Accuracy enhancement of magnetic field distribution measurements within a large cell spin-exchange relaxation-free magnetometer

被引:7
作者
Gusarov, Alexander [1 ,2 ]
Baranga, Andrei Ben-Amar [2 ]
Levron, David [2 ]
Shuker, Reuben [2 ]
机构
[1] Tamar Reg Council, Dead Sea & Arava Sci Ctr, IL-86910 Tamar, Israel
[2] Ben Gurion Univ Negev, Dept Phys, IL-84105 Beer Sheva, Israel
关键词
atomic magnetometer; SERF; 3D measurements; multifactorial design;
D O I
10.1088/1361-6501/aaa702
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The factorial design technique is implemented to achieve greater accuracy in the determination of magnetic field distribution within a single cell of spin-exchange relaxation-free atomic magnetometer. Three-dimensional magnetic field distribution within a single vapor cell can be found by consecutively pumping, layer by layer, all the cell volumes perpendicular to the probe laser beam, detected by a photodiode array. Thus each element of the array collects information about the magnetic field in the small volume (voxel) which forms when the corresponding part of the probe beam and optically pumped layer cross. One of the most effective ways to enhance measurement accuracy is repeated pumping of the layers and averaging the measured results. However, the measurement time is multiplied several times due to the repeated scanning of the cell volume. The suggested technique enables increased measurement accuracy of each voxel while preserving the number of measurements. Magnetic field distribution is determined by the illumination of the cell layers one by one or simultaneously, according to a special algorithm, with subsequent multifactorial analysis of the obtained results.
引用
收藏
页数:7
相关论文
共 33 条
  • [31] Examination of Spin-Exchange Relaxation in the Alkali Metal-Noble Gas Comagnetometer With a Large Electron Magnetic Field
    Jiang, Liwei
    Duan, Lihong
    Liu, Jiali
    Liang, Yixiang
    Quan, Wei
    Fang, Jiancheng
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [32] Enhancing the sensitivity of spin-exchange relaxation-free magnetometers using phase-modulated pump light with external Gaussian noise
    Ma, Ning
    Fang, Xiujie
    Zhang, Yaqi
    Xing, Bozheng
    Duan, Lihong
    Lu, Jixi
    Han, Bangcheng
    Ma, Danyue
    OPTICS EXPRESS, 2024, 32 (19): : 33378 - 33390
  • [33] Suppression of vapor cell temperature error for spin-exchange-relaxation-free magnetometer
    Lu, Jixi
    Qian, Zheng
    Fang, Jiancheng
    Quan, Wei
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (08)