Reference points for radial head prosthesis size

被引:97
作者
Doornberg, JN
Linzel, DS
Zurakowski, D
Ring, D
机构
[1] Massachusetts Gen Hosp, Orthopaed Hand & Upper Extrem Serv, Yawkey Ctr, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Dept Orthopaed Surg, Boston, MA USA
[3] Childrens Hosp, Dept Biostat, Boston, MA USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2006年 / 31A卷 / 01期
关键词
coronoid; elbow; fracture; injury patterns;
D O I
10.1016/j.jhsa.2005.06.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Metallic radial head implants are useful when the radial head cannot be repaired reliably and when either the elbow or the forearm is unstable. Problems arise when the radial head prosthesis is too thick, causing erosions of the capitellum and incongruity of the ulnohumeral joint. We used quantitative 3-dimensional computed tomography analysis to investigate the relative height of the radial head relative to the lateral edge and central ridge of the coronoid process as reference points for optimal insertion of a radial head prosthesis. Methods: Seventeen computed tomography scans of the elbow were analyzed. The anatomic coronal plane of the forearm was determined using 3-dimensional images and a 2-dimensional image bisecting the articular surface of the radial head was created in this plane. The distance between the plane of the articular surface of the radial head and parallel planes at the most proximal aspect of the coronoid (the central ridge) and the lateral edge of the coronoid articular surface were measured. Negative values indicate the radial head is proximal to the coronoid. Results: The average distance between the planes defined by the radial head articular surface and the coronoid central ridge was -0.8 nim. The average distance between the planes defined by the radial head articular surface and the lateral edge of the coronoid articular surface was -0.9 mm. Conclusions: Because the radial head was on average only 0.9 mm more proximal than the lateral edge of the coronoid process and because the key is to not overstuff the joint a useful general guideline would be to place the plane of the articular surface of the radial head even with or just slightly more proximal than the lateral edge of the coronoid articular surface. Considering the substantial variability of the normal height of the articular surface of the radial head with respect to that of the coronoid, preoperative radiographs of the opposite elbow may be useful to avoid overstuffing the elbow.
引用
收藏
页码:53 / 57
页数:5
相关论文
共 22 条
[1]   Management of mason type-III radial head fractures with a titanium prosthesis, ligament repair, and early mobilization [J].
Ashwood, N ;
Bain, GI ;
Unni, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (02) :274-280
[2]   Prosthetic radial head components and proximal radial morphology: A mismatch [J].
Beredjiklian, PK ;
Nalbantoglu, U ;
Potter, HG ;
Hotchkiss, RN .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 1999, 8 (05) :471-475
[3]  
Captier G, 2002, SURG RADIOL ANAT, V24, P295, DOI 10.1007/s00276-002-0059-9
[4]   Biomechanical and computer analysis of radial head prostheses [J].
Gupta, GG ;
Lucas, G ;
Hahn, DL .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 1997, 6 (01) :37-48
[5]   The functional outcome with metallic redial head implants in the treatment of unstable elbow fractures: A long-term review [J].
Harrington, IJ ;
Sekyi-Otu, A ;
Barrington, TW ;
Evans, DC ;
Tuli, V .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2001, 50 (01) :46-52
[6]   REPLACEMENT OF THE RADIAL HEAD IN THE TREATMENT OF UNSTABLE ELBOW FRACTURES [J].
HARRINGTON, IJ ;
TOUNTAS, AA .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1981, 12 (05) :405-412
[7]  
Heim U, 1992, Z Unfallchir Versicherungsmed, V85, P3
[8]  
KING G, 2002, EVOLVE MODULAR RADIA
[9]  
King G J, 1991, J Orthop Trauma, V5, P21, DOI 10.1097/00005131-199103000-00004
[10]   An anthropometric study of the radial head - Implications in the design of a prosthesis [J].
King, GJW ;
Zarzour, ZDS ;
Patterson, SD ;
Johnson, JA .
JOURNAL OF ARTHROPLASTY, 2001, 16 (01) :112-116