Air-lift internal loop biofilm reactor for realized simultaneous nitrification and denitrification

被引:9
作者
Zhang, Cuiyi [1 ]
Wang, Lu [1 ]
Yan, Ning [1 ]
Zhang, Yongming [1 ]
Liu, Rui [2 ]
机构
[1] Shanghai Normal Univ, Dept Environm Engn, Shanghai 200234, Peoples R China
[2] Tsinghua Univ, Yangtze Delta Reg Inst, Dept Environm Technol & Ecol, Zhejiang Prov Key Lab Water Sci & Technol, Jiaxing 314006, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Biofilm; Reactor; Simultaneous nitrification and denitrification; Microelectrode; NITROGEN-REMOVAL; WATER; MEMBRANE;
D O I
10.1007/s00449-012-0814-1
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Simultaneous nitrification and denitrification (SND) was realized by means of a novel air-lift internal loop biofilm reactor, in which aeration was set in middle of the reactor. During operation, the aeration was adjusted to get appropriate dissolve oxygen (DO) in bulk solution and let aerobic and anoxic zone coexist in one reactor. When aeration was at 0.6 and 0.2 L/min, corresponding to DO of 5.8 and 2.5 mg/L in bulk solution, ammonia nitrogen removal percentage reached about 80 and 90 %, but total nitrogen removal percentage was lower than 25 %. While the aeration was reduced to 0.1 L/min, aerobic and anoxic zones existed simultaneously in one reactor to get 75 % of ammonia nitrogen and 50 % of total nitrogen removal percentage. Biofilms were, respectively, taken from aerobic and anoxic zone to verify their function of nitrification and denitrification in two flasks, in which ammonia nitrogen was transferred into nitrate completely by aerobic biofilm, and nitrate was removed more than 80 % by anoxic biofilm. Microelectrode was used to measure the DO distribution inside biofilms in anoxic zone corresponding to different aerations. When aeration was at 0.6 and 0.2 L/min, DO inside biofilm was more than 1.5 mg/L, but the DO inside biofilm decreased to anoxic status with depth of biofilm increasing corresponding to aeration of 0.1 L/min. The experimental results indicated that SND could be realized because of simultaneous existence of aerobic and anoxic biofilms in one reactor.
引用
收藏
页码:597 / 602
页数:6
相关论文
共 19 条
[1]  
[Anonymous], 2001, STANDARD METHODS EXA
[2]  
Collivignarelli C, 1999, WATER SCI TECHNOL, V40, P187, DOI 10.1016/S0273-1223(99)00575-2
[3]   Extensive nitrogen removal in a new type of airlift reactor [J].
Frijters, CTMJ ;
Vellinga, S ;
Jorna, T ;
Mulder, R .
WATER SCIENCE AND TECHNOLOGY, 2000, 41 (4-5) :469-476
[4]   Factors affecting simultaneous nitrification and de-nitrification (SND) and its kinetics model in membrane bioreactor [J].
He, Sheng-bing ;
Xue, Gang ;
Wang, Bao-zhen .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 168 (2-3) :704-710
[5]   LARGE-SCALE ANAEROBIC-AEROBIC TREATMENT OF COMPLEX INDUSTRIAL-WASTE WATER USING BIOFILM REACTORS [J].
HEIJNEN, JJ ;
MULDER, A ;
WELTEVREDE, R ;
HOLS, J ;
VANLEEUWEN, HLJM .
WATER SCIENCE AND TECHNOLOGY, 1991, 23 (7-9) :1427-1436
[6]   COD, ammonia and dissolved oxygen time profiles in the simultaneous nitrification/denitrification process [J].
Holman, JB ;
Wareham, DG .
BIOCHEMICAL ENGINEERING JOURNAL, 2005, 22 (02) :125-133
[7]  
Kugleman I.J., 1991, Environ. Eng, P312
[8]   BIOFILM CHARACTERIZATION AND ACTIVITY ANALYSIS IN WATER AND WASTE-WATER TREATMENT [J].
LAZAROVA, V ;
MANEM, J .
WATER RESEARCH, 1995, 29 (10) :2227-2245
[9]   Effects of COD/N ratio and DO concentration on simultaneous nitrification and denitrification in an airlift internal circulation membrane bioreactor [J].
Meng Qingjuan ;
Yang Fenglin ;
Liu Lifen ;
Meng Fangang .
JOURNAL OF ENVIRONMENTAL SCIENCES, 2008, 20 (08) :933-939
[10]   Nitrogen-removal bioreactor capable of simultaneous nitrification and denitrification for application to industrial wastewater treatment [J].
Morita, Masahiko ;
Uemoto, Hiroaki ;
Watanabe, Atsushi .
BIOCHEMICAL ENGINEERING JOURNAL, 2008, 41 (01) :59-66