Comparison of dynamic changes in aortic diameter during the cardiac cycle measured by computed tomography angiography and transthoracic echocardiography

被引:11
作者
Huang, Jian [1 ,2 ]
Wang, Yongsheng [1 ]
Lin, Lin [3 ]
Li, Zhibin [4 ]
Shan, Zhonggui [2 ]
Zheng, Shaoyi [1 ]
机构
[1] Southern Med Univ, Nanfang Hosp, Dept Cardiovasc Surg, Sch Clin Med 1, 1023 S Shatai Rd, Guangzhou 510515, Guangdong, Peoples R China
[2] Xiamen Univ, Affiliated Hosp 1, Dept Cardiovasc Surg, Xiamen, Peoples R China
[3] Xiamen Univ, Affiliated Hosp 1, Cent Lab, Xiamen, Peoples R China
[4] Xiamen Univ, Affiliated Hosp 1, Epidemiol Res Unit, Xiamen, Peoples R China
关键词
Aortic diameter; Transthoracic echocardiography; Computed tomography angiography; Intraoperative ultrasound; Dynamic change; ASSOCIATION; DISSECTION; SOCIETY; IMPACT;
D O I
10.1016/j.jvs.2018.07.083
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This study aimed to examine the relationship between dynamic changes in aortic diameter and corresponding measurement methods. Methods: Consecutive adult (nonaneurysmal) patients being surgically treated for heart disease (mean age, 51 +/- 11 years; range, 29-76 years; N = 25) were included in this study. All patients underwent transthoracic echocardiography (TTE), computed tomography angiography (CTA), and intraoperative ultrasound (IOUS). Anteroposterior diameters were measured at 1 cm above the junction of the aortic sinus, the proximal 1 cm of the innominate artery, and the midpoint of the two. Results: The average diameter of the proximal ascending aorta in systole/diastole measured by IOUS was 32.07 +/- 2.03/30.27 +/- 2.05 mm (paired t-test: difference, 1.80 +/- 0.46 mm; P < .001). The average diameters of the proximal ascending aorta measured by nonelectrocardiography-gated CTA and TTE were 31.45 +/- 1.97 mm and 29.7 +/- 1.84 mm, respectively. The average diameter of the mid and distal ascending aorta in systole/diastole measured by IOUS was 32.35 +/- 1.95/30.57 +/- 1.94 mm (paired t-test: difference, 1.78 +/- 0.44 mm; P < .001) and 32.32 +/- 1.92/30.67 +/- 1.90 mm (paired t-test: difference, 1.65 +/- 0.42 mm; P < .001), respectively. The average diameter of themid and distal ascending aorta measured by CTA was 31.74 +/- 1.92 mm and 31.59 +/- 1.96 mm, respectively. At each location, the difference in the aortic diameter between systole and diastole was statistically significant (all P values < .001; paired t-test). The minimum and maximum changes in the diameter between systole and diastole were 0.90 mm and 2.70 mm. In all, 96% (24/25) of the average diameters derived from IOUS and CTA at the three locations were within the concordance limit in systole, and 92% to 100% (23/25 to 25/25) were within the concordance limit in diastole. The average diameters derived from IOUS and TTE images of the proximal ascending aorta were within the bounds of the concordance limit 92% (23/25) of the time in systole and 100% (25/25) of the time in diastole. The average diameters derived from CTA and TTE images of the proximal ascending aorta were within the bounds of the concordance limit 88%(22/25) of the time. Pearson correlation coefficients between these groups ranged from 0.905 to 0.982 (all P values < . 01). Conclusions: The ascending aorta diameters measured by nonelectrocardiography-gated CTA and TTE were consistent with the IOUS measurements.
引用
收藏
页码:1538 / 1544
页数:7
相关论文
共 50 条
  • [41] Through-Plane Movement at Multiple Aortic Levels on Dynamic Computed Tomography Angiography Is Limited in Patients With an Abdominal Aortic Aneurysm
    de Jonge, Jeroen C.
    Zandvoort, Herman J. A.
    Vonken, Evert-Jan P. A.
    Moll, Frans L.
    van Herwaarden, Joost A.
    JOURNAL OF ENDOVASCULAR THERAPY, 2015, 22 (05) : 765 - 769
  • [42] Effect of injection duration on contrast enhancement during cardiac computed tomography angiography in newborns and infants
    Masuda, T.
