Measurement of absolute K X-ray emission intensities in the decay of 103mRh

被引:5
|
作者
Riffaud, J. [1 ]
Cassette, P. [1 ]
Lacour, D. [1 ]
Lourenco, V. [1 ]
Tartes, I. [1 ]
Kellett, M. A. [1 ]
Corbel, M. [1 ]
Lepy, M. -C. [1 ]
Domergue, C. [2 ]
Destouches, C. [2 ]
Carcreff, H. [3 ]
Vigneau, O. [4 ]
机构
[1] CEA Saclay, CEA, LIST, LNE,LNHB, F-91191 Gif Sur Yvette, France
[2] CEA, DEN, DER, LDCI, F-13108 St Paul Les Durance, France
[3] CEA Saclay, CEA, DEN, DRSN,LSPI, F-91191 Gif Sur Yvette, France
[4] CEA, DEN, DEC, LARC, F-13108 St Paul Les Durance, France
关键词
Rh-103m; TDCR method; X-ray spectrometry; Photon emission intensity; Reactor dosimetry;
D O I
10.1016/j.apradiso.2017.10.003
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A new experiment was designed to measure the photon emission intensities in the decay of Rh-103m. The rhodium samples were activated in the ISIS experimental nuclear reactor at CEA Saclay. The procedure includes an absolute activity measurement by liquid scintillation counting using the Triple-to-Double Coincidence Ratio method, followed by X-ray spectrometry using a high-purity germanium detector to determine the photon emission intensities. The new result I-x = 0.0825 (17)) is derived with a significant reduction of the uncertainty.
引用
收藏
页码:399 / 405
页数:7
相关论文
共 50 条
  • [1] MEASUREMENT OF K X-RAY EMISSION IN DECAY OF 103MRH
    BRESESTI, AM
    BRESESTI, M
    NEUMANN, H
    JOURNAL OF INORGANIC & NUCLEAR CHEMISTRY, 1967, 29 (01): : 15 - &
  • [2] Measurement of the absolute gamma-ray emission intensities from the decay of 103Pd
    Riffaud, J.
    Lepy, M-C
    Cassette, P.
    Corbel, M.
    Kellett, M. A.
    Lourenco, V
    APPLIED RADIATION AND ISOTOPES, 2021, 167
  • [3] A METHOD FOR CALIBRATION OF 103MRH AND ABSOLUTE CROSS SECTION FOR REACTION 103RH(N,N') 103MRH WITH 14.2 MEV NEUTRONS
    NAGEL, W
    ATEN, AHW
    JOURNAL OF NUCLEAR ENERGY PARTS A AND B-REACTOR SCIENCE AND TECHNOLOGY, 1966, 20 (6PA-): : 475 - &
  • [4] MEASUREMENT AND CALCULATION OF ABSOLUTE X-RAY INTENSITIES
    BROWN, DB
    GILFRICH, JV
    JOURNAL OF APPLIED PHYSICS, 1971, 42 (10) : 4044 - +
  • [5] Measurement of absolute x-ray intensities and absolute sensitivity of x-ray film with a Geiger-Muller counter
    Locher, GL
    LeGalley, DP
    PHYSICAL REVIEW, 1934, 46 (12): : 1047 - 1051
  • [6] Improvement of 93mNb and 103mRh activity measurement methodology for reactor dosimetry
    Riffaud, J.
    Lepy, M. -C.
    Domergue, C.
    Philibert, H.
    Destouches, C.
    Thiollay, N.
    Girard, J. M.
    ICRS-13 & RPSD-2016, 13TH INTERNATIONAL CONFERENCE ON RADIATION SHIELDING & 19TH TOPICAL MEETING OF THE RADIATION PROTECTION AND SHIELDING DIVISION OF THE AMERICAN NUCLEAR SOCIETY - 2016, 2017, 153
  • [7] K AND L X-RAY INTENSITIES IN CESIUM-131 DECAY
    FINK, RW
    ROBINSON, BL
    PHYSICAL REVIEW, 1955, 98 (05): : 1293 - 1296
  • [8] Measurement of the absolute gamma-ray emission intensities from the decay of 147Nd
    Kellett, M. A.
    Vio, L.
    Bobin, C.
    Brondeau, L.
    Cardot-Martin, M.
    Isnard, H.
    Lacour, D.
    Lepy, M-C
    Lourenco, V
    Marie, M.
    Thiam, C.
    APPLIED RADIATION AND ISOTOPES, 2020, 166 (166)
  • [9] The measurement in absolute units of the intensities of X-ray reflections from crystalline powders
    Brindley, GW
    PROCEEDINGS OF THE PHYSICAL SOCIETY, 1938, 50 : 17 - 29
  • [10] EFFECT OF EXCITATION ON X-RAY EMISSION INTENSITIES
    BERNSTEIN, F
    ISA TRANSACTIONS, 1967, 6 (02) : 99 - +