Optimal design of an array of active tuned mass dampers for wind-exposed high-rise buildings

被引:41
作者
Venanzi, Ilaria [1 ]
Ubertini, Filippo [1 ]
Materazzi, Annibale Luigi [1 ]
机构
[1] Univ Perugia, I-06125 Perugia, Italy
关键词
hybrid control system; optimal design; tall buildings; wind-excited vibrations; translational and torsional response; RESPONSE CONTROL; OPTIMIZATION; PERFORMANCE; ATMD;
D O I
10.1002/stc.1502
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, a comprehensive procedure is developed for the optimization of a hybrid control system for tall buildings subjected to wind-induced vibrations. The control system is made of active tuned mass dampers (ATMDs) and is conceived to mitigate the flexural and torsional response in serviceability limit state conditions. The feedback information necessary to compute the control forces is provided by a limited number of accelerometers arranged over the building's height. To reduce the computational effort, subsequent optimization subprocedures are employed that take advantage of the genetic algorithm to find the solution of the nonlinear, constrained optimization problems. At first, the optimization of the ATMDs' number and positions over the top floor of the building is carried out. Then, the optimal location of the accelerometers over the building's height is obtained. The reduction of the flexural and torsional accelerations is chosen as target of the optimization problem. The technical limitations of the ATMDs, such as the actuators saturation and the limited stroke extensions, are the constraints to the problem. As an illustrative example, a control system is optimized for the response mitigation of a tall building subjected to wind load. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:903 / 917
页数:15
相关论文
共 27 条
[1]   Multiobjective optimal fuzzy logic control system for response control of wind-excited tall buildings [J].
Ahlawat, AS ;
Ramaswamy, A .
JOURNAL OF ENGINEERING MECHANICS, 2004, 130 (04) :524-530
[2]   Simple ATMD control methodology for tall buildings subject to wind loads [J].
Ankireddi, S ;
Yang, HTY .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1996, 122 (01) :83-91
[3]   Performance of Multi-TMD in the Towers of Suspension Bridges [J].
Casciati, F. ;
Giuliano, F. .
JOURNAL OF VIBRATION AND CONTROL, 2009, 15 (06) :821-847
[4]   An active mass damper system for structural control using real-time wireless sensors [J].
Casciati, Sara ;
Chen, ZhiCong .
STRUCTURAL CONTROL & HEALTH MONITORING, 2012, 19 (08) :758-767
[5]   Optimal placement of active control devices and sensors in frame structures using multi-objective genetic algorithms [J].
Cha, Young-Jin ;
Raich, Anne ;
Barroso, Luciana ;
Agrawal, Anil .
STRUCTURAL CONTROL & HEALTH MONITORING, 2013, 20 (01) :16-44
[6]   Reliability based optimum design of Tuned Mass Damper in seismic vibration control of structures with bounded uncertain parameters [J].
Chakraborty, Subrata ;
Roy, Bijan Kumar .
PROBABILISTIC ENGINEERING MECHANICS, 2011, 26 (02) :215-221
[7]   Mass dampers and their optimal designs for building vibration control [J].
Chang, CC .
ENGINEERING STRUCTURES, 1999, 21 (05) :454-463
[8]  
Chu S.Y., 2005, ACTIVE HYBRID SEMIAC
[9]   Optimal tuned mass damper for seismic applications and practical design formulas [J].
Hoang, Nam ;
Fujino, Yozo ;
Warnitchai, Pennung .
ENGINEERING STRUCTURES, 2008, 30 (03) :707-715
[10]  