Comparison of dynamic changes in aortic diameter during the cardiac cycle measured by computed tomography angiography and transthoracic echocardiography

被引:11
|
作者
Huang, Jian [1 ,2 ]
Wang, Yongsheng [1 ]
Lin, Lin [3 ]
Li, Zhibin [4 ]
Shan, Zhonggui [2 ]
Zheng, Shaoyi [1 ]
机构
[1] Southern Med Univ, Nanfang Hosp, Dept Cardiovasc Surg, Sch Clin Med 1, 1023 S Shatai Rd, Guangzhou 510515, Guangdong, Peoples R China
[2] Xiamen Univ, Affiliated Hosp 1, Dept Cardiovasc Surg, Xiamen, Peoples R China
[3] Xiamen Univ, Affiliated Hosp 1, Cent Lab, Xiamen, Peoples R China
[4] Xiamen Univ, Affiliated Hosp 1, Epidemiol Res Unit, Xiamen, Peoples R China
关键词
Aortic diameter; Transthoracic echocardiography; Computed tomography angiography; Intraoperative ultrasound; Dynamic change; ASSOCIATION; DISSECTION; SOCIETY; IMPACT;
D O I
10.1016/j.jvs.2018.07.083
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This study aimed to examine the relationship between dynamic changes in aortic diameter and corresponding measurement methods. Methods: Consecutive adult (nonaneurysmal) patients being surgically treated for heart disease (mean age, 51 +/- 11 years; range, 29-76 years; N = 25) were included in this study. All patients underwent transthoracic echocardiography (TTE), computed tomography angiography (CTA), and intraoperative ultrasound (IOUS). Anteroposterior diameters were measured at 1 cm above the junction of the aortic sinus, the proximal 1 cm of the innominate artery, and the midpoint of the two. Results: The average diameter of the proximal ascending aorta in systole/diastole measured by IOUS was 32.07 +/- 2.03/30.27 +/- 2.05 mm (paired t-test: difference, 1.80 +/- 0.46 mm; P < .001). The average diameters of the proximal ascending aorta measured by nonelectrocardiography-gated CTA and TTE were 31.45 +/- 1.97 mm and 29.7 +/- 1.84 mm, respectively. The average diameter of the mid and distal ascending aorta in systole/diastole measured by IOUS was 32.35 +/- 1.95/30.57 +/- 1.94 mm (paired t-test: difference, 1.78 +/- 0.44 mm; P < .001) and 32.32 +/- 1.92/30.67 +/- 1.90 mm (paired t-test: difference, 1.65 +/- 0.42 mm; P < .001), respectively. The average diameter of themid and distal ascending aorta measured by CTA was 31.74 +/- 1.92 mm and 31.59 +/- 1.96 mm, respectively. At each location, the difference in the aortic diameter between systole and diastole was statistically significant (all P values < .001; paired t-test). The minimum and maximum changes in the diameter between systole and diastole were 0.90 mm and 2.70 mm. In all, 96% (24/25) of the average diameters derived from IOUS and CTA at the three locations were within the concordance limit in systole, and 92% to 100% (23/25 to 25/25) were within the concordance limit in diastole. The average diameters derived from IOUS and TTE images of the proximal ascending aorta were within the bounds of the concordance limit 92% (23/25) of the time in systole and 100% (25/25) of the time in diastole. The average diameters derived from CTA and TTE images of the proximal ascending aorta were within the bounds of the concordance limit 88%(22/25) of the time. Pearson correlation coefficients between these groups ranged from 0.905 to 0.982 (all P values < . 01). Conclusions: The ascending aorta diameters measured by nonelectrocardiography-gated CTA and TTE were consistent with the IOUS measurements.
引用
收藏
页码:1538 / 1544
页数:7
相关论文
共 50 条
  • [1] Multimodality Assessment of Thoracic Aortic Dimensions Comparison of Computed Tomography Angiography, Magnetic Resonance Imaging, and Echocardiography Measurements
    Frazao, Caio
    Tavoosi, Anahita
    Wintersperger, Bernd J.
    Nguyen, Elsie T.
    Wald, Rachel M.
