Influence of additional astigmatism on distance-corrected near visual acuity and reading performance

被引:25
作者
Casagrande, Maria [1 ]
Baumeister, Martin [1 ]
Buehren, Jens [1 ]
Klaproth, Oliver K. [1 ]
Titke, Christine [1 ]
Kohnen, Thomas [1 ]
机构
[1] Goethe Univ Frankfurt, Dept Ophthalmol, D-60590 Frankfurt, Germany
关键词
MONOFOCAL INTRAOCULAR LENSES; PUPIL SIZE; VISION; EYES; TROPICAMIDE; REFRACTION; SPEED;
D O I
10.1136/bjophthalmol-2013-303066
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim To investigate the effect of astigmatism on near vision performance. Methods In a consecutive case series 23 eyes of 23 participants were fogged with 0 D, -0.75 D and -1.5 D of with-the-rule (WTR) and against-the-rule (ATR) astigmatism (cylindrical lenses without spherical compensation). All subjects were cyclopleged and distance corrected. Reading acuity (RAc) and speed (RS) were measured with standardised sentences, near visual acuity (NVA) was assessed using single optotypes (Snellen E), all presented on a thin film transistor display using the Salzburg Reading Desk (SRD). Data were analysed using Wilcoxon-matched-pairs test, regression analysis and Bland-Altman analysis. Results An increasing amount of astigmatism resulted in a decreased NVA (p=0.16 for -0.75 D, p=0.005 for -1.5 D) and RAc (p=0.002 for -0.75 D, p=0.014 for -1.5 D). WTR astigmatism caused a reduced NVA, RAc and lower RS compared with ATR astigmatism (p<0.001). NVA was better than RAc with no astigmatism, -0.75 D WTR and -1.5 D WTR (p=0.03 for 0 D, p<0.001 for -0.75 D, p=0.03 for -1.5 D). There was no difference between NVA and RAc for -0.75 D ATR and -1.5 D ATR (p=0.06 for -0.75 D, p=0.5 for -1.5 D). Conclusions WTR astigmatism results in reduced reading parameters and NVA for -0.75 D and -1.5 D astigmatism compared with corresponding ATR astigmatism and no astigmatism added. No beneficial effect of astigmatism was detected.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 24 条
[1]   Noticeable, troublesome and objectionable limits of blur [J].
Atchison, DA ;
Fisher, SW ;
Pedersen, CA ;
Ridall, PG .
VISION RESEARCH, 2005, 45 (15) :1967-1974
[2]  
BAILEY IL, 1976, AM J OPTOM PHYS OPT, V53, P740
[3]   OPTIMAL POSTOPERATIVE REFRACTION FOR GOOD UNAIDED NEAR AND DISTANCE VISION WITH MONOFOCAL INTRAOCULAR LENSES [J].
BRADBURY, JA ;
HILLMAN, JS ;
CASSELLSBROWN, A .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1992, 76 (05) :300-302
[4]   Device for Improving Quantification of Reading Acuity and Reading Speed [J].
Dexl, Alois K. ;
Schloegel, Horst ;
Wolfbauer, Michael ;
Grabner, Guenther .
JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (09) :682-688
[5]   Cycloplegic effect of 0.5% tropicamide and 0.5% phenylephrine mixed eye drops: Objective assessment in japanese schoolchildren with myopia [J].
Hamasaki, Ichiro ;
Hasebe, Satoshi ;
Kimura, Shuhei ;
Miyata, Manabu ;
Ohtsuki, Hiroshi .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 2007, 51 (02) :111-115
[6]   Effect of astigmatism on visual acuity in eyes with a diffractive multifocal intraocular lens [J].
Hayashi, Ken ;
Manabe, Shin-ichi ;
Yoshida, Motoaki ;
Hayashi, Hideyuki .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (08) :1323-1329
[7]  
Huber C, 1981, J Am Intraocul Implant Soc, V7, P244
[8]   Effect of pupil size on uncorrected visual acuity in astigmatic eyes [J].
Kamiya, Kazutaka ;
Kobashi, Hidenaga ;
Shimizu, Kimiya ;
Kawamorita, Takushi ;
Uozato, Hiroshi .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2012, 96 (02) :267-270
[9]  
Manny RE, 2001, INVEST OPHTH VIS SCI, V42, P1728
[10]   Effect of small focal errors on vision [J].
Miller, AD ;
Kris, MJ ;
Griffiths, AC .
OPTOMETRY AND VISION SCIENCE, 1997, 74 (07) :521-526