Low-dose CT for lung cancer screening: opportunities and challenges

被引:28
作者
Shen, Hongbing [1 ,2 ]
机构
[1] Nanjing Med Univ, Sch Publ Hlth, Dept Epidemiol, Nanjing 211166, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Collaborat Innovat Ctr Canc Med, Jiangsu Key Lab Canc Biomarkers Prevent & Treatme, Nanjing 211166, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
lung cancer; low-dose computerized tomography; early detection; opportunities; challenges; COST-EFFECTIVENESS; COMPUTED-TOMOGRAPHY; PULMONARY NODULES; SPIRAL CT; TRIAL; MANAGEMENT; SMOKERS; VOLUME; CHINA; SCAN;
D O I
10.1007/s11684-017-0600-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Lung cancer is among the most frequently diagnosed cancers worldwide and the leading cause of cancer death in both males and females. Screening for lung cancer coupled with earlier intervention has long been studied as an approach to mortality reduction. However, minimal progress was achieved until recently, when lowdose spiral computed tomography (LDCT) screening demonstrated a 20% reduction in mortality from lung cancer in a randomized controlled trial (RCT), the National Lung Screening Trial, from the United States. On the basis of this finding, LDCT has been recommended for lung cancer screening in high-risk populations by several clinical guidelines. However, results from the following independent RCTs in Europe failed to show consistent conclusions. In addition, intractable problems gradually emerged with the progress of LDCTscreening. This paper summarizes and discusses the main observations and challenges of LDCT screening for lung cancer. Before spreading implementation of LDCTscreening, challenges, including high false-positive rates, overdiagnosis, enormous costs, and radiation risk, must be addressed. Complementary biomarkers and technical improvement are expected in the field of lung cancer screening in the near future.
引用
收藏
页码:116 / 121
页数:6
相关论文
共 50 条
[41]   Systematic review of baseline low-dose CT lung cancer screening [J].
Yau, Gary ;
Lock, Michael ;
Rodrigues, George .
LUNG CANCER, 2007, 58 (02) :161-170
[42]   Lung Cancer Screening: Adjuncts and Alternatives to Low-Dose CT Scans [J].
Sanchez, Rolando Sanchez ;
Tanner, Nichole T. ;
Siddiqi, Nasar A. ;
Silvestri, Gerard A. .
CURRENT SURGERY REPORTS, 2013, 1 (04) :249-256
[43]   Lung Cancer Screening Program with Low-Dose CT in Greek Population [J].
Domvri, K. ;
Kontakiotis, T. ;
Lazaridis, G. ;
Spyratos, D. ;
Eleftheriadou, E. ;
Porpodis, K. ;
Tsiakitzis, K. ;
Lampaki, S. .
JOURNAL OF THORACIC ONCOLOGY, 2019, 14 (10) :S1012-S1013
[44]   Delivering low-dose CT screening for lung cancer: a pragmatic approach [J].
Horst, Carolyn ;
Dickson, Jennifer L. ;
Tisi, Sophie ;
Ruparel, Mamta ;
Nair, Arjun ;
Devaraj, Anand ;
Janes, Sam M. .
THORAX, 2020, 75 (10) :831-832
[45]   Lung Cancer Screening: Adjuncts and Alternatives to Low-Dose CT Scans [J].
Rolando Sanchez Sanchez ;
Nichole T. Tanner ;
Nasar A. Siddiqi ;
Gerard A. Silvestri .
Current Surgery Reports, 2013, 1 (4) :249-256
[46]   EXTRAPULMONARY MALIGNANCIES DIAGNOSED AT LOW-DOSE CT SCREENING FOR LUNG CANCER [J].
Rampinelli, Cristiano ;
Preda, Lorenzo ;
Maniglio, Marina ;
Veronesi, Giulia ;
Bellomi, Massimo .
JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (06) :S1391-S1392
[47]   Low-dose CT screening for lung cancer in Brazil: a study protocol [J].
dos Santos, Ricardo Sales ;
Franceschini, Juliana ;
Kay, Fernando Uliana ;
Chate, Rodrigo Caruso ;
da Silva Costa Junior, Altair ;
Galvao de Oliveira, Fernando Nunes ;
Cavalcante Trajano, Andre Luiz ;
Pereira, Jose Rodrigues ;
Succi, Jose Ernesto ;
Saad Junior, Roberto .
JORNAL BRASILEIRO DE PNEUMOLOGIA, 2014, 40 (02) :196-199
[48]   HUNCHEST projects-advancing low-dose CT lung cancer screening in Hungary [J].
Kerpel-Fronius, Anna ;
Bogos, Krisztina .
PATHOLOGY & ONCOLOGY RESEARCH, 2024, 30
[49]   Use of Imaging and Diagnostic Procedures After Low-Dose CT Screening for Lung Cancer [J].
Nishi, Shawn P. E. ;
Zhou, Jie ;
Okereke, Ikenna ;
Kuo, Yong-Fang ;
Goodwin, James .
CHEST, 2020, 157 (02) :427-434
[50]   Screening for lung cancer with low-dose computed tomography [J].
Diederich, S ;
Wormanns, D ;
Heindel, W .
RADIOLOGE, 2001, 41 (03) :256-260