Voltammetry of the anticancer drug mitoxantrone and DNA

被引:0
作者
Erdem, A [1 ]
Özsöz, M [1 ]
机构
[1] Ege Univ, Dept Analyt Chem, Fac Pharm, TR-35100 Izmir, Turkey
关键词
mitoxantrone; biosensors; DNA; voltammetry; intercalation;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The interaction of mitoxantrone (MTX) with calf thymus double-stranded DNA (dsDNA) and calf thymus single-stranded DNA (ssDNA) was studied electrochemically by using differential pulse voltammetry (DPV) and cyclic voltammetry (CV) at a carbon paste electrode (CPE). The changes in the experimental parameters (the concentration of MTX, the concentration of DNA and the accumulation time of MTX) were studied by DPV; in addition, the detection limit and the reproducibility were determined. It was observed for the interaction of MTX with dsDNA and ssDNA that the signal of the bare electrode was higher than the signal of the dsDNA modified CPE. The signals in the cyclic voltammograms were found to be decreasing in the following order: bare CPE, ssDNA modified and dsDNA modified CPE.
引用
收藏
页码:469 / 475
页数:7
相关论文
共 30 条
  • [1] Voltammetric behaviour of mitoxantrone at a DNA-biosensor
    Brett, AMO
    Macedo, TRA
    Raimundo, D
    Marques, MH
    Serrano, SHP
    [J]. BIOSENSORS & BIOELECTRONICS, 1998, 13 (7-8) : 861 - 867
  • [2] Novel hybridization indicator methylene blue for the electrochemical detection of short DNA sequences related to the hepatitis B virus
    Erdem, A
    Kerman, K
    Meric, B
    Akarca, US
    Ozsoz, M
    [J]. ANALYTICA CHIMICA ACTA, 2000, 422 (02) : 139 - 149
  • [3] Erdem A, 1999, ELECTROANAL, V11, P586
  • [4] Erdem A, 1999, ELECTROANAL, V11, P1372, DOI 10.1002/(SICI)1521-4109(199912)11:18<1372::AID-ELAN1372>3.0.CO
  • [5] 2-4
  • [6] Determination of traces of RNA in submicrogram amounts of single- or double-stranded DNAs by means of nucleic acid-modified electrodes
    Fojta, M
    Doffkova, R
    Palecek, E
    [J]. ELECTROANALYSIS, 1996, 8 (05) : 420 - 426
  • [7] STRUCTURE AND DRUG-INTERACTIONS OF PARALLEL-STRANDED DNA STUDIED BY INFRARED-SPECTROSCOPY AND FLUORESCENCE
    FRITZSCHE, H
    AKHEBAT, A
    TAILLANDIER, E
    RIPPE, K
    JOVIN, TM
    [J]. NUCLEIC ACIDS RESEARCH, 1993, 21 (22) : 5085 - 5091
  • [8] Microfabricated disposable DNA sensor for detection of hepatitis B virus DNA
    Hashimoto, K
    Ito, K
    Ishimori, Y
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1998, 46 (03) : 220 - 225
  • [9] Quantitative analysis for solid-phase hybridization reaction and binding reaction of DNA binder to hybrids using a quartz crystal microbalance
    Ito, K
    Hashimoto, K
    Ishimori, Y
    [J]. ANALYTICA CHIMICA ACTA, 1996, 327 (01) : 29 - 35
  • [10] Single-base mismatch detection based on charge transduction through DNA
    Kelley, SO
    Boon, EM
    Barton, JK
    Jackson, NM
    Hill, MG
    [J]. NUCLEIC ACIDS RESEARCH, 1999, 27 (24) : 4830 - 4837