Biomechanical studies on cervical total disc arthroplasty: A literature review

被引:62
作者
Galbusera, Fabio [1 ]
Bellini, Chiara M. [1 ]
Brayda-Bruno, Marco [1 ]
Fornari, Maurizio [1 ]
机构
[1] IRCCS Ist Ortoped Galeazzi, I-20161 Milan, Italy
关键词
Cervical; Total disc arthroplasty; Biomechanics; Motion preservation; Spinal alignment;
D O I
10.1016/j.clinbiomech.2008.06.002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background Many models of cervical disc prostheses are currently commercially available or under clinical trial, and are based on several design concepts and built employing different materials. This paper is targeted to the understanding of the possible relationships between the geometrical, mechanical and material properties of the various cervical disc prostheses and the restoration of a correct biomechanics of the implanted spine. Methods. Papers about cervical disc arthroplasty, based on ex vivo testing, mathematical models, and radiographic measurements, were included in the present review. Findings. Although disc arthroplasty was found to be generally able to preserve a nearly physiological motion in the cervical spine, several alterations in the spine biomechanics due to disc arthroplasty were reported in the literature. An increase of the range of motion at the implanted level was observed in some ex vivo studies. Loss of mobility and heterotopic ossification were reported in radiographic investigations. Loss of lordosis at the implanted level was detected as well. Wear debris was usually found very limited and device stability seemed not to be an actual problem. Interpretation. The possible relationships between the observed alterations in the spine biomechanics after disc arthroplasty and the properties of the various cervical disc prostheses have been reviewed. Clinical studies are needed to assess the validity of the considerations inferred from the biomechanical papers. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1095 / 1104
页数:10
相关论文
共 73 条
  • [1] Albert Todd J, 2004, Spine J, V4, p292S, DOI 10.1016/j.spinee.2004.07.023
  • [2] INSTANTANEOUS AXES OF ROTATION OF THE TYPICAL CERVICAL MOTION SEGMENTS - A STUDY IN NORMAL VOLUNTEERS
    AMEVO, B
    WORTH, D
    BOGDUK, N
    [J]. CLINICAL BIOMECHANICS, 1991, 6 (02) : 111 - 117
  • [3] A comparison of simulator-tested and -retrieved cervical disc prostheses
    Anderson, PA
    Rouleau, JP
    Toth, JM
    Riew, KD
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2004, 1 (02) : 202 - 210
  • [4] Wear analysis of the Bryan Cervical Disc prosthesis
    Anderson, PA
    Rouleau, JP
    Bryan, VE
    Carlson, CS
    [J]. SPINE, 2003, 28 (20) : S186 - S194
  • [5] Anderson Paul A, 2004, Spine J, V4, p303S, DOI 10.1016/j.spinee.2004.07.026
  • [6] FUSION AROUND CERVICAL DISC PROSTHESIS: CASE REPORT
    Bartels, Ronald H. M. A.
    Donk, Roland
    [J]. NEUROSURGERY, 2005, 57 (01) : E194 - +
  • [7] Early results after ProDisc-C cervical disc replacement
    Bertagnoli, R
    Yue, JJ
    Pfeiffer, F
    Fenk-Mayer, A
    Lawrence, JP
    Kershaw, T
    Nanieva, R
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2005, 2 (04) : 403 - 410
  • [8] Indications for full prosthetic disc arthroplasty: a correlation of clinical outcome against a variety of indications
    Bertagnoli, R
    Kumar, S
    [J]. EUROPEAN SPINE JOURNAL, 2002, 11 (Suppl 2) : S131 - S136
  • [9] Biomechanics of the cervical spine. I: Normal kinematics
    Bogduk, N
    Mercer, S
    [J]. CLINICAL BIOMECHANICS, 2000, 15 (09) : 633 - 648
  • [10] The impact of total lumbar disc replacement on segmental and total lumbar lordosis
    Cakir, B
    Richter, M
    Käfer, W
    Puhl, W
    Schmidt, R
    [J]. CLINICAL BIOMECHANICS, 2005, 20 (04) : 357 - 364