    Ouzounian, Maral
    Hanneman, Kate
    JOURNAL OF THORACIC IMAGING, 2020, 35 (06) : 399 - 406
  • [2] Multimodality Imaging of Aortic Dimensions: Comparison of Transthoracic Echocardiography with Multidetector Row Computed Tomography
    Tsang, James F.
    Lytwyn, Matthew
    Farag, Ashraf
    Zeglinski, Matthew
    Wallace, Kerrett
    daSilva, Megan
    Bohonis, Sheena
    Walker, Jonathan R.
    Tam, James W.
    Strzelczyk, Jacek
    Jassal, Davinder S.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (06): : 735 - 741
  • [3] The effect of aortic area measurement site on the energy loss coefficient: a comparison between echocardiography and cardiac computed tomography angiography in patients with aortic stenosis
    Yaari, Dotan
    Rubinshtein, Ronen
    Sachner, Robert
    Gaspar, Tamar
    Adawi, Salim
    Jaffe, Ronen
    Asmer, Ihab
    Ganaeem, Majdi
    Shiran, Avinoam
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2016, 33 (11): : 1649 - 1655
  • [4] Dynamic aortic changes during the cardiac cycle in patients with aortic valve disease analyzed by computed tomography combined with PhyZiodynamics software
    Togo Norimatsu
    Nobuo Iguchi
    Mitsuaki Isobe
    The International Journal of Cardiovascular Imaging, 2023, 39 : 2073 - 2082
  • [5] Dynamic aortic changes during the cardiac cycle in patients with aortic valve disease analyzed by computed tomography combined with PhyZiodynamics software
    Norimatsu, Togo
    Iguchi, Nobuo
    Isobe, Mitsuaki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2023, 39 (10) : 2073 - 2082
  • [6] Aortic valve area assessed with 320-detector computed tomography: comparison with transthoracic echocardiography
    Larsen, Linnea Hornbech
    Kofoed, Klaus Fuglsang
    Carstensen, Helle Gervig
    Mejdahl, Mads Rams
    Andersen, Mads Jonsson
    Kjaergaard, Jesper
    Nielsen, Olav Wendelboe
    Kober, Lars
    Mogelvang, Rasmus
    Hassager, Christian
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (01) : 165 - 173
  • [7] Aortic valve area assessed with 320-detector computed tomography: comparison with transthoracic echocardiography
    Linnea Hornbech Larsen
    Klaus Fuglsang Kofoed
    Helle Gervig Carstensen
    Mads Rams Mejdahl
    Mads Jønsson Andersen
    Jesper Kjaergaard
    Olav Wendelboe Nielsen
    Lars Køber
    Rasmus Møgelvang
    Christian Hassager
    The International Journal of Cardiovascular Imaging, 2014, 30 : 165 - 173
  • [8] Comparison of transthoracic echocardiography with computed tomography in evaluation of pulmonary veins
    Dong, Qing-Qing
    Yang, Wen-Yi
    Sun, Ya-Ping
    Zhang, Qian
    Chu, Guang
    Zhou, Gen-Qing
    Chen, Gang
    Chen, Song-Wen
    Liu, Shao-Wen
    Wang, Fang
    BMC CARDIOVASCULAR DISORDERS, 2019, 19 (01)
  • [9] Comparison of transthoracic echocardiography with computed tomography in evaluation of pulmonary veins
    Qing-Qing Dong
    Wen-Yi Yang
    Ya-Ping Sun
    Qian Zhang
    Guang Chu
    Gen-Qing Zhou
    Gang Chen
    Song-Wen Chen
    Shao-Wen Liu
    Fang Wang
    BMC Cardiovascular Disorders, 19
  • [10] Comparison of Aortic Annulus Size by Transesophageal Echocardiography and Computed Tomography Angiography With Direct Surgical Measurement
    Wang, Hanghang
    Hanna, Jennifer M.
    Ganapathi, Asvin
    Keenan, Jeffrey E.
    Hurwitz, Lynne M.
    Vavalle, John P.
    Kiefer, Todd L.
    Wang, Andrew
    Harrison, J. Kevin
    Hughes, G. Chad
    AMERICAN JOURNAL OF CARDIOLOGY, 2015, 115 (11) : 1568 - 1573