Time- and Temperature-Dependent Stability of Growth Factor Peptides in Human Autologous Serum Eye Drops

被引:45
作者
Bradley, Jay C. [2 ]
Simoni, Jan [3 ]
Bradley, Rachael H. [2 ]
McCartney, David L. [4 ]
Brown, Sandra M. [1 ]
机构
[1] Cabarrus Eye Inst, Concord, NC 28025 USA
[2] Univ Calif Davis, Dept Ophthalmol & Visual Sci, Sacramento, CA 95817 USA
[3] Texas Tech Univ, Hlth Sci Ctr, Dept Surg, Lubbock, TX 79430 USA
[4] Texas Tech Univ, Hlth Sci Ctr, Dept Ophthalmol & Visual Sci, Lubbock, TX 79430 USA
关键词
autologous serum; neurotrophic keratopathy; growth factor peptides; DRY EYE; MAINTENANCE; HEMOGLOBIN;
D O I
10.1097/ICO.0b013e318186321e
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purposes: To develop a step-by-step production method for human autologous serum (AS) eye drops that was broadly compliant with US Food and Drug Administration requirements for reinjection of processed biological substances. To determine optimum storage conditions for AS eye drops by measuring the concentration of growth factor peptides (GFP) as a Function of storage temperature and storage duration. Methods: AS derived front the blood of 3 healthy male volunteers was produced using a closed, vacuum-driven, cascade-filtration system under sterile, low-pyrogen conditions. In-process controls included methods for monitoring protein electrophoretic mobility and degradation rate and the content of free hemoglobin and endotoxin. Stability of transforming growth factor beta(1), substance P, nerve growth factor. calcitonin gene-related peptide, insulin-like growth factor 1. and epidermal growth factor was evaluated at -15 degrees C, +4 degrees C +25 degrees C +37 degrees C, and +42 degrees C at different time intervals (hours to weeks). The main Outcome measures were the concentrations of GFP endotoxin. and lipid peroxidation by-products (a proxy Measure for protein degradation) in dilute AS. Results: The stability of GFP varies: transforming growth factor beta(1), nerve growth factor, epidermal growth factor. and insulin-like growth factor 1 were more temperature and time resistant, but substance P and calcitonin gene-related peptide significantly degraded at +4 degrees C in 24 hours. Endotoxin and lipid peroxidation by-products were lot significantly increased by processing. Conclusions: This pilot study developed a closed, cascade-filtration system that was an effective method for the production of high-quality, low-pyrogen AS. The processing method broadly complied with Food and Drug Administration requirements for reinjection of biological Substances. Variable GFP stability was observed at +4 degrees C and above. For clinical use. AS should be packaged in daily-use containers, which should be stored frozen; the container in active use should be refrigerated between doses.
引用
收藏
页码:200 / 205
页数:6
相关论文
共 14 条
  • [11] Transplantation of autologous serum-derived cultivated corneal epithelial equivalents for the treatment of severe ocular surface disease
    Nakamura, Takahiro
    Inatomi, Tsutomu
    Sotozono, Chic
    Ang, Leonard P. K.
    Koizumi, Noriko
    Yokoi, Norihiko
    Kinoshita, Shigeru
    [J]. OPHTHALMOLOGY, 2006, 113 (10) : 1765 - 1772
  • [12] PROTECTIVE EFFECT OF SELENIUM ON HEMOGLOBIN MEDIATED LIPID-PEROXIDATION IN-VIVO
    SIMONI, J
    SIMONI, G
    GARCIA, EL
    PRIEN, SD
    TRAN, RM
    FEOLA, M
    SHIRES, GT
    [J]. ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 1995, 23 (04): : 469 - 486
  • [13] Treatment of dry eye by autologous serum application in Sjogren's syndrome
    Tsubota, K
    Goto, E
    Fujita, H
    Ono, M
    Inoue, H
    Saito, I
    Shimmura, S
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1999, 83 (04) : 390 - 395
  • [14] Comparison of autologous serum and umbilical cord serum eye drops for dry eye syndrome
    Yoon, Kyung-Chul
    Heo, Hwan
    Im, Seong-Kyu
    You, In-Cheon
    Kim, Yoon-Ha
    Park, Yeoung-Geol
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (01) : 86 - 92