Critical factors in the measurement of tablet film coatings using terahertz pulsed imaging

被引:16
作者
Brock, Daniela [1 ]
Zeitler, J. Axel [2 ]
Funke, Adrian [3 ]
Knop, Klaus [1 ]
Kleinebudde, Peter [1 ]
机构
[1] Univ Dusseldorf, Inst Pharmaceut & Biopharmaceut, D-40225 Dusseldorf, Germany
[2] Univ Cambridge, Dept Chem Engn & Biotechnol, Cambridge CB2 3RA, England
[3] Bayer Pharma AG, Global Chem & Pharmaceut Dev, D-13353 Berlin, Germany
关键词
terahertz pulsed imaging; active coating; deconvolution; absorption coefficient; coating thickness; refractive index; imaging methods; crystallinity; osmotic pumps; solid dosage form; SPECTROSCOPY; THICKNESS; OPERATION; TIME;
D O I
10.1002/jps.23521
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The present work gives an insight into some key measurement and signal processing considerations in terahertz pulsed imaging (TPI). TPI is increasingly used for the measurement of the spatial variation of coating thickness on coated solid dosage forms. The potential of TPI for the assessment of coating thickness distributions and the use in process development is described in recent literature. However, some critical factors need to be taken into account when working with this technique. These are (1) the signal processing of the raw data, (2) the influence of the composition of the sample matrix on the TPI signals and subsequent coating analysis, (3) signal distortions that can occur at tablet edges or areas with defects, and (4) the refractive index as a key parameter in the quantification of layer thickness. In this paper, we will highlight to what extent these factors impact on the qualitative and quantitative analysis of TPI data and how artifacts and misinterpretation of data can be avoided to ensure fully quantitative and robust measurements. (c) 2013 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 102:18131824, 2013
引用
收藏
页码:1813 / 1824
页数:12
相关论文
共 18 条
  • [1] Understanding the influence of polymorphism on phonon spectra: Lattice dynamics calculations and terahertz spectroscopy of carbamazepine
    Day, GM
    Zeitler, JA
    Jones, W
    Rades, T
    Taday, PF
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 2006, 110 (01) : 447 - 456
  • [2] PRACTICAL CONE-BEAM ALGORITHM
    FELDKAMP, LA
    DAVIS, LC
    KRESS, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06): : 612 - 619
  • [3] Development of a Process Analytical Technology (PAT) for in-line monitoring of film thickness and mass of coating materials during a pan coating operation
    Gendre, Claire
    Genty, Muriel
    Boiret, Mathieu
    Julien, Marc
    Meunier, Loic
    Lecoq, Olivier
    Baron, Michel
    Chaminade, Pierre
    Pean, Jean Manuel
    [J]. EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2011, 43 (04) : 244 - 250
  • [4] Analysis of sustained-release tablet film coats using terahertz pulsed imaging
    Ho, L.
    Mueller, R.
    Romer, M.
    Gordon, K. C.
    Heinamaki, J.
    Kleinebudde, P.
    Pepper, M.
    Rades, T.
    Shen, Y. C.
    Strachan, C. J.
    Taday, P. F.
    Zeitler, J. A.
    [J]. JOURNAL OF CONTROLLED RELEASE, 2007, 119 (03) : 253 - 261
  • [5] Applications of terahertz pulsed imaging to sustained-release tablet film coating quality assessment and dissolution performance
    Ho, Louise
    Mueller, Ronny
    Gordon, Keith C.
    Kleinebudde, Peter
    Pepper, Michael
    Rades, Thomas
    Shen, Yaochun
    Taday, Philip F.
    Zeitler, J. Axel
    [J]. JOURNAL OF CONTROLLED RELEASE, 2008, 127 (01) : 79 - 87
  • [6] Monitoring the Film Coating Unit Operation and Predicting Drug Dissolution Using Terahertz Pulsed Imaging
    Ho, Louise
    Mueller, Ronny
    Gordon, Keith C.
    Kleinebudde, Peter
    Pepper, Michael
    Rades, Thomas
    Shen, Yaochun
    Taday, Philip F.
    Zeitler, J. Axel
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 2009, 98 (12) : 4866 - 4876
  • [7] Investigating Dissolution Performance Critical Areas on Coated Tablets: A Case Study Using Terahertz Pulsed Imaging
    Ho, Louise
    Mueller, Ronny
    Krueger, Cornelia
    Gordon, Keith C.
    Kleinebudde, Peter
    Pepper, Michael
    Rades, Thomas
    Shen, Yaochun
    Taday, Philip F.
    Zeitler, J. Axel
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 2010, 99 (01) : 392 - 402
  • [8] Terahertz pulsed imaging as an analytical tool for sustained-release tablet film coating
    Ho, Louise
    Mueller, Ronny
    Gordon, Keith C.
    Kleinebudde, Peter
    Pepper, Michael
    Rades, Thomas
    Shen, Yaochun
    Taday, Philip F.
    Zeitler, J. Axel
    [J]. EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2009, 71 (01) : 117 - 123
  • [9] Dynamic range in terahertz time-domain transmission and reflection spectroscopy
    Jepsen, PU
    Fischer, BM
    [J]. OPTICS LETTERS, 2005, 30 (01) : 29 - 31
  • [10] Terahertz In-Line Sensor for Direct Coating Thickness Measurement of Individual Tablets During Film Coating in Real-Time
    May, Robert K.
    Evans, Michael J.
    Zhong, Shuncong
    Warr, Ian
    Gladden, Lynn F.
    Shen, Yaochun
    Zeitler, J. Axel
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 2011, 100 (04) : 1535 - 1544