Characterization of implant device materials using size-exclusion chromatography with mass spectrometry and with triple detection

被引:12
作者
Liu, XM [1 ]
Maziarz, EP [1 ]
Heiler, DJ [1 ]
机构
[1] Bausch & Lomb Inc, Res Dev & Engn, Rochester, NY 14601 USA
关键词
implant device materials; molecular mass distributions; mass spectrometry; triple detection; polymers; poly(dimethyl)siloxane;
D O I
10.1016/j.chroma.2004.02.031
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A more complete understanding of the raw materials used for making implant device materials becomes increasingly important in the medical device industry. Often such detailed information requires utilization of a combination of analytical techniques. In this work, we characterize a poly(dimethyl siloxane) (PDMS) material using on-line size exclusion chromatography (SEC) with electrospray ionization (ESI) and matrix assisted laser desorption ionization (MALDI) mass spectrometry (MS) techniques. Here, we obtain detailed molecular compositional information such as repeat units, end group chemistry, and identification of impurities in both the high and low mass range. SEC with light scattering, viscosity, and refractive index detection (triple detection) is used to obtain information on a small quantity of high mass impurity that was undetected by both SEC-ESI and MALDI MS techniques. SEC with triple detection measures absolute molecular weights and molecular weight distributions. We compare average molecular weight values of the implantable device polymer obtained by SEC with triple detection, SEC-ESI, and SEC-MALDI MS techniques. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:125 / 131
页数:7
相关论文
共 50 条
  • [31] CHARACTERIZATION OF POLYBUTYLACRYLATE-B-POLYVINYLPYRIDINE BLOCK COPOLYMERS BY SIZE-EXCLUSION CHROMATOGRAPHY AND DUAL REFRACTIVE INDEX/UV-DETECTION
    Keller, Nicolas
    Auschra, Clemens
    Knischka, Ralf
    Steiner, Werner
    Scherer, Gerd
    Heinzmann, Gerhard
    Tartsch, Bernd
    Rissler, Klaus
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2010, 33 (17) : 1587 - 1600
  • [32] Iterative size-exclusion chromatography coupled with liquid chromatographic mass spectrometry to enrich and identify tight-binding ligands from complex mixtures
    Davis, RG
    Anderegg, RJ
    Blanchard, SG
    [J]. TETRAHEDRON, 1999, 55 (39) : 11653 - 11667
  • [33] Exploration of cardanol-based phenolated and epoxidized resins by size exclusion chromatography and MALDI mass spectrometry
    Fouquet, Thierry
    Puchot, Laura
    Verge, Pierre
    Bomfim, Joao A. S.
    Ruch, David
    [J]. ANALYTICA CHIMICA ACTA, 2014, 843 : 46 - 58
  • [34] Characterization of U-matic videotape deterioration by size exclusion chromatography and pyrolysis gas chromatography/mass spectrometry and the role of adipic acid
    Thiebaut, Benoit
    Vilmont, Leon-Bavi
    Lavedrine, Bertrand
    [J]. JOURNAL OF CULTURAL HERITAGE, 2009, 10 (02) : 183 - 197
  • [35] Quantitative assessment of polymer molecular shape based on changes in the slope of the Mark-Houwink plot derived from size-exclusion chromatography with triple detection
    Bos, Tijmen S.
    Philipsen, Harry J. A.
    Staal, Bastiaan B. P.
    Purmova, Jindra
    Beerends, Rene J. L.
    Buijtenhuijs, Ab
    Karlson, Leif
    Schoenmakers, Peter J.
    Somsen, Govert W.
    [J]. JOURNAL OF APPLIED POLYMER SCIENCE, 2024, 141 (09)
  • [36] Modeling study of long-term stability of the monoclonal antibody infliximab and biosimilars using liquid-chromatography-tandem mass spectrometry and size-exclusion chromatography-multi-angle light scattering
    Legrand, Pauline
    Dufay, Sophie
    Mignet, Nathalie
    Houze, Pascal
    Gahoual, Rabah
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (01) : 179 - 192
  • [37] Modeling study of long-term stability of the monoclonal antibody infliximab and biosimilars using liquid-chromatography–tandem mass spectrometry and size-exclusion chromatography–multi-angle light scattering
    Pauline Legrand
    Sophie Dufaÿ
    Nathalie Mignet
    Pascal Houzé
    Rabah Gahoual
    [J]. Analytical and Bioanalytical Chemistry, 2023, 415 : 179 - 192
  • [38] Mark-Houwink Parameters for the Universal Calibration of Acrylate, Methacrylate and Vinyl Acetate Polymers Determined by Online Size-Exclusion Chromatography-Mass Spectrometry
    Gruendling, Till
    Junkers, Thomas
    Guilhaus, Michael
    Barner-Kowollik, Christopher
    [J]. MACROMOLECULAR CHEMISTRY AND PHYSICS, 2010, 211 (05) : 520 - 528
  • [39] Comparison of electrospray ionisation mass spectrometry with matrix-assisted laser desorption ionisation mass spectrometry and size exclusion chromatography for the characterisation of polyester resins
    Hunt, SM
    Sheil, MM
    [J]. EUROPEAN MASS SPECTROMETRY, 1998, 4 (06): : 475 - 486
  • [40] Modeling of the molar mass distribution of six-arm star-branched poly-ε-caprolactam using size-exclusion chromatography
    Versluis, C
    Hillegers, T
    Geladé, E
    Nijenhuis, A
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 1008 (02) : 157 - 165