An analytical method for computing voxel S values for electrons and photons

被引:30
作者
Amato, Ernesto [1 ]
Minutoli, Fabio [1 ]
Pacilio, Massimiliano [2 ]
Campenni, Alfredo [1 ]
Baldari, Sergio [1 ]
机构
[1] Univ Messina, Dept Radiol Sci, I-98125 Messina, Italy
[2] S Camillo Forlanini Hosp, Dept Med Phys, I-00151 Rome, Italy
关键词
voxel S values; Monte Carlo; electron; photon; internal dosimetry; DOSE-POINT KERNELS; MONTE-CARLO CODES; ABSORBED FRACTIONS; DOSIMETRY; RADIONUCLIDES; GEANT4; IMPLEMENTATION; DISTRIBUTIONS; VALIDATION; ACCURACY;
D O I
10.1118/1.4757912
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The use of voxel S values (VSVs) is perhaps the most common approach to radiation dosimetry for nonuniform distributions of activity within organs or tumors. However, VSVs are currently available only for a limited number of voxel sizes and radionuclides. The objective of this study was to develop a general method to evaluate them for any spectrum of electrons and photons in any cubic voxel dimension of practical interest for clinical dosimetry in targeted radionuclide therapy. Methods: The authors developed a Monte Carlo simulation in Geant4 in order to evaluate the energy deposited per disintegration (E-dep) in a voxelized region of soft tissue from monoenergetic electrons (10-2000 keV) or photons (10-1000 keV) homogeneously distributed in the central voxel, considering voxel dimensions ranging from 3 mm to 10 mm. E-dep was represented as a function of a dimensionless quantity termed the "normalized radius," R-n = R/l, where l is the voxel size and R is the distance from the origin. The authors introduced two parametric functions in order to fit the electron and photon results, and they interpolated the parameters to derive VSVs for any energy and voxel side within the ranges mentioned above. In order to validate the results, the authors determined VSV for two radionuclides (I-131 and Sr-89) and two voxel dimensions and they compared them with reference data. A validation study in a simple sphere model, accounting for tissue inhomogeneities, is presented. Results: The E-dep(R-n) for both monoenergetic electrons and photons exhibit a smooth variation with energy and voxel size, implying that VSVs for monoenergetic electrons or photons may be derived by interpolation over the range of energies and dimensions considered. By integration, S values for continuous emission spectra from beta(-) decay may be derived as well. Conclusions: The approach allows the determination of VSVs for monoenergetic (Auger or conversion) electrons and (x-ray or gamma-ray) photons by means of two functions whose parameters can be interpolated from tabular data provided. Through integration, it is possible to generalize the method to any continuous (beta) spectrum, allowing to calculate VSVs for any electron and photon emitter in a voxelized structure. (c) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4757912]
引用
收藏
页码:6808 / 6817
页数:10
相关论文
共 34 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]  
Amako K., 2004, NUCL PHYS B, V150, P44
[3]  
Amato E, 2011, Q J NUCL MED MOL IM, V55, P560
[4]   Absorbed fractions for electrons in ellipsoidal volumes [J].
Amato, E. ;
Lizio, D. ;
Baldari, S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (02) :357-365
[5]   Absorbed fractions for photons in ellipsoidal volumes [J].
Amato, E. ;
Lizio, D. ;
Baldari, S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (20) :N479-N487
[6]   Absorbed fractions in ellipsoidal volumes for β- radionuclides employed in internal radiotherapy [J].
Amato, E. ;
Lizio, D. ;
Baldari, S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (13) :4171-4180
[7]   A method to evaluate the dose increase in CT with iodinated contrast medium [J].
Amato, Ernesto ;
Lizio, Domenico ;
Settineri, Nicola ;
Di Pasquale, Andrea ;
Salamone, Ignazio ;
Pandolfo, Ignazio .
MEDICAL PHYSICS, 2010, 37 (08) :4249-4256
[8]  
Berger M., 2012, XCOM PHOTON CROSS SE
[9]  
Bolch WE, 1999, J NUCL MED, V40, p11S
[10]   Calculation of electron and isotopes dose point kernels with FLUKA Monte Carlo code for dosimetry in nuclear medicine therapy [J].
Botta, F. ;
Mairani, A. ;
Battistoni, G. ;
Cremonesi, M. ;
Di Dia, A. ;
Fasso, A. ;
Ferrari, A. ;
Ferrari, M. ;
Paganelli, G. ;
Pedroli, G. ;
Valente, M. .
MEDICAL PHYSICS, 2011, 38 (07) :3944-3954