Mobile EEG in epilepsy

被引:67
作者
Askamp, Jessica [1 ]
van Putten, Michel J. A. M. [1 ,2 ]
机构
[1] Univ Twente, Dept Clin Neurophysiol, MIRA Inst Biomed Engn & Tech Med, NL-7500 AE Enschede, Netherlands
[2] Med Spectrum Twente, Dept Clin Neurophysiol, Enschede, Netherlands
关键词
Mobile EEG; Home EEG; Epilepsy; Neurologists' opinions; EEG devices; Computer assisted reviewing; Patient satisfaction; TEMPORAL-LOBE EPILEPSY; INPATIENT VIDEO-EEG; LONG-TERM EEG; AMBULATORY EEG; PRESURGICAL EVALUATION; OUTPATIENT; SEIZURE; ELECTRODE; DATABASE; SPIKES;
D O I
10.1016/j.ijpsycho.2013.09.002
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
The sensitivity of routine EEG recordings for interictal epileptiform discharges in epilepsy is limited. In some patients, inpatient video-EEG may be performed to increase the likelihood of finding abnormalities. Although many agree that home EEG recordings may provide a cost-effective alternative to these recordings, their use is still not introduced everywhere. We surveyed Dutch neurologists and patients and evaluated a novel mobile EEG device (Mobita, TMSi). Key specifications were compared with three other current mobile EEG devices. We shortly discuss algorithms to assist in the review process. Thirty percent (33 out of 109) of Dutch neurologists reported that home EEG recordings are used in their hospital. The majority of neurologists think that mobile EEG can have additional value in investigation of unclear paroxysms, but not in the initial diagnosis after a first seizure. Poor electrode contacts and signal quality, limited recording time and absence of software for reliable and effective assistance in the interpretation of EEGs have been important constraints for usage, but in recent devices discussed here, many of these problems have been solved. The majority of our patients were satisfied with the home EEG procedure and did not think that our EEG device was uncomfortable to wear, but they did feel uneasy wearing it in public. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:30 / 35
页数:6
相关论文
共 29 条
[1]   Diagnostic decision-making after a first and recurrent seizure in adults [J].
Askamp, Jessica ;
van Putten, Michel J. A. M. .
SEIZURE-EUROPEAN JOURNAL OF EPILEPSY, 2013, 22 (07) :507-511
[2]   Wearable EEG: what is it, why is it needed and what does it entail? [J].
Casson, Alexander J. ;
Smith, Shelagh ;
Duncan, John S. ;
Rodriguez-Villegas, Esther .
2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, :5867-+
[3]   Outpatient EEG monitoring in the presurgical evaluation of patients with refractory temporal lobe epilepsy [J].
Chang, BS ;
Ives, JR ;
Schomer, DL ;
Drislane, FW .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2002, 19 (02) :152-156
[4]   Automated quantification of spikes [J].
Chavakula, Vamsidhar ;
Sanchez Fernandez, Ivan ;
Peters, Jurriaan M. ;
Popli, Gautam ;
Bosl, William ;
Rakhade, Sanjay ;
Rotenberg, Alexander ;
Loddenkemper, Tobias .
EPILEPSY & BEHAVIOR, 2013, 26 (02) :143-152
[5]   Ambulatory EEG: a cost-effective alternative to inpatient video-EEG in adult patients [J].
Dash, Dianne ;
Hernandez-Ronquillo, Lizbeth ;
Moien-Afshari, Farzad ;
Tellez-Zenteno, Jose F. .
EPILEPTIC DISORDERS, 2012, 14 (03) :290-297
[6]  
DOPPELBAUER A, 1993, ACTA NEUROL SCAND, V87, P345
[7]  
EBERSOLE JS, 1987, YALE J BIOL MED, V60, P85
[8]   The utility of prolonged outpatient ambulatory EEG [J].
Faulkner, Howard J. ;
Arima, Hisatomi ;
Mohamed, Armin .
SEIZURE-EUROPEAN JOURNAL OF EPILEPSY, 2012, 21 (07) :491-495
[9]   Scalp electrode impedance, infection risk, and EEG data quality [J].
Ferree, TC ;
Luu, P ;
Russell, GS ;
Tucker, DM .
CLINICAL NEUROPHYSIOLOGY, 2001, 112 (03) :536-544
[10]   Long-term computer-assisted outpatient electroencephalogram monitoring in children and adolescents [J].
Foley, CM ;
Legido, A ;
Miles, DK ;
Chandler, DA ;
Grover, WD .
JOURNAL OF CHILD NEUROLOGY, 2000, 15 (01) :49-55