A study on the maximum temperature of ceiling jet induced by rectangular source fires in a tunnel using ceiling smoke extraction

被引:181
作者
Tang, Fei [1 ]
Cao, Zhilei [1 ]
Palacios, Adriana [2 ]
Wang, Qiang [1 ]
机构
[1] Hefei Univ Technol, Sch Automot & Transportat Engn, Hefei, Anhui, Peoples R China
[2] Fdn Univ Amer, Dept Chem Food & Environm Engn, Puebla 72810, Mexico
基金
中国博士后科学基金;
关键词
Smoke flow; Maximum temperature; Tunnel fires; Burner aspect ratio; Ceiling smoke extraction; LONGITUDINAL VENTILATED TUNNEL; LAYERING FLOW LENGTH; SUBWAY STATION; NATURAL VENTILATION; GAS TEMPERATURE; HEAT-SOURCE; AIR-FLOW; BENEATH; CHANNEL; PROFILE;
D O I
10.1016/j.ijthermalsci.2018.02.001
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study analyzes the physics characteristics of the flame plume temperature, induced by a ceiling jet and their coupling with an extraction flow. As it is knows, the maximum increase in the temperature of a ceiling jet is a key parameter for tunnel fire safety. The ceiling maximum temperature has been analyzed and its evolution model has also been correlated in the past. However, those previous suggested correlations had considered the fire source shape is square or circular. Actually the van shape is rectangular, the corresponding fire source may be rectangular, which is necessary to extend it to other conditions of rectangular fire sources. It has also been noted that the smoke transport characteristics changed by the ceiling smoke extraction. The aim of this experimental work is to study the maximum increase in the temperature of a ceiling jet induced by rectangular-source fires with different burner aspect ratios (ranging from 1 to 8.2) in a tunnel, using a ceiling smoke extraction. The effects of different burner aspect ratios on the ceiling maximum smoke temperature increase were studied with and without a ceiling smoke extraction. The change of the burner aspect ratios, the ceiling mechanical extraction rate, and the heat release rate were also analyzed. The evolution characteristics of the ceiling maximum plume temperature rise, considering the different burner aspect ratios, with the change in the aspect ratios of burners without the ceiling extraction were firstly obtained. A new normalized equation of the ceiling maximum plume temperature, through the addition of an impact factor for the ceiling smoke extraction rate, of a ceiling jet induced by rectangular-source fires was established. The results indicated that the new global model can effectively predict experimental data.
引用
收藏
页码:329 / 334
页数:6
相关论文
共 45 条
[1]  
Alpert R.L., 1972, FIRE TECHNOL, V8, P181, DOI DOI 10.1007/BF02590543
[2]   Thermal buoyant smoke back-layering flow length in a longitudinal ventilated tunnel with ceiling extraction at difference distance from heat source [J].
Chen, L. F. ;
Hu, L. H. ;
Zhang, X. L. ;
Zhang, X. Z. ;
Zhang, X. C. ;
Yang, L. Z. .
APPLIED THERMAL ENGINEERING, 2015, 78 :129-135
[3]  
Dix A., 2010, P 4 INT S TUNN SAF S, P69
[4]   Smoke movement characteristics under stack effect in a mine laneway fire [J].
Fan, Chuan Gang ;
Li, Au Yan ;
Mu, Yan ;
Guo, Fang Yi ;
Ji, Jie .
APPLIED THERMAL ENGINEERING, 2017, 110 :70-79
[5]   Optical thickness of emissivity for pool fire radiation [J].
Fang, Jun ;
Wang, Jingwu ;
Tu, Ran ;
Shang, Rui ;
Zhang, Yong-ming ;
Wang, Jin-jun .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2018, 124 :338-343
[6]   Fire-induced smoke control via hybrid ventilation in a huge transit terminal subway station [J].
Gao, Ran ;
Li, Angui ;
Hao, Xinpeng ;
Lei, Wenjun ;
Zhao, Yujiao ;
Deng, Baoshun .
ENERGY AND BUILDINGS, 2012, 45 :280-289
[7]   Theoretical and experimental study on longitudinal smoke temperature distribution in tunnel fires [J].
Gong, Liang ;
Jiang, Lin ;
Li, Shuoyu ;
Shen, Na ;
Zhang, Yuchun ;
Sun, Jinhua .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2016, 102 :319-328
[8]   A Thin Skin Calorimeter (TSC) for quantifying irradiation during large-scale fire testing [J].
Hidalgo, Juan P. ;
Maluk, Cristian ;
Cowlard, Adam ;
Abecassis-Empis, Cecilia ;
Krajcovic, Michal ;
Torero, Jose L. .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2017, 112 :383-394
[9]   On the maximum smoke temperature under the ceiling in tunnel fires [J].
Hu, L. H. ;
Huo, R. ;
Peng, W. ;
Chow, W. K. ;
Yang, R. X. .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2006, 21 (06) :650-655
[10]   A global model on temperature profile of buoyant ceiling gas flow in a channel with combining mass and heat loss due to ceiling extraction and longitudinal forced air flow [J].
Hu, L. H. ;
Chen, L. F. ;
Tang, W. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 79 :885-892