Validation of three deformable image registration algorithms for the thorax

被引:28
|
作者
Latifi, Kujtim [2 ,4 ]
Zhang, Geoffrey [2 ,4 ]
Stawicki, Marnix [3 ]
van Elmpt, Wouter [3 ]
Dekker, Andre [3 ]
Forster, Kenneth [1 ]
机构
[1] Univ S Alabama, Dept Radiat Oncol, Mitchell Canc Inst, Mobile, AL 36604 USA
[2] Univ S Florida, H Lee Moffitt Canc Ctr, Div Radiat Oncol, Tampa, FL 33682 USA
[3] Maastricht Univ, Med Ctr, Dept Radiat Oncol MAASTRO, NL-6229 ET Maastricht, Netherlands
[4] Univ S Florida, Dept Phys, Tampa, FL 33620 USA
来源
关键词
DIR; image registration; deformable; validation; 4D CT; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; OPTICAL-FLOW METHOD; NONRIGID REGISTRATION; DEMONS ALGORITHM; CT IMAGES; VENTILATION; RADIOTHERAPY; SCANS;
D O I
10.1120/jacmp.v14i1.3834
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Deformable image registration (DIR) has been proposed for lung ventilation calculation using 4D CT. Spatial accuracy of DIR can be evaluated using expert landmark correspondences. Additionally, image differences between the deformed and the target images give a degree of accuracy of DIR algorithms for the same image modality registration. DIR of the normal end-expiration (50%), end-inspiration (0%), midexpiration (30%), and midinspiration image (70%) phases of the 4D CT images was used to correlate the voxels between the respiratory phases. Three DIR algorithms, optical flow (OF), diffeomorphic morphons (DM), and diffeomorphic demons (DD) were validated using a 4D thorax model, consisting of a 4D CT image dataset, along with associated landmarks delineated by a radiologist. Image differences between the deformed and the target images were used to evaluate the degree of registration accuracy of the three DIR algorithms. In the validation of the DIR algorithms, the average target registration error (TRE) for normal end-expiration-to-end-inspiration registration with one standard deviation (SD) for the DIR algorithms was 1.6 +/- 0.9 mm (maximum 3.1 mm) for OF, 1.4 +/- 0.6 mm (maximum 3.3 mm) for DM, and 1.4 +/- 0.7 mm (maximum 3.3 mm) for DD, indicating registration errors were within two voxels. As a reference, the median value of TRE between 0 and 50% phases with rigid registration only was 5.0 mm with one SD of 2.5 mm and the maximum value of 12.0 mm. For the OF algorithm, 81% of voxels were within a difference of 50 HU, and 93% of the voxels were within 100 HU. For the DM algorithm, 69% of voxels were within 50 HU, and 87% within 100 HU. For the DD algorithm, 71% of the voxels were within 50 HU, and 87% within a difference of 100 HU. These data suggest that the three DIR methods perform accurate registrations in the thorax region. The mean TRE for all three DIR methods was less than two voxels suggesting that the registration performed by all methods are equally accurate in the thorax.
引用
收藏
页码:19 / 30
页数:12
相关论文
共 50 条
  • [1] Development of a dynamic deformable thorax phantom for the quality management of deformable image registration
    Sugawara, Yasuharu
    Kadoya, Noriyuki
    Kotabe, Kazuki
    Nakajima, Yujiro
    Ikeda, Ryutaro
    Tanabe, Shunpei
    Ohashi, Haruna
    Jingu, Keiichi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 77 : 100 - 107
  • [2] Accuracy and limitations of deformable image registration with SmartAdapt® in the thorax region
    Sarudis, S.
    Hauer, A. Karlsson
    Bibac, D.
    Back, A.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S893 - S893
  • [3] Validation of biomechanical deformable image registration in the abdomen, thorax, and pelvis in a commercial radiotherapy treatment planning system
    Velec, Michael
    Moseley, Joanne L.
    Svensson, Stina
    Hardemark, Bjorn
    Jaffray, David A.
    Brock, Kristy K.
    MEDICAL PHYSICS, 2017, 44 (07) : 3407 - 3417
  • [4] Validation of Accuracy in Deformable Image Registration by Use of Three-Dimensional Phantom
    Kobayashi, M.
    Hayashi, N.
    Egami, K.
    Yasui, K.
    MEDICAL PHYSICS, 2018, 45 (06) : E228 - E228
  • [5] Evaluation of deformable image registration accuracy for CT images of the thorax region
    Sarudis, Sebastian
    Karlsson, Anna
    Bibac, Dan
    Nyman, Jan
    Back, Anna
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 57 : 191 - 199
  • [6] Validation of deformable image registration algorithms on CT images of ex vivo porcine bladders
    Heethuis, S. E.
    Wognum, S.
    Hoogeman, M. S.
    Bel, A.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S34 - S34
  • [7] Impact of CT scan parameters on deformable image registration accuracy using deformable thorax phantom
    Ikeda, Ryutaro
    Kadoya, Noriyuki
    Nakajima, Yujiro
    Ishii, Shin
    Shibu, Takayuki
    Jingu, Keiichi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (05):
  • [8] Intra and Intermodality Validation of Registration Algorithms On a Deformable Phantom
    Vincent, S. D.
    Archambault, L.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [9] Validation of Deformable Image Registration Algorithms for Head and Neck Adaptive Radiotherapy in Routine Clinical Setting
    Zhang, L.
    Wang, Z.
    Shi, C.
    Pi, Y.
    Long, T.
    Luo, W.
    Wang, F.
    Chen, Z.
    Xu, X.
    MEDICAL PHYSICS, 2016, 43 (06) : 3342 - 3342
  • [10] Recommendations for validation and verification of deformable image registration in radiotherapy
    Bosma, L.
    Hussein, M.
    Jameson, M.
    Asghar, S.
    Brock, K.
    McClelland, J.
    Poeta, S.
    Yuen, J.
    Zachiu, C.
    Yeo, A.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S505 - S506