Dry Eye After LASIK with a Femtosecond Laser or a Mechanical Microkeratome

被引:42
作者
Sun, Chi-Chin [1 ,2 ]
Chang, Chao-Kai [3 ]
Ma, David Hui-Kang [2 ,4 ]
Lin, Yi-Fang [1 ]
Chen, Kuan-Jen [4 ]
Sun, Ming-Hui [4 ]
Hsiao, Ching-Hsi [4 ]
Wu, Pei-Hsuan [5 ]
机构
[1] Chang Gung Mem Hosp, Dept Ophthalmol, Keelung, Taiwan
[2] Chang Gung Univ, Dept Chinese Med, Tao Yuan, Taiwan
[3] Nobel Laser Eye Ctr, Taipei, Taiwan
[4] Chang Gung Mem Hosp, Dept Ophthalmol, Tao Yuan, Taiwan
[5] Meiho Inst Technol, Dept Beauty Sci, Pingtung, Taiwan
关键词
laser in situ keratomileusis; femtosecond laser; microkeratome; dry eye; corneal sensitivity; IN-SITU KERATOMILEUSIS; GOBLET CELL-DENSITY; CORNEAL SENSATION; HINGE POSITION; NEUROTROPHIC EPITHELIOPATHY; OCULAR SURFACE; MYOPIC LASIK; FLAP CREATION; TEAR FILM; SENSITIVITY;
D O I
10.1097/OPX.0b013e31829d9905
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. Dry eye is the most common complication after LASIK procedure and is associated with corneal denervation. We conducted the study to compare dry eye parameters and corneal sensitivity (CS) after laser in situ keratomileusis (LASIK) with a femtosecond laser (FS) or microkeratome (MK). Methods. In this prospective, nonrandomized, comparative study, 87 consecutive patients with myopia were assigned to receive either LASIK surgery with an FS (n = 44) or MK-assisted LASIK surgery (n = 43). The groups were age and sex matched. Corneal sensitivity, Schirmer testing, tear breakup time (TBUT), conjunctival and corneal stainings, and a subjective questionnaire (Ocular Surface Disease Index [OSDI]) were evaluated preoperatively, at 1 week, and at 1, 3, and 6 months postoperatively. Results. Preoperative spherical equivalent and sphere, calculated ablation depth, and suction time differed significantly between the two groups (p < 0.01, all comparisons). Postoperatively, CS decreased in both groups and gradually recovered. Schirmer test values were not significantly different throughout the postoperative time points between the groups. Laser in situ keratomileusis-induced corneal epitheliopathy was also increased after operation in both groups. However, there was no significant difference between the groups in corneal and conjunctival staining scores. The OSDI scores were increased postoperatively in both groups. After adjustment for the calculated ablation depth, TBUT was the only parameter that was statistically higher in the FS group than in the MK group (p = 0.03). Conclusions. Both FS- and MK-assisted LASIK reduced CS and TBUT and increased corneal staining and OSDI scores. However, TBUT was significantly higher in the FS group than in the MK group after operation.
引用
收藏
页码:1048 / 1056
页数:9
相关论文
共 33 条
[1]   Chronic dry eye and regression after laser in situ keratomileusis for myopia [J].
Albietz, JM ;
Lenton, LM ;
McLennan, SG .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (03) :675-684
[2]   Effect of laser in situ keratomileusis for hyperopia on tear film and ocular surface [J].
Albietz, JM ;
Lenton, LM ;
McLennan, SG .
JOURNAL OF REFRACTIVE SURGERY, 2002, 18 (02) :113-123
[3]   LASIK-associated dry eye and neurotrophic epitheliopathy: Pathophysiology and strategies for prevention and treatment [J].
Ambrosio, Renato, Jr. ;
Tervo, Timo ;
Wilson, Steven E. .
JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (04) :396-407
[4]   Effects of laser in situ keratomileusis on tear production, clearance, and the ocular surface [J].
Battat, L ;
Macri, A ;
Dursun, D ;
Pflugfelder, SC .
OPHTHALMOLOGY, 2001, 108 (07) :1230-1235
[5]   Flap dimensions created with the IntraLase FS laser [J].
Binder, PS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (01) :26-32
[6]   The incidence and risk factors for developing dry eye after myopic LASIK [J].
De Paiva, CS ;
Chen, Z ;
Koch, DD ;
Hamill, MB ;
Manuel, FK ;
Hassan, SS ;
Wilhelmus, KR ;
Pflugfelder, SC .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (03) :438-445
[7]   Comparison of photorefractive keratectomy with excimer laser in situ keratomileusis in correcting low myopia (from -2.00 to -5.50 diopters) - A randomized study [J].
El Danasoury, MA ;
El Maghraby, A ;
Klyce, SD ;
Mehrez, K .
OPHTHALMOLOGY, 1999, 106 (02) :411-420
[8]  
Gipson IK, 2007, OCUL SURF, V5, P179
[9]   Porcine model to compare real-time intraocular pressure during LASIK with a mechanical microkeratome and femtosecond laser [J].
Hernandez-Verdejo, Jose L. ;
Teus, Miguel A. ;
Roman, Jose M. ;
Bolivar, Gema .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (01) :68-72
[10]   Effect of Hinge Position on Corneal Sensation and Dry Eye Parameters After Femtosecond Laser-assisted LASIK [J].
Huang, Jerry Chien-Chieh ;
Sun, Chi-Chin ;
Chang, Chao-Kay ;
Ma, David Hui-Kang ;
Lin, Yi-Fang .
JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (09) :625-631