Study of heavy metals in Madeira wine by total reflection x-ray fluorescence analysis

被引:0
|
作者
Carvalho, ML [1 ]
Barreiros, MA [1 ]
Costa, MM [1 ]
Ramos, MT [1 ]
Marques, MI [1 ]
机构
[1] INST TECNOL AMBIENTAIS,P-1699 LISBON,PORTUGAL
关键词
D O I
10.1002/(SICI)1097-4539(199601)25:1<29::AID-XRS134>3.0.CO;2-Z
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The suitability and high sensitivity of total-reflection x-ray fluorescence analysis (TXRF) were used for multielement analysis of several species of Madeira wine taken directly from the usual glass Bottles. In addition, the uptake of lead by Madeira wine kept in a crystal vessel (30% lead) as a function of time was also studied. The detection limits were in the range 0.001-0.10 mg l(-1) and the precision was in the range 5-10%. The organic matrix of the wine was removed by wet digestion in nitric acid.
引用
收藏
页码:29 / 32
页数:4
相关论文
共 50 条
  • [41] Error factors in quantitative total reflection x-ray fluorescence analysis
    Mori, Y
    Uemura, K
    X-RAY SPECTROMETRY, 1999, 28 (06) : 421 - 426
  • [42] Total Reflection X-Ray Fluorescence Analysis of Solid Metallurgical Samples
    P. Yu. Sharanov
    N. V. Alov
    Journal of Analytical Chemistry, 2018, 73 : 1085 - 1092
  • [43] Analysis of coke beverages by total-reflection X-ray fluorescence
    Fernandez-Ruiz, Ramon
    von Bohlen, Alex
    Friedrich K, E. Josue
    Redrejo, M. J.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 145 : 99 - 106
  • [44] Nonaqueous suspensions in total reflection X-ray fluorescence analysis of solids
    P. Yu. Sharanov
    N. V. Alov
    Yu. A. Zolotov
    Doklady Chemistry, 2016, 467 : 91 - 93
  • [45] Direct analysis of biological samples by total reflection X-ray fluorescence
    Marcó, LAP
    Hernández-Caraballo, EA
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (08) : 1077 - 1090
  • [46] Optimisation of total-reflection X-ray fluorescence for aerosol analysis
    Injuk, J
    VanGrieken, R
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (14) : 1787 - 1803
  • [47] Total Reflection X-Ray Fluorescence Analysis of Natural and Drinking Waters
    K. V. Oskolok
    O. V. Monogarova
    N. V. Alov
    Journal of Analytical Chemistry, 2018, 73 : 1093 - 1097
  • [48] Total Reflection X-Ray Fluorescence Analysis of Natural and Drinking Waters
    Oskolok, K. V.
    Monogarova, O. V.
    Alov, N. V.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 73 (11) : 1093 - 1097
  • [49] Error Factors in Quantitative Total Reflection X-Ray Fluorescence Analysis
    Adv. Technol. Research Laboratories, Nippon Steel Corporation, C/o NSC Electron Corporation, 3434 Shimata, Hikari, Yamaguchi 743-0063, Japan
    X-Ray Spectrom., 6 (421-426):
  • [50] Total Reflection X-Ray Fluorescence Analysis of Solid Metallurgical Samples
    Sharanov, P. Yu.
    Alov, N. V.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 73 (11) : 1085 - 1092