    Funama, Y.
    Nakaura, T.
    Sato, T.
    Tahara, M.
    Masuda, S.
    Yoshiura, T.
    Gotanda, R.
    Arao, K.
    Imaizumi, H.
    Arao, S.
    Hiratsuka, J.
    Awai, K.
    RADIOGRAPHY, 2022, 28 (02) : 440 - 446
  • [43] Dual-source computed tomography for evaluating pulmonary artery in pediatric patients with cyanotic congenital heart disease: Comparison with transthoracic echocardiography
    Shi, Ke
    Yang, Zhi-gang
    Xu, Hua-yan
    Zhao, Si-xiu
    Liu, Xi
    Guo, Ying-kun
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (01) : 187 - 192
  • [44] Prosthesis-patient mismatch defined by cardiac computed tomography versus echocardiography after transcatheter aortic valve replacement
    Fukui, Miho
    Garcia, Santiago
    Lesser, John R.
    Gossl, Mario
    Tang, Liang
    Caye, David
    Newell, Marc
    Hashimoto, Go
    Lopes, Bernardo B. C.
    Stanberry, Larissa, I
    Enriquez-Sarano, Maurice
    Pibarot, Philippe
    Hahn, RebeccaT
    Sorajja, Paul
    Cavalcante, Joao L.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2021, 15 (05) : 403 - 411
  • [45] Assessment of thoracic aortic conformational changes by four-dimensional computed tomography angiography in patients with chronic aortic dissection type b
    Weber, Tim F.
    Ganten, Maria-Katharina
    Boeckler, Dittmar
    Geisbuesch, Philipp
    Kopp-Schneider, Annette
    Kauczor, Hans-Ulrich
    von Tengg-Kobligk, Hendrik
    EUROPEAN RADIOLOGY, 2009, 19 (01) : 245 - 253
  • [46] Cardiac Computed Tomography-Derived Left Atrial Strain and Volume in Pediatric Patients With Congenital Heart Disease: A Comparative Analysis With Transthoracic Echocardiography
    Xie, Wei-Hui
    Chen, Li-Jun
    Hu, Li-Wei
    Ouyang, Rong-Zhen
    Guo, Chen
    Sun, Ai-Min
    Wang, Qian
    Qiu, Hai-Sheng
    Zhang, Yu-Qi
    Zhang, Hao
    Fu, Qi-Hua
    Zhong, Yu-Min
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [47] Feasibility of aortic valve assessment with low dose prospectively triggered adaptive systolic (PTAS) cardiac computed tomography angiography
    Lee A.M.
    Beaudoin J.
    Thai W.-E.
    Wai B.
    Hui G.C.
    Sidhu M.S.
    Engel L.-C.
    Abbara S.
    Hoffmann U.
    Ghoshhajra B.B.
    BMC Research Notes, 6 (1)
  • [48] Assessment of thoracic aortic conformational changes by four-dimensional computed tomography angiography in patients with chronic aortic dissection type b
    Tim F. Weber
    Maria-Katharina Ganten
    Dittmar Böckler
    Philipp Geisbüsch
    Annette Kopp-Schneider
    Hans-Ulrich Kauczor
    Hendrik von Tengg-Kobligk
    European Radiology, 2009, 19 : 245 - 253
  • [49] Bicuspid aortic valve annulus: assessment of geometry and size changes during the cardiac cycle as measured with a standardized method to define the annular plane
    Sara Boccalini
    Lidia R. Bons
    Allard T. van den Hoven
    Annemien E. van den Bosch
    Gabriel P. Krestin
    Jolien Roos-Hesselink
    Ricardo P. J. Budde
    European Radiology, 2021, 31 : 8116 - 8129
  • [50] Feasibility and accuracy of three-dimensional transthoracic echocardiography vs. multidetector computed tomography in the evaluation of aortic valve annulus in patient candidates to transcatheter aortic valve implantation
    Tamborini, Gloria
    Fusini, Laura
    Muratori, Manuela
    Cefalu, Claudia
    Gripari, Paola
    Ali, Sarah Ghulam
    Pontone, Gianluca
    Andreini, Daniele
    Bartorelli, Antonio L.
    Alamanni, Francesco
    Fiorentini, Cesare
    Pepi, Mauro
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (12) : 1316 - 1323