 1706 - 1709
  • [2] Comparison between pixel array CdTe detector and NaI(Tl) detector for ultra-high resolution small animal SPECT imaging
    Park, S.
    Lee, C.
    Kim, H.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [3] Evaluation of a new small-pixel CdTe spectroscopic detector in dual-tracer SPECT brain imaging
    Scuffham, James W.
    Wilson, Matthew D.
    Pani, Silvia
    Duarte, Diana D.
    Veale, Matthew C.
    Bell, Stephen
    Seller, Paul
    Sellin, Paul J.
    Cernik, Robert J.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3115 - 3118
  • [4] The CdTe detector module and its imaging performance
    Issei Mori
    Takuzo Takayama
    Nobutoku Motomura
    Annals of Nuclear Medicine, 2001, 15 : 487 - 494
  • [5] The CdTe detector module and its imaging performance
    Mori, I
    Takayama, T
    Motomura, N
    ANNALS OF NUCLEAR MEDICINE, 2001, 15 (06) : 487 - 494
  • [6] Evaluation of Timepix3 based CdTe photon counting detector for fully spectroscopic small animal SPECT imaging
    Trojanova, E.
    Jakubek, J.
    Turecek, D.
    Sykora, V.
    Francova, P.
    Kolarova, V.
    Sefc, L.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [7] SWIR Hyperspectral Imaging Detector for Surface Residues
    Nelson, Matthew P.
    Mangold, Paul
    Gomer, Nathaniel
    Klueva, Oksana
    Treado, Patrick
    CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING XIV, 2013, 8710
  • [8] SPECT imaging with a semiconductor detector and a diverging collimator
    Fukizawa, Mizuho
    Ogawa, Koichi
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 836 - 839
  • [9] CdTe hybrid pixel detector for imaging with thermal neutrons
    Jakubek, J
    Mettivier, G
    Montesi, MC
    Pospisil, S
    Russo, P
    Vacik, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01): : 238 - 241
  • [10] Development of a CdTe thermal neutron detector for neutron imaging
    Miyake, Aki
    Nishioka, Takahiro
    Singh, Shailendra
    Morii, Hisashi
    Mimura, Hidenori
    Aoki, Toru
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 677 : 41 - 44