Effect of total cementitious content on shear strength of high-volume fly ash concrete beams

被引:28
作者
Arezoumandi, Mahdi [1 ]
Volz, Jeffery S. [1 ]
Ortega, Carlos A. [1 ]
Myers, John J. [1 ]
机构
[1] Missouri Univ Sci & Technol, Dept Civil Architectural & Environm Engn, Rolla, MO 65409 USA
关键词
High-volume fly ash concrete; Conventional concrete; Shear strength; Experimental study;
D O I
10.1016/j.matdes.2012.10.031
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The production of portland cement - the key ingredient in concrete - generates a significant amount of carbon dioxide. However, due to its incredible versatility, availability, and relatively low cost, concrete is the most consumed manmade material on the planet. One method of reducing concrete's contribution to greenhouse gas emissions is the use of fly ash to replace a significant amount of the cement. This paper compares two experimental studies that were conducted to investigate the shear strength of full-scale beams constructed with high-volume fly ash concrete (HVFAC) - concrete with at least 50% of the cement replaced with fly ash. The primary difference between the two studies involved the amount of cementitious material, with one mix having a relatively high total cementitious content (502 kg/m(3)) and the other mix having a relatively low total cementitious content (337 kg/m(3)). Both mixes utilized a 70% replacement of portland cement with a Class C fly ash. Each of these experimental programs consisted of eight beams (six without shear reinforcing and two with shear reinforcing in the form of stirrups) with three different longitudinal reinforcement ratios. The beams were tested under a simply supported four-point loading condition. The experimental shear strengths of the beams were compared with both the shear provisions of selected standards (US, Australia, Canada, Europe, and Japan) and a shear database of conventional concrete (CC) specimens. Furthermore, statistical data analyses (both parametric and nonparametric) were performed to evaluate whether or not there is any statistically significant difference between the shear strength of both mixes. Results of these statistical tests show there is no significant difference between the shear strength of these two HVFAC mixes for the beams tested in this investigation. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:301 / 309
页数:9
相关论文
共 32 条
[1]  
ACI 318/ 318R, 2008, 31808318R08 ACI, P155
[2]  
ACI Committee 232, 2003, 2322003 ACI COMM
[3]  
ALONZO O, 1993, ACI MATER J, V90, P272
[4]  
[Anonymous], P 14 WORLD C EARTHQ
[5]  
[Anonymous], 2004, CSA A23.3, V2004th, P53
[6]  
[Anonymous], 1974, ACI SP
[7]  
[Anonymous], 2005, Design of concrete structures. Part 1: General rules and rules for buildings, P84
[8]  
[Anonymous], 2010, AASHTO LRFD bridge design specifications, V4th, P5
[9]  
[Anonymous], 2012, Minerals Yearbook, Cement, P38
[10]  
[Anonymous], 3600 AS