Agreement Between Autorefraction and Subjective Refraction in Keraring-Implanted Keratoconic Eyes

被引:1
作者
Al-Tuwairqi, Waleed S. [1 ]
Ogbuehi, Kelechi C. [2 ]
Razzouk, Haya [1 ]
Alanazi, Mana A. [3 ]
Osuagwu, Uchechukwu L. [4 ]
机构
[1] Elite Med & Surg Ctr, Refract Surg Unit, Riyadh, Saudi Arabia
[2] Univ Otago, Dunedin Sch Med, Dept Med, Dunedin, New Zealand
[3] King Saud Univ, Coll Appl Med Sci, Dept Optometry & Vis Sci, Riyadh, Saudi Arabia
[4] Queensland Univ Technol, Dept Optometry & Vis Sci, Chron Dis & Ageing, Inst Hlth & Biomed Innovat, Brisbane, Qld, Australia
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2017年 / 43卷 / 02期
关键词
Keraring; Subjective refraction; Autorefraction; Myopia; Keratoconus; NIPPON SRW-5000 AUTOREFRACTOR; INTRACORNEAL RING SEGMENTS; CLINICAL-EVALUATION; OCULAR ABERRATIONS; FEMTOSECOND LASER; REPEATABILITY; TOPOGRAPHY;
D O I
10.1097/ICL.0000000000000244
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives:To assess the agreement between subjective refraction and autorefraction and to explore the relationship between the magnitude of higher order aberration, and visual acuity and refraction, before and after keraring implantation.Methods:This prospective, randomized, interventional study enrolled 27 subjects (mean age 28.16.5 years) with keratoconus. Noncycloplegic refraction was performed subjectively by one clinician and with an autorefractor by another clinician, before and 6 months after surgery. The limit of agreement (LoA) between methods was assessed, and the relationships between the corrected distance visual acuity, logMAR on the one hand and refraction measurements and higher-order aberrations on the other, were examined.Results:The agreement in mean spherical equivalent refraction (MSER) between methods was good postoperatively but poor preoperatively. The autorefractor gave a more myopic refraction than subjective refraction preoperatively (-3.28 +/- 3.06 D; LoA -9.27 to +2.71 D, P<0.0001) and postoperatively (-0.63 +/- 1.64 D; LoA -3.85 to +2.58 D, P=0.055), and returned higher negative cylinders preoperatively (-1.10 +/- 1.17 D; LoA -3.40 to +1.19 D, P<0.0001) and postoperatively (-1.08 +/- 1.27 D; LoA -3.60 to +1.41 D, P<0.0001) in keratoconic eyes. The difference in MSER between methods was significantly related to the refractive error at both visits (P<0.05) and to the magnitude of higher-order aberrations in keratoconic eyes preoperatively (P<0.05). The logMAR visual acuity achieved subjectively worsened as the magnitude of higher-order aberrations increased preoperatively (P<0.001).Conclusions:The autorefractor returns values that are significantly more myopic in MSER and higher negative cylinders than subjective refraction, preoperatively, but the MSER was similar between devices postoperatively. The autorefactor seems a valid starting point for subjective refraction in keratoconic eyes treated with keraring, but the cylinder should be corrected by about +1 D. The instruments agree more in less myopic than high myopic eyes.
引用
收藏
页码:116 / 122
页数:7
相关论文
共 42 条
[1]   Intracorneal ring segments for keratoconus correction:: Long-term follow-up [J].
Alio, Jorge L. ;
Shabayek, Mohamed H. ;
Artola, Alberto .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (06) :978-985
[2]  
Alió JL, 2006, J REFRACT SURG, V22, P539
[3]   Aberrations of emmetropic subjects at different ages [J].
Atchison, David A. ;
Markwell, Emma L. .
VISION RESEARCH, 2008, 48 (21) :2224-2231
[4]   Peripheral Ocular Aberrations in Mild and Moderate Keratoconus [J].
Atchison, David A. ;
Mathur, Ankit ;
Read, Scott A. ;
Walker, Mitchell I. ;
Newman, Alexander R. ;
Tanos, Photios P. ;
McLennan, Roderick T. ;
Tran, Andrew H. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (12) :6850-6857
[5]   Repeatability of autorefraction and axial length measurements after laser in situ keratomileusis [J].
Bailey, MD ;
Twa, MD ;
Mitchell, GL ;
Dhaliwal, DK ;
Jones, LA ;
McMahon, TT .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (05) :1025-1034
[6]  
Bellows JG, 1970, U.S. Patent, Patent No. [3,524,702, 2524702]
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]  
Chat SWS, 2001, OPHTHAL PHYSL OPT, V21, P87, DOI 10.1016/S0275-5408(00)00048-X
[9]   Diagnostic accuracy and variability of autorefraction by the Tracey Visual Function Analyzer and the Shin-Nippon NVision-K 5001 in relation to subjective refraction [J].
Cleary, G. ;
Spalton, D. J. ;
Patel, P. M. ;
Lin, P. -F. ;
Marshall, J. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2009, 29 (02) :173-181
[10]   One-year results of intrastromal corneal ring segment implantation (KeraRing) using femtosecond laser in patients with keratoconus [J].
Coskunseven, Efekan ;
Kymionis, George D. ;
Tsiklis, Nikolaos S. ;
Atun, Serife ;
Arslan, Ebru ;
Jankov, Mirko R. ;
Pallikaris, Ioannis G. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (05) :775-779