A Fault-Tolerant Control Method of 12-Phase PMSM in FESS

被引:0
作者
Li, Wencan [1 ]
Lv, Jingliang [1 ]
Jiang, Xinjian [1 ]
Zhang, Xinzhen [2 ]
Sheng, Shuang [2 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, Beijing, Peoples R China
[2] Tsinghua Univ, Sichuan Energy Internet Res Inst, Chengdu, Peoples R China
来源
2019 IEEE 10TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG 2019) | 2019年
关键词
flywheel energy storage system (FESS); 12-phase PMSM; fault-tolerant control; one phase open-circuit; a compensation method;
D O I
10.1109/pedg.2019.8807479
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Multi-phase motors are applied in flywheel energy storage system (FESS) to improve the power level, and at the same time offer phase redundancy characteristics. This paper investigates the fault-tolerant control of 12-phase permanent magnetic synchronous motor (PMSM) with one phase open-circuit in FESS. The 12 phases have 4 sets of stator windings and each set is connected to one 3-phase converter. In case of one phase open-circuit, the converter containing the fault-phase is not cut off but operates as a single-phase driver while the left three still operate as 3-phase drivers. Thus the output capability of the converter containing fault-phase is utilized. Moreover, a compensation method is developed to solve the power fluctuation caused by the single-phase motor. Consequently, the fault-tolerant control of FESS is achieved and the power rating is not reduced. The model for FESS based on 12-phase PMSM is developed in Matlab/Simulink, and the results validate the effectiveness of the proposed fault-tolerant control method.
引用
收藏
页码:269 / 273
页数:5
相关论文
共 8 条
[1]  
Bhurse Sneha S., 2018, 2018 International Conference on Computation of Power, Energy, Information and Communication (ICCPEIC), P363, DOI 10.1109/ICCPEIC.2018.8525157
[2]  
Changpan Z., 2018, J ENG, V2018, P489
[3]   Fault-Tolerant Control of a Six-Phase Motor Drive System Using a Takagi-Sugeno-Kang Type Fuzzy Neural Network With Asymmetric Membership Function [J].
Lin, Faa-Jeng ;
Hung, Ying-Chih ;
Hwang, Jonq-Chin ;
Tsai, Meng-Ting .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (07) :3557-3572
[4]   Global Fault-Tolerant Control Technique for Multiphase Permanent-Magnet Machines [J].
Mohammadpour, Ali ;
Parsa, Leila .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2015, 51 (01) :178-186
[5]  
Qian YN, 2016, ASIA-PAC POWER ENERG, P2514, DOI 10.1109/APPEEC.2016.7779941
[6]   Control algorithms for a fault-tolerant PMSM drive [J].
Wallmark, Oskar ;
Harnefors, Lennart ;
Carlson, Ola .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (04) :1973-1980
[7]   Fault-Tolerant Control of Dual Three-Phase Permanent-Magnet Synchronous Machine Drives Under Open-Phase Faults [J].
Wang, Wei ;
Zhang, Jinghao ;
Cheng, Ming ;
Li, Shihua .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (03) :2052-2063
[8]  
[王永兴 Wang Yongxing], 2015, [电工技术学报, Transactions of China Electrotechnical Society], V30, P49