Accuracy enhancement of magnetic field distribution measurements within a large cell spin-exchange relaxation-free magnetometer

被引:7
|
作者
Gusarov, Alexander [1 ,2 ]
Baranga, Andrei Ben-Amar [2 ]
Levron, David [2 ]
Shuker, Reuben [2 ]
机构
[1] Tamar Reg Council, Dead Sea & Arava Sci Ctr, IL-86910 Tamar, Israel
[2] Ben Gurion Univ Negev, Dept Phys, IL-84105 Beer Sheva, Israel
关键词
atomic magnetometer; SERF; 3D measurements; multifactorial design;
D O I
10.1088/1361-6501/aaa702
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The factorial design technique is implemented to achieve greater accuracy in the determination of magnetic field distribution within a single cell of spin-exchange relaxation-free atomic magnetometer. Three-dimensional magnetic field distribution within a single vapor cell can be found by consecutively pumping, layer by layer, all the cell volumes perpendicular to the probe laser beam, detected by a photodiode array. Thus each element of the array collects information about the magnetic field in the small volume (voxel) which forms when the corresponding part of the probe beam and optically pumped layer cross. One of the most effective ways to enhance measurement accuracy is repeated pumping of the layers and averaging the measured results. However, the measurement time is multiplied several times due to the repeated scanning of the cell volume. The suggested technique enables increased measurement accuracy of each voxel while preserving the number of measurements. Magnetic field distribution is determined by the illumination of the cell layers one by one or simultaneously, according to a special algorithm, with subsequent multifactorial analysis of the obtained results.
引用
收藏
页数:7
相关论文
共 33 条
  • [21] Single-beam triaxial spin-exchange relaxation-free atomic magnetometer utilizing transverse modulation fields
    Li, Lin
    Tang, Junjian
    Zhao, Binbin
    Cao, Li
    Zhou, Binquan
    Zhai, Yueyang
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2022, 55 (50)
  • [22] A polarization-improved dual-beam spin-exchange relaxation-free magnetometer with reflection-assisted pumping
    Huang, Binyue
    Liu, Ying
    Li, Renjie
    Li, Jiajie
    Tang, Junjian
    Zhai, Yueyang
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 375
  • [23] An all-optical scalar and vector spin-exchange relaxation-free magnetometer employing on-off pump modulation
    Gusarov, Alexander
    Levron, David
    Baranga, Andrei Ben-Amar
    Paperno, Eugene
    Shuker, Reuben
    JOURNAL OF APPLIED PHYSICS, 2011, 109 (07)
  • [24] An Integrated High-Sensitivity VCSEL-Based Spin-Exchange Relaxation-Free Magnetometer With Optical Rotation Detection
    Zhang, Guiying
    Zeng, Hongjian
    Tan, Gaobo
    Lin, Qiang
    IEEE SENSORS JOURNAL, 2022, 22 (08) : 7700 - 7708
  • [25] Application of spin-exchange relaxation-free magnetometry to the Cosmic Axion Spin Precession Experiment
    Wang, Tao
    Kimball, Derek F. Jackson
    Sushkov, Alexander O.
    Aybas, Deniz
    Blanchard, John W.
    Centers, Gary
    Kelley, Sean R. O'
    Wickenbrock, Arne
    Fang, Jiancheng
    Budker, Dmitry
    PHYSICS OF THE DARK UNIVERSE, 2018, 19 : 27 - 35
  • [26] Probe beam influence on spin polarization in spin-exchange relaxation-free co-magnetometers
    Wei, Yao
    Xing, Li
    Zhai, Yueyang
    Fan, Wenfeng
    Fang, Chi
    Liu, Feng
    Quan, Wei
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2023, 56 (13)
  • [27] Optimal buffer gas pressure in dual-beam spin-exchange relaxation-free magnetometers
    Lu, Jixi
    Zhang, Shaowen
    Zhou, Ying
    Yan, Yeguang
    Lu, Fei
    Wang, Kun
    Zhai, Yueyang
    Ye, Mao
    SENSORS AND ACTUATORS A-PHYSICAL, 2022, 347
  • [28] Suppression of spin-exchange relaxation in tilted magnetic fields within the geophysical range
    Scholtes, Theo
    Pustelny, Szymon
    Fritzsche, Stephan
    Schultze, Volkmar
    Stolz, Ronny
    Meyer, Hans-Georg
    PHYSICAL REVIEW A, 2016, 94 (01)
  • [29] In Situ Triaxial Magnetic Field Compensation for the Spin-Exchange-Relaxation-Free Optically Pumped Magnetometer
    Niu, Yaqiong
    Ye, Chaofeng
    IEEE SENSORS JOURNAL, 2023, 23 (18) : 21137 - 21146
  • [30] Active magnetic compensation of spin-exchange-relaxation-free atomic magnetometer
    Sun, X.-G. (136072016@163.com), 1808, Chinese Academy of Sciences (22): : 1808 - 1813