VNIIOFI secondary-standard sources and detectors of vacuum-ultraviolet and ultraviolet radiation

被引:2
作者
Anevsky, SI [1 ]
Vernyi, AE [1 ]
Korneev, VV [1 ]
Minaeva, OA [1 ]
Morozov, OY [1 ]
Khromchenko, VB [1 ]
机构
[1] IVK JOINT STOCK CO,MOSCOW 129090,RUSSIA
关键词
D O I
10.1088/0026-1394/32/6/40
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The stability and reproducibility of secondary-standard sources and detectors are the main problems and the fundamental trouble of spectroradiometry in the ultraviolet spectral range. The high accuracy of the spectroradiometric unit for primary standards based on synchrotron radiation sources is lost by transferring that unit to unstable or irreproducible secondary standards. The best secondary-standard sources and detectors for units of spectral radiance, irradiance, radiant power and flux for the wavelength range 30 nm to 400 nm are described. Integral radiometers for different applications are presented.
引用
收藏
页码:597 / 600
页数:4
相关论文
共 9 条
[1]   THE USE OF SYNCHROTRON RADIATION OF ELECTRON CIRCLES IN APPLICATIONS [J].
ANEVSKY, SI ;
VERNYI, AY ;
PANASYUK, VS ;
SAPRITSKY, VI .
PHYSICA SCRIPTA, 1987, 35 (05) :623-627
[2]   IMPROVEMENTS OF THE TROLL-2 SYNCHROTRON AND NEW DEVELOPMENTS [J].
ANEVSKY, SI ;
VERNYI, AE ;
PANASYUK, VS ;
KHROMCHENKO, VB .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 308 (1-2) :35-38
[3]   USE OF SYNCHROTRON RADIATION FOR CALIBRATION OF A WORKING MEASURING INSTRUMENT BASED ON PLASMA-FOCUS [J].
ANEVSKY, SI ;
VERNYI, AE ;
KOZLOV, NP ;
KONEV, IV ;
MALASCHENKO, VA ;
MOROZOV, OY ;
TSYGANKOV, PA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 282 (2-3) :714-715
[4]   REALIZATION OF A SPECTRAL RADIANCE SCALE IN THE 40-250-NM SPECTRAL REGION-BASED ON A TROLL-TYPE SYNCHROTRON [J].
ANEVSKY, SI ;
VERNYI, AE ;
KHROMCHENKO, VB ;
PANASYUK, VS ;
SAPRITSKY, VI .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 347 (1-3) :573-576
[5]   LABORATORY SOURCE OF SYNCHROTRON RADIATION - TROLL-2 [J].
ANEVSKY, SI ;
VERNYI, AE ;
PANASJUK, VS ;
KHROMCHENKO, VB .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 261 (1-2) :56-57
[6]   ELECTRON STORAGE RING BESSY AS A SOURCE OF CALCULABLE SPECTRAL PHOTON FLUX IN THE X-RAY REGION [J].
ARNOLD, D ;
ULM, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :1539-1542
[7]  
KEY PJ, 1977, APPL OPTICS, V9, P2477
[8]  
KLOZE JZ, 1987, NBS SPEC PUBL, V2503
[9]   ABSOLUTE CALIBRATION OF LIGHT SOURCES IN VACUUM ULTRAVIOLET BY MEANS OF SYNCHROTRON RADIATION OF DESY [J].
PITZ, E .
APPLIED OPTICS, 1969, 8 (02) :255